Malak Esseili

Dr. Malak Esseili

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2019 in Viruses
Verified
Journal Article
Open access
PDF file
MEMalak Esseili
Malak Esseili
XGXiang Gao
Xiang Gao
Patricia A. BoleyPatricia A. Boley
Patricia A. Boley
YHYixuan Hou
Yixuan Hou
LSLinda J. Saif
Linda J. Saif
Qiuhong WangQiuhong Wang
Qiuhong Wang
Lettuce is often implicated in human norovirus (HuNoV) foodborne outbreaks. We identified H-like histo-blood group antigens (HBGAs) on lettuce leaves as specific binding moieties for virus-like particles (VLPs) of HuNoV GII.4/HS194/2009 strain. The objective of this study was to determine whether HuNoV-lettuce binding is mediated through the virus HBGA binding sites (HBS). Toward this objective, VLPs of historical HuNoV GII.4 strains (1987, 1997, 2002, 2004 and 2006) with known natural mutations in their HBS, two newly generated VLP mutants of GII.4/HS194/2009 (D374A and G443A) and a VLP mutant (W375A) of GI.1/Norwalk/1968 along with its wild type VLPs, which displays distinct HBS, were investigated for their binding to lettuce. ELISA revealed that historical GII.4 strains binding to lettuce was dependent on their HBGAs profiles. The VLP mutants D374A and G443A lost binding to HBGAs and displayed no to minimal binding to lettuce, respectively. The VLPs of GI.1/Norwalk/1968 strain bound to lettuce through an H-like HBGA and the binding was inhibited by fucosidase digestion. Mutant W375A which was previously shown not to bind to HBGAs, displayed significantly reduced binding to lettuce. We conclude that the binding of HuNoV GII.4 and GI.1 strains to lettuce is mediated through the virus HBS.

21 June 2022 in Food Microbiology
Verified
Journal Article
Open access
MEMalak Esseili
Malak Esseili
AMAmy Mann
Amy Mann
RNRevati Narwankar
Revati Narwankar
IKIssmat Kassem
Issmat Kassem
FDFrancisco Diez-Gonzalez
Francisco Diez-Gonzalez
RHRobert J. Hogan
Robert J. Hogan
The potential transmission of SARS-CoV-2 via food has been controversial since the beginning of the COVID-19 pandemic. To investigate these concerns, reliable detection methods and data on virus die-off rates in various foods are needed. Here, an FDA-standard method for the detection of enteric viruses’ RNA from soft fruits was modified for the recovery of infectious SARS-CoV-2. Then, the survival of SARS-CoV-2 on berries was investigated as well as the effectiveness of washing virus-contaminated berries with water. The modified method did not significantly reduced log infectivity titers of recovered viruses, but berries did. The detection limit of the method for infectious SARS-CoV-2 was ∼2.97 log TCID50/g of berries. On SARS-CoV-2-inoculated berries that were stored at 4 °C for 7 days, significant reductions in SARS-CoV-2 infectivity were observed over time. In contrast, on frozen berries, infectious SARS-CoV-2 was recovered for 28 days without significant reductions. Washing SARS-CoV-2-inoculated berries with water removed >90% of infectious viruses within 10 min; however, infectious viruses were detected in wash water. Therefore, on fresh berries infectious viruses are markedly inactivated over time and can be largely removed by washing with water. However, the prolonged survival of SARS-CoV-2 on frozen berries suggests that the virus can potentially spread through frozen fruits.

8 August 2023 in Foods
Verified
Journal Article
Open access
PDF file
JMJulianna N. Morris
Julianna N. Morris
MEMalak Esseili
Malak Esseili
Sodium hypochlorite (NaOCl) and peracetic acid (PAA) are commonly used disinfectants with a maximum recommended concentration of 200 ppm for food-contact surfaces. The objectives of this study were to assess the effect of pH and water hardness on NaOCl and PAA efficacy against SARS-CoV-2 on stainless steel (SS). The two disinfectants were prepared at 200 ppm in water of hardness 150 or 300 ppm with the final pH adjusted to 5, 6, 7, or 8. Disinfectants were applied to virus-contaminated SS for one minute at room temperature following the ASTM E2197 standard assay. SARS-CoV-2 infectivity was quantified using TCID50 assay on Vero-E6 cells. In general, increasingly hard water decreased the efficacy of NaOCl while increasing the efficacy of PAA. Hard water at 300 ppm significantly increased virus log reduction with PAA at pH 8 by ~1.5 log. The maximum virus log reductions were observed at pH 5 for both NaOCl (~1.2 log) and PAA (~2 log) at 150 and 300 ppm hard water, respectively. In conclusion, PAA performed significantly better than NaOCl with harder water. However, both disinfectants at 200 ppm and one minute were not effective (≤3 log) against SARS-CoV-2 on contaminated food-contact surfaces, which may facilitate the role of these surfaces in virus transmission.

2 February 2024 in Viruses
Verified
Journal Article
Open access
PDF file
RNRevati Narwankar
Revati Narwankar
MEMalak Esseili
Malak Esseili
Human intestinal enteroids (HIEs) culture is an emerging model for assessing the infectivity of human noroviruses (HuNoVs). The model is based on detecting an increase in HuNoV RNA post-infection of HIEs. HuNoV fecal samples used for HIE infection are traditionally processed by serial filtration. Recently, processing HuNoV fecal samples by serial centrifugation was shown to retain vesicles containing HuNoV. The objective of this study was to investigate whether serially centrifuged fecal samples, RNA extraction kit (QIAamp versus MagMaX) and HIE age (newer versus older) affect HuNoV RNA fold increase in HIE. HuNoV GII.1, GII.4 and GII.6 fecal samples were prepared by serial centrifugation and filtration and the viral RNA in HIE was quantified at 1 and 72 h post-infection (hpi) following RNA extraction and RT-qPCR. The serially filtered GII.1, GII.4 and GII.6 showed successful replication in HIE, resulting in mean log increases of 2.2, 2 and 1.2, respectively, at 72 vs. 1 hpi. In contrast, only serially centrifuged GII.1 showed consistently successful replication. However, using newer HIE passages and the MagMAX kit resulted in mean log fold increases for serially centrifuged GII.1, GII.4 and GII.6 (1.6, 2.3 and 1.8 log, respectively) that were similar to serially filtered samples. Therefore, HuNoV fecal sample processing and HIE age can affect virus replication in the HIE model.

5 February 2025 in Science of The Total Environment
Verified
Journal Article
Closed access
MEMalak Esseili
Malak Esseili
RNRevati Narwankar
Revati Narwankar
RHRiya Hooda
Riya Hooda
VCVeronica Costantini
Veronica Costantini
MEMary K. Estes
Mary K. Estes
IKIssmat I. Kassem
Issmat I. Kassem

27 November 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
DKDilmeet Kaur
Dilmeet Kaur
MEMalak Esseili
Malak Esseili
Ramaraja P. RamasamyRamaraja P. Ramasamy
Ramaraja P. Ramasamy
Hepatitis A virus (HAV), a major cause of acute liver infections, is transmitted through the fecal–oral route and close contact with infected individuals. Current HAV standardized methods rely on the detection of virus antigen or RNA, which do not differentiate between infectious and non-infectious HAV. The objective of this study was to develop a prototype cell-based electrochemical biosensor for detection of infectious HAV. A cell culture-adapted HAV strain (HM175/18f) and its permissive cells (FRhK-4), along with gold nanoparticle-modified screen-printed electrodes, were used to develop the biosensor. Electrochemical impedance spectroscopy was used to quantify the electrical impedance signal. Nyquist plots showed successful fabrication of the cell-based biosensor. The optimum period of HAV incubation with the biosensor was 6 h. A significant linear relationship (R2 = 0.98) was found between the signal and a 6-log range of HAV titers, with a limit of detection of ~5 TCID50/mL (tissue culture infectious dose). The biosensor did not detect non-target viruses such as feline calicivirus and human coronavirus 229E. The biosensor was stable for 3 to 7 days at an abusive temperature (37 °C), retaining ~90 to 60% of the original signal, respectively. In conclusion, this prototype cell-based biosensor is capable of rapidly detecting low levels of infectious HAV.