Lorenzo Mannelli

Dr. Lorenzo Mannelli

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2009 in Radiology
Verified
Journal Article
Closed access
BTBachir Taouli
Bachir Taouli
RTRavi K. Thakur
Ravi K. Thakur
LMLorenzo Mannelli
Lorenzo Mannelli
JBJames S. Babb
James S. Babb
SKSooah Kim
Sooah Kim
GIGary M. Israel
Gary M. Israel
Purpose: To compare the diagnostic performance of diffusion-weighted (DW) magnetic resonance (MR) imaging with that of contrast material–enhanced (CE) MR imaging and to assess the performance of these examinations combined for the characterization of renal lesions, with MR follow-up and histopathologic analysis as the reference standards. Materials and Methods: The institutional review board waived the requirement of informed patient consent for this retrospective HIPAA-compliant study. One hundred nine renal lesions in 64 patients (46 men, 18 women; mean age, 60.7 years) were evaluated with CE MR imaging and breath-hold DW imaging performed with various b values. Renal lesions were characterized with use of CE MR criteria, and apparent diffusion coefficients (ADCs) were measured. The ADCs of benign and malignant lesions were compared at Mann-Whitney testing. Receiver operating characteristic (ROC) analysis was performed to assess the accuracy of DW imaging and CE MR imaging in the diagnosis of renal cell...

1 October 2009 in American Journal of Roentgenology
Verified
Journal Article
Closed access
LMLorenzo Mannelli
Lorenzo Mannelli
SKSooah Kim
Sooah Kim
CHCristina H. Hajdu
Cristina H. Hajdu
JBJames S. Babb
James S. Babb
TCTimothy W. I. Clark
Timothy W. I. Clark
BTBachir Taouli
Bachir Taouli
OBJECTIVE. The purpose of this study was to compare, with histopathologic examination of the liver explant as the reference standard, diffusion-weighted MRI with contrast-enhanced subtraction MRI in the assessment of necrosis of hepatocellular carcinoma (HCC) after trans arterial chemoembolization (TACE).MATERIALS AND METHODS. The cases of 21 patients with HCC who underwent MRI after TACE were evaluated. Two independent observers calculated the apparent diffusion coefficient (ADC) of HCC and measured percentage tumor necrosis on subtraction images. The ADCs of necrotic and viable tumor tissues were compared. ADC and percentage necrosis on subtraction images were correlated with percentage necrosis found at pathologic examination. Receiver operating characteristics analysis was performed on the diagnosis of complete tumor necrosis.RESULTS. Twenty-eight HCCs (mean diameter, 2.3 cm) were evaluated. There were significant differences between the ADC of viable tissue and that of necrotic tumor tissue (1.33 ± 0...

3 August 2013 in CardioVascular and Interventional Radiology
Verified
Journal Article
Closed access
PDF file
Luca SabaLuca Saba
Luca Saba
MAMichele Anzidei
Michele Anzidei
BMBeatrice Cavallo Marincola
Beatrice Cavallo Marincola
MPMario Piga
Mario Piga
EREytan Raz
Eytan Raz
MWMax Wintermark
Max Wintermark

28 February 2012 in Hepatology
Verified
Journal Article
Open access
PDF file
MPMi-Suk Park
Mi-Suk Park
SKSooah Kim
Sooah Kim
JPJignesh Patel
Jignesh Patel
CHCristina H. Hajdu
Cristina H. Hajdu
RDRichard K. G. Do
Richard K. G. Do
BTBachir Taouli
Bachir Taouli
This study evaluates the performance of diffusion-weighted magnetic resonance imaging (DWI) for the detection of hepatocellular carcinoma (HCC) in pre–liver transplantation patients, compared and combined with contrast-enhanced T1-weighted imaging (CET1WI), using liver explant as the standard of reference. We included 52 patients with cirrhosis (40 men, 12 women; mean age, 56 years) who underwent DWI and CET1WI within 90 days of liver transplantation. Magnetic resonance images were analyzed for HCC detection in three separate sessions by two independent observers: DWI images (DW-set), CET1WI (CE-set), and all images together (All-set). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), per-patient accuracy, and per-lesion PPV were calculated for each image set. A total of 72 HCCs were present in 33 patients at explant (mean size, 1.5 cm [range, 0.3-6.2 cm]). Per-patient sensitivity and NPV of CE-set were significantly higher than those of DW-set when using pooled data between observers (P = 0.02 and 0.03, respectively), whereas specificity, PPV, and accuracy were equivalent. Per-lesion sensitivity was significantly higher for CE-set versus DW-set (59.0% versus 43.8%; P = 0.008, pooled data from two observers). When stratified by lesion size, the difference was significant only for lesions with a size between 1 and 2 cm (42.0% for DW-set versus 74.0% for CE-set; P = 0.001). The addition of DWI to CET1WI improved sensitivity for the more experienced observer. Conclusion: DWI is outperformed by CET1WI for detection of HCC, but represents a reasonable alternative to CET1WI for detection of HCC with a size above 2 cm. The addition of DWI to CET1WI slightly increases the detection rate. (HEPATOLOGY 2012;56:140–148)

11 February 2010 in European Radiology
Verified
Journal Article
Closed access
PDF file
AHAndrew D. Hardie
Andrew D. Hardie
MNMohit Naik
Mohit Naik
EHElizabeth M. Hecht
Elizabeth M. Hecht
HCHersh Chandarana
Hersh Chandarana
LMLorenzo Mannelli
Lorenzo Mannelli
BTBachir Taouli
Bachir Taouli

1 September 2013 in Current Problems in Diagnostic Radiology
Verified
Journal Article
Closed access
SOSherif Osman
Sherif Osman
BLBruce E. Lehnert
Bruce E. Lehnert
SESaeed Elojeimy
Saeed Elojeimy
ICIrene Cruite
Irene Cruite
LMLorenzo Mannelli
Lorenzo Mannelli
MMMariam Moshiri
Mariam Moshiri