Roberto Rongo

Dr. Roberto Rongo

Department of Neuroscience, Reproductive Sciences and Oral Sciences, University of Naples “Federico II”, 80138 Naples, Italy
+1
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2024 in Cranio®
Verified
Journal Article
Open access
DMDaniele Manfredini
Daniele Manfredini
BHBirgitta Haggman-Henrikson
Birgitta Haggman-Henrikson
AJAhmad Al Jagshi
Ahmad Al Jagshi
LBLene Baad-Hansen
Lene Baad-Hansen
EBEmma Beecroft
Emma Beecroft
IMInternational Network for Orofacial Pain and Related Disorders Methodology
International Network for Orofacial Pain and Related Disorders Methodology
To present a list of key points for good Temporomandibular Disorders (TMDs) clinical practice on behalf of the International Network for Orofacial Pain and Related Disorders Methodology (INfORM) group of the International Association for Dental, Oral and Craniofacial Research (IADR). An open working group discussion was held at the IADR General Session in New Orleans (March 2024), where members of the INfORM group finalized the proposal of a list of 10 key points. The key points covered knowledge on the etiology, diagnosis, and treatment. They represent a summary of the current standard of care for management of TMD patients. They are in line with the current need to assist general dental practitioners advance their understanding and prevent inappropriate treatment. The key points can be viewed as a guiding template for other national and international associations to prepare guidelines and recommendations on management of TMDs adapted to the different cultural, social, educational, and healthcare requirements.

23 March 2016 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PDF file
Rosaria BucciRosaria Bucci
Rosaria Bucci
Vincenzo D'AntòVincenzo D'Antò
Vincenzo D'Antò
Roberto RongoRoberto Rongo
Roberto Rongo
Rosa VallettaRosa Valletta
Rosa Valletta
RMR. Martina
R. Martina
AMAmbra Michelotti
Ambra Michelotti

9 September 2019 in Progress in Orthodontics
Verified
Journal Article
Open access
PDF file
Rosaria BucciRosaria Bucci
Rosaria Bucci
Roberto RongoRoberto Rongo
Roberto Rongo
CLCarmine Levatè
Carmine Levatè
AMAmbra Michelotti
Ambra Michelotti
SBSandro Barone
Sandro Barone
Vincenzo D'AntòVincenzo D'Antò
Vincenzo D'Antò
Background: Clear aligners (CA) are among the most chosen orthodontic therapies for patients who require an invisible treatment. Previous studies showed that the thermoforming process and the complexity of the intraoral environment might alter the properties of these devices. The aim of the current prospective clinical study was to assess the thickness changes of the CA after 10 days of intraoral use. The secondary aim was to assess the reproducibility of the thermoforming process, in terms of aligner thickness. Materials and methods: CA from 18 consecutive patients (13 women, 5 men, mean age 28.8 ± 9.6 years) were investigated. Before intraoral exposure (T0), the thickness of the unused CA was measured at different occlusal points on a 3D model with a dedicated software (Geomagic Qualify 2013; 3D Systems, Rock Hill, SC, USA). Two CA configurations were studied: passive maxillary aligner (P—no tooth movement; no shape for attachments) and active maxillary aligner (A—tooth movement; shape for attachments and divot). The used aligners were returned after 10 days (T1) and the thickness measurements were repeated. A Student’s t test for paired data (T1 vs. T0) was applied to compare the thicknesses of used and unused devices (significance level after Bonferroni correction for multiple comparison was set at p < 0.0014). Furthermore, to study the reproducibility of the thermoforming process, P and A aligners were thermoformed twice, and the thicknesses of the two unused thermoformed devices were compared by means of Student’s t test for paired data (significance level after Bonferroni correction for multiple comparison was set at p < 0.0014) and Dahlberg’s error. Results: The thermoforming process showed good reproducibility for both aligner configurations, with a maximum Dahlberg’s error of 0.13 mm. After intraoral use, the thickness of P showed some statistically significant, but not clinically relevant, thickness changes as compared to the unused aligners, while A did not show any significant changes. Conclusion: Considering the thickness changes, the thermoforming process is reliable both with active and passive aligner configurations. Also, the CA examined show good thickness stability after physiological intraoral ageing in a population of healthy adults.

5 April 2021 in Journal of Oral Rehabilitation
Verified
Journal Article
Open access
PDF file
Roberto RongoRoberto Rongo
Roberto Rongo
EEEwaCarin Ekberg
EwaCarin Ekberg
INIng‐Marie Nilsson
Ing‐Marie Nilsson
AAAmal Al‐Khotani
Amal Al‐Khotani
PAPer Alstergren
Per Alstergren
AMAmbra Michelotti
Ambra Michelotti
Background: Since in children and adolescence prevalence is assessed mainly on self‐reported or proxy‐reported signs and symptoms; there is a need to develop a more comprehensive standardised process for the collection of clinical information and the diagnosis of TMD in these populations.Objective: To develop new instruments and to adapt the diagnostic criteria for temporomandibular disorders (DC/TMD) for the evaluation of TMD in children and adolescents.Method: A modified Delphi method was used to seek international consensus among TMD experts. Fourteen clinicians and researchers in the field of oro‐facial pain and TMD worldwide were invited to participate in a workshop initiated by the International Network for Orofacial Pain and Related Disorders Methodology (INfORM scientific network) at the General Session of the International Association for Dental Research (IADR, London 2018), as the first step in the Delphi process. Participants discussed the protocols required to make physical diagnoses included in the Axis I of the DC/TMD. Thereafter, nine experts in the field were added, and the first Delphi round was created. This survey included 60 statements for Axis I, and the experts were asked to respond to each statement on a five‐item Likert scale ranging from ‘Strongly disagree’ to ‘Strongly agree’. Consensus level was set at 80% agreement for the first round, and at 70% for the next.Results: After three rounds of the Delphi process, a consensus among TMD experts was achieved and two adapted DC/TMD protocols for Axis I physical diagnoses for children and adolescents were developed.Conclusion: Through international consensus among TMD experts, this study adapted the Axis I of the DC/TMD for use in evaluating TMD in children and adolescents.

31 March 2015 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PDF file
Vincenzo D'AntòVincenzo D'Antò
Vincenzo D'Antò
Rosaria BucciRosaria Bucci
Rosaria Bucci
LFLorenzo Franchi
Lorenzo Franchi
Roberto RongoRoberto Rongo
Roberto Rongo
AMAmbra Michelotti
Ambra Michelotti
RMR. Martina
R. Martina

1 September 2012 in The Angle Orthodontist
Verified
Journal Article
Closed access
Vincenzo D'AntòVincenzo D'Antò
Vincenzo D'Antò
Roberto RongoRoberto Rongo
Roberto Rongo
GAGianluca Ametrano
Gianluca Ametrano
Gianrico SpagnuoloGianrico Spagnuolo
Gianrico Spagnuolo
PMPaolo Manzo
Paolo Manzo
RVRosa Valletta
Rosa Valletta
Objective: To compare the surface roughness of different orthodontic archwires. Materials and Methods: Four nickel-titanium wires (Sentalloy®, Sentalloy® High Aesthetic, Titanium Memory ThermaTi Lite®, and Titanium Memory Esthetic®), three β-titanium wires (TMA®, Colored TMA®, and Beta Titanium®), and one stainless-steel wire (Stainless Steel®) were considered for this study. Three samples for each wire were analyzed by atomic force microscopy (AFM). Three-dimensional images were processed using Gwiddion software, and the roughness average (Ra), the root mean square (Rms), and the maximum height (Mh) values of the scanned surface profile were recorded. Statistical analysis was performed by one-way analysis of variance (ANOVA) followed by Tukey's post hoc test ( P < .05). Results: The Ra, Rms, and Mh values were expressed as the mean ± standard deviation. Among as-received archwires, the Stainless Steel (Ra = 36.6 ± 5.8; Rms = 48 ± 7.7; Mh = 328.1 ± 64) archwire was less rough than the others (ANOVA, P < .05). The Sentalloy High Aesthetic was the roughest (Ra = 133.5 ± 10.8; Rms = 165.8 ± 9.8; Mh = 949.6 ± 192.1) of the archwires. Conclusions: The surface quality of the wires investigated differed significantly. Ion implantation effectively reduced the roughness of TMA. Moreover, Teflon®-coated Titanium Memory Esthetic was less rough than was ion-implanted Sentalloy High Aesthetic.