Mingxi Wan

Mingxi Wan


Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2019 in Advanced Healthcare Materials
Verified
Journal Article
Closed access
PDF file
PWPengying Wu
Pengying Wu
WDWei Dong
Wei Dong
XGXuyan Guo
Xuyan Guo
XQXiaoyang Qiao
Xiaoyang Qiao
SGShifang Guo
Shifang Guo
YZYujin Zong
Yujin Zong

1 June 2012 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
SZSiyuan Zhang
Siyuan Zhang
FZFanyu Zhou
Fanyu Zhou
MWMingxi Wan
Mingxi Wan
MWMin Wei
Min Wei
QFQuanyou Fu
Quanyou Fu
SWSupin Wang
Supin Wang
The acoustic posterior shadowing effects of bubbles influence the accuracy for defining the location and range of ablated thermal lesions during focused ultrasound surgery when using ultrasonic monitoring imaging. This paper explored the feasibility of using Nakagami distribution to evaluate the ablated region induced by focused ultrasound exposures at different acoustic power levels in transparent tissue-mimicking phantoms. The mean value of the Nakagami parameter m was about 0.5 in the cavitation region and increased to around 1 in the ablated region. Nakagami images were not subject to significant shadowing effects of bubbles. Ultrasound-induced thermal lesions observed in the photos and Nakagami images were overshadowed by bubbles in the B-mode images. The lesion size predicted in the Nakagami images was smaller than that predicted in the photos due to the sub resolvable effect of Nakagami imaging at the interface. This preliminary study on tissue-mimicking phantom suggested that the Nakagami parameter m may have the potential use in evaluating the formation of ultrasound-induced thermal lesion when the shadowing effect of bubbles is strong while the thermal lesion was small. Further studies in vivo and in vitro will be needed to evaluate the potential application. (C) 2012 Acoustical Society of America. [http://dx.doi.org/10.1121/1.4711005]

1 December 2022 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
SGShifang Guo
Shifang Guo
ZYZhen Ya
Zhen Ya
PWPengying Wu
Pengying Wu
MWMingxi Wan
Mingxi Wan
Acoustic vortices provide a single-beam approach to manipulate objects with sizes from nanometers to millimeters, gaining increasing interest in recent years. The helical beam renders them good ability to trap particles in three dimensions stably. At the same time, the orbital angular momentum of acoustic vortices can be used to realize object rotation and data transmission. In this review, we summarize the generation and characterization of acoustic vortices. Furthermore, we present the application of acoustic vortices in particle manipulation, object rotation, acoustic communication, and especially in the biomedical field. Finally, perspectives on the future directions for acoustic vortex research are discussed.

4 December 2019 in European Thyroid Journal
Verified
Journal Article
Closed access
PDF file
LXLei Xu
Lei Xu
JGJunling Gao
Junling Gao
QWQuan Wang
Quan Wang
JYJichao Yin
Jichao Yin
PYPengfei Yu
Pengfei Yu
MWMingxi Wan
Mingxi Wan
Background: Computer-aided diagnosis (CAD) systems are being applied to the ultrasonographic diagnosis of malignant thyroid nodules, but it remains controversial whether the systems add any accuracy for radiologists. Objective: To determine the accuracy of CAD systems in diagnosing malignant thyroid nodules. Methods: PubMed, EMBASE, and the Cochrane Library were searched for studies on the diagnostic performance of CAD systems. The diagnostic performance was assessed by pooled sensitivity and specificity, and their accuracy was compared with that of radiologists. The present systematic review was registered in PROSPERO (CRD42019134460). Results: Nineteen studies with 4,781 thyroid nodules were included. Both the classic machine learning- and the deep learning-based CAD system had good performance in diagnosing malignant thyroid nodules (classic machine learning: sensitivity 0.86 [95% CI 0.79–0.92], specificity 0.85 [95% CI 0.77–0.91], diagnostic odds ratio (DOR) 37.41 [95% CI 24.91–56.20]; deep learning: sensitivity 0.89 [95% CI 0.81–0.93], specificity 0.84 [95% CI 0.75–0.90], DOR 40.87 [95% CI 18.13–92.13]). The diagnostic performance of the deep learning-based CAD system was comparable to that of the radiologists (sensitivity 0.87 [95% CI 0.78–0.93] vs. 0.87 [95% CI 0.85–0.89], specificity 0.85 [95% CI 0.76–0.91] vs. 0.87 [95% CI 0.81–0.91], DOR 40.12 [95% CI 15.58–103.33] vs. DOR 44.88 [95% CI 30.71–65.57]). Conclusions: The CAD systems demonstrated good performance in diagnosing malignant thyroid nodules. However, experienced radiologists may still have an advantage over CAD systems during real-time diagnosis.

1 June 2010 in Journal of Ultrasound in Medicine
Verified
Journal Article
Closed access
PDF file
YFYi Feng
Yi Feng
ZTZhongmin Tian
Zhongmin Tian
MWMingxi Wan
Mingxi Wan

1 December 2016 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
LZLu Zhao
Lu Zhao
Yi FengYi Feng
Yi Feng
HHHong Hu
Hong Hu
ASAiwei Shi
Aiwei Shi
LZLei Zhang
Lei Zhang
MWMingxi Wan
Mingxi Wan