Paula Faria

Prof. Paula Faria

Centre for Rapid and Sustainable Product Development (CDRSP), Polytechnic Institute of Leiria (IPLeiria), Marinha Grande, Portugal
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2011 in Journal of Neural Engineering
Verified
Journal Article
Closed access
Paula FariaPaula Faria
Paula Faria
MHMark Hallett
Mark Hallett
PMPedro Cavaleiro Miranda
Pedro Cavaleiro Miranda
We investigated the effect of electrode area and inter-electrode distance on the spatial distribution of the current density in transcranial direct current stimulation (tDCS). For this purpose, we used the finite element method to compute the distribution of the current density in a four-layered spherical head model using various electrode montages, corresponding to a range of electrode sizes and inter-electrode distances. We found that smaller electrodes required slightly less current to achieve a constant value of the current density at a reference point on the brain surface located directly under the electrode center. Under these conditions, smaller electrodes also produced a more focal current density distribution in the brain, i.e. the magnitude of the current density fell more rapidly with distance from the reference point. The combination of two electrodes with different areas produced an asymmetric current distribution that could lead to more effective and localized neural modulation under the smaller electrode than under the larger one. Focality improved rapidly with decreasing electrode size when the larger electrode sizes were considered but the improvement was less marked for the smaller electrode sizes. Also, focality was not affected significantly by inter-electrode distance unless two large electrodes were placed close together. Increasing the inter-electrode distance resulted in decreased shunting of the current through the scalp and the cerebrospinal fluid, and decreasing electrode area resulted in increased current density on the scalp under the edges of the electrode. Our calculations suggest that when working with conventional electrodes (25-35 cm(2)), one of the electrodes should be placed just 'behind' the target relative to the other electrode, for maximum current density on the target. Also electrodes with areas in the range 3.5-12 cm(2) may provide a better compromise between focality and current density in the scalp than the traditional electrodes. Finally, the use of multiple small return electrodes may be more efficient than the use of a single large return electrode.

1 June 2009 in Clinical Neurophysiology
Verified
Journal Article
Closed access
PMPedro Cavaleiro Miranda
Pedro Cavaleiro Miranda
Paula FariaPaula Faria
Paula Faria
MHMark Hallett
Mark Hallett

7 December 2020 in Chemistry – A European Journal
Verified
Journal Article
Closed access
PDF file
LSLuciano De Sio
Luciano De Sio
BDBin Ding
Bin Ding
Monica FocsanMonica Focsan
Monica Focsan
Karin KogermannKarin Kogermann
Karin Kogermann
Paula FariaPaula Faria
Paula Faria
FPFilippo Pierini
Filippo Pierini

1 November 2012 in Epilepsy & Behavior
Verified
Journal Article
Closed access
Paula FariaPaula Faria
Paula Faria
Felipe FregniFelipe Fregni
Felipe Fregni
Fernando SebastiãoFernando Sebastião
Fernando Sebastião
ADAna I. Dias
Ana I. Dias
ALAlberto Leal
Alberto Leal

1 January 2014 in Procedia Technology
Verified
Journal Article
Open access
ADA. Duarte
A. Duarte
LCL. Carrão
L. Carrão
MEM. Espanha
M. Espanha
TVT. Viana
T. Viana
DFDino Freitas
Dino Freitas
HAH.A. Almeida
H.A. Almeida

28 August 2014 in Pain Practice
Verified
Journal Article
Closed access
PDF file
Paula FariaPaula Faria
Paula Faria
NYNilufer Yalcin
Nilufer Yalcin
Felipe FregniFelipe Fregni
Felipe Fregni