Michelangelo Guaitolini

Michelangelo Guaitolini

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MGMichelangelo Guaitolini
Michelangelo Guaitolini
Fitsum E. PetrosFitsum E. Petros
Fitsum E. Petros
APAntonio Prado
Antonio Prado
Angelo Maria SabatiniAngelo Maria Sabatini
Angelo Maria Sabatini
SASunil K. Agrawal
Sunil K. Agrawal
Ageing, disease, and injuries result in movement defects that affect daily life. Gait analysis is a vital tool for understanding and evaluating these movement dysfunctions. In recent years, the use of virtual reality (VR) to observe motion and offer augmented clinical care has increased. Although VR-based methodologies have shown benefits in improving gait functions, their validity against more traditional methods (e.g., cameras or instrumented walkways) is yet to be established. In this work, we propose a procedure aimed at testing the accuracy and viability of a VIVE Virtual Reality system for gait analysis. Seven young healthy subjects were asked to walk along an instrumented walkway while wearing VR trackers. Heel strike (HS) and toe off (TO) events were assessed using the VIVE system and the instrumented walkway, along with stride length (SL), stride time (ST), stride width (SW), stride velocity (SV), and stance/swing percentage (STC, SWC%). Results from the VR were compared with the instrumented walkway in terms of detection offset for time events and root mean square error (RMSE) for gait features. An absolute offset between VR- and walkway-based data of (15.3 ± 12.8) ms for HS, (17.6 ± 14.8) ms for TOs and an RMSE of 2.6 cm for SW, 2.0 cm for SL, 17.4 ms for ST, 2.2 m/s for SV, and 2.1% for stance and swing percentage were obtained. Our findings show VR-based systems can accurately monitor gait while also offering new perspectives for VR augmented analysis.

2 October 2018 in Technologies
Verified
Journal Article
Open access
PDF file
VGVincenzo Genovese
Vincenzo Genovese
Andrea ManniniAndrea Mannini
Andrea Mannini
MGMichelangelo Guaitolini
Michelangelo Guaitolini
ASAngelo Maria Sabatini
Angelo Maria Sabatini
Falls are one of the most common causes of accidental injury: approximately, 37.3 million falls requiring medical intervention occur each year. Fall-related injuries may cause disabilities, and in some extreme cases, premature death among older adults, which has a significant impact on health and social care services. In recent years, information and communication technologies (ICT) have helped enhance the autonomy and quality of life of elderly people, and significantly reduced the costs associated with elderly care. We designed and developed an integrated fall detection and prevention ICT service for elderly people, which was based on two wearable smart sensors, called, respectively, WIMU fall detector and WIMU data-logger (Wearable Inertial Measurement Unit, WIMU); their goal was either to detect falls and promptly react in case of fall events, or to quantify fall risk instrumentally. The WIMU fall detector is intended to be worn at the waist level for use during activities of daily living; the WIMU logger is intended for the quantitative assessment of tested individuals during the execution of clinical tests. Both devices provide their service in conjunction with an Android mobile device. The ICT service was developed and tested within the European project I-DONT-FALL (Integrated prevention and Detection sOlutioNs Tailored to the population and risk factors associated with FALLs, funded by EU, action EU CIP-ICT-PSP-2011-5: GA #CIP-297225). Sensor description and preliminary testing results are provided in this paper.

24 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
LTLuigi Truppa
Luigi Truppa
MGMichelangelo Guaitolini
Michelangelo Guaitolini
PGPietro Garofalo
Pietro Garofalo
CCCarlo Castagna
Carlo Castagna
Andrea ManniniAndrea Mannini
Andrea Mannini
Quantifying muscle fatigue is a key aspect of everyday sport practice. A reliable and objective solution that can fulfil this task would be deeply important for two main reasons: (i) it would grant an objective indicator to adjust the daily training load for each player and (ii) it would provide an innovative tool to reduce the risk of fatigue-related injuries. Available solutions for objectively quantifying the fatigue level of fatigue can be invasive for the athlete; they could alter the performance or they are not compatible with daily practice on the playground. Building on previous findings that identified fatigue-related parameters in the kinematic of the counter-movement jump (CMJ), this study evaluates the physical response to a fatigue protocol (i.e., Yo-Yo Intermittent Recovery Test Level 1) in 16 football referees, by monitoring CMJ performance with wearable magneto-inertial measurement units (MIMU). Nineteen kinematic parameters were selected as suitable indicators for fatigue detection. The analysis of their variations allowed us to distinguish two opposites but coherent responses to the fatigue protocol. Indeed, eight out of sixteen athletes showed reduced performance (e.g., an effective fatigue condition), while the other eight athletes experienced an improvement of the execution likely due to the so-called Post-Activation Potentiation. In both cases, the above parameters were significantly influenced by the fatigue protocol (p < 0.05), confirming their validity for fatigue monitoring. Interesting correlations between several kinematic parameters and muscular mass were highlighted in the fatigued group. Finally, a “fatigue approximation index” was proposed and validated as fatigue quantifier.

23 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MGMichelangelo Guaitolini
Michelangelo Guaitolini
FAFederica Aprigliano
Federica Aprigliano
Andrea ManniniAndrea Mannini
Andrea Mannini
SMSilvestro Micera
Silvestro Micera
VMVito Monaco
Vito Monaco
Angelo Maria SabatiniAngelo Maria Sabatini
Angelo Maria Sabatini
Loss of stability is a precursor to falling and therefore represents a leading cause of injury, especially in fragile people. Thus, dynamic stability during activities of daily living (ADLs) needs to be considered to assess balance control and fall risk. The dynamic margin of stability (MOS) is often used as an indicator of how the body center of mass is located and moves relative to the base of support. In this work, we propose a magneto-inertial measurement unit (MIMU)-based method to assess the MOS of a gait. Six young healthy subjects were asked to walk on a treadmill at different velocities while wearing MIMUs on their lower limbs and pelvis. We then assessed the MOS by computing the lower body displacement with respect to the leading inverse kinematics approach. The results were compared with those obtained using a camera-based system in terms of root mean square deviation (RMSD) and correlation coefficient (ρ). We obtained a RMSD of ≤1.80 cm and ρ ≥ 0.85 for each walking velocity. The findings revealed that our method is comparable to camera-based systems in terms of accuracy, suggesting that it may represent a strategy to assess stability during ADLs in unstructured environments.

16 October 2018
Verified
Book Chapter
Closed access
PDF file
MGMichelangelo Guaitolini
Michelangelo Guaitolini
FAF. Aprigliano
F. Aprigliano
Andrea ManniniAndrea Mannini
Andrea Mannini
ASA. M. Sabatini
A. M. Sabatini
VMV. Monaco
V. Monaco