Purpose : To evaluate the cumulative dose at point A for three and four centimeters central shielding. Material and methods: The plans of external beam radiotherapy plus conventional intracavitary brachytherapy were performed. Three or four centimeters central shieldings (after 44 Gy)...
20 July 2024 in Journal of Applied Clinical Medical Physics
Purpose: This study aims to introduce modified fixed field volumetric modulated arc therapy (MF‐VMAT) which manually opened the field size by fixing the jaws and comparing it to the typical planning technique, auto field volumetric modulated arc therapy (AF‐VMAT) in cervical cancer treatment planning.Methods and materials: Previously treated twenty‐eight cervical cancer plans were retrospectively randomly selected and replanned in this study using two different planning techniques: AF‐VMAT and MF‐VMAT, resulting in a total of fifty‐six treatment plans. In this study, we compared both planning techniques in three parts: (1) Organ at Risk (OARs) and whole‐body dose, (2) Treatment plan efficiency, and (3) Treatment plan accuracy.Results: For OARs dose, bowel bag (p‐value = 0.001), rectum (p‐value = 0.002), and left femoral head (p‐value = 0.001) and whole‐body (p‐value = 0.000) received a statistically significant dose reduction when using the MF‐VMAT plan. Regarding plan efficiency, MF‐VMAT exhibited a statistically significant increase in both number of monitor units (MUs) and control points (p‐values = 0.000), while beam‐on time, maximum leaf travel, average maximum leaf travel, and maximum leaf travel per gantry rotation were statistically significant decreased (p‐values = 0.000). In terms of plan accuracy, the average gamma passing rate was higher in the MF‐VMAT plan for both absolute dose (AD) (p‐value = 0.001, 0.004) and relative dose (RD) (p‐value = 0.000, 0.000) for 3%/3 and 3%/2 mm gamma criteria, respectively.Conclusion: The MF‐VMAT planning technique significantly reduces OAR doses and decreases the spread of low doses to normal tissues in cervical cancer patients. Additionally, this planning approach demonstrates efficient plans with lower beam‐on time and reduced maximum leaf travel. Furthermore, it indicates higher plan accuracy through an increase in the average gamma passing rate compared to the AF‐VMAT plan. Consequently, MF‐VMAT offers an effective treatment planning technique for cervical cancer patients.
1 March 2023 in Journal of Applied Clinical Medical Physics
Purpose: Stereotactic ablative body radiotherapy (SABR) in the liver, RTOG‐1112 guides the treatment modalities including the dose constraints for this technique but not the plan parameters. This study is not only analyzing the plan quality by utilizing the plan parameters and indexes but also compares treatment modalities from the protocol implementation.Method and material: Twenty‐five patients treated in the period from February 2020 to September 2022 were recruited in this analysis. Two planners randomly selected the patients and modalities. The modalities employed were Volumetric‐Modulated Arc Therapy (VMAT) and Helical Tomotherapy (HT). Various parameters and indexes were used to access not only the plan quality but also to compare each modality. The parameters and indexes studied were the homogeneity index (HI), conformity index (CI), gradient distance (GD), and the dose received by the organs at risk.Result: The data reveals that the mean volume of PTV is 60.8 ± 53.9 cc where these targets exhibit no significant difference between each modality. The HI shows a consistent value for both modalities. Between each modality, the CI value shows less deviation, but the HT shows slightly higher performance than VMAT. The value of GD is 1.5 ± 0.3 cm where the HT provides a shorter distance compared to VMAT as well.Conclusion: The parameters and indexes should be utilized for the plan evaluation although in the guidelines this was not required. Various modalities were employed for treatment. Both can achieve the treatment criteria with slightly low performance of VMAT.
Currently, advanced RT techniques such as VMAT and HT are being developed to optimize tumor coverage while minimizing radiation exposure to the surrounding organs that are at risk. Despite their growing clinical use, comparative studies evaluating the dosimetric and radiobiological effects of these modalities remain limited. In this study, A549, HeLa, and HepG2 cells were exposed to a single 2 Gy dose, using three RT techniques (3D-CRT, dual arc VMAT, and HT). Treatment plans were generated using a water phantom to ensure consistent target coverage and comparable dosimetric parameters across the techniques. Multiple radiobiological endpoints were assessed to evaluate the cellular responses. Although all three techniques yielded similar dosimetric parameters without statistically significant differences, the biological responses varied among the cell lines. Notably, VMAT and HT demonstrated superior tumor cell suppression compared to 3D-CRT. This was likely due to their enhanced dose conformity and modulation precision, which potentially led to improved tumor cell killing. These findings highlight the importance of integrating radiobiological assessments with physical dose metrics to inform the clinical application of advanced RT technologies. However, this study had several limitations. The use of a single radiation dose limited its clinical relevance, and the immediate post-irradiation assessments may not have captured delayed biological responses. Additionally, the small number of replicates may have reduced the study’s statistical power. Future studies incorporating dose fractionation schemes, time course analyses, and larger sample sizes are warranted to better simulate clinical conditions and further elucidate the radiobiological effects of advanced RT techniques.
This paper proposes a novel curve-based or edge-based image registration technique that utilizes the curve transformation function and Gaussian function. It enables deformable image registration between images in different spaces, e.g., different color spaces or different medical image modalities. In particular, piecewise polynomial fitting is used to fit a curve and convert it to the global cubic B-spline control points. The transformation between the curves in the reference and source images are performed by using these control points. The image area is segmented with respect to the reference curve for the moving pixels. The Gaussian function, which is symmetric about the coordinates of the points of the reference curve, was used to improve the continuity in the intra- and inter-segmented areas. The overall result on curve transformation by means of the Hausdroff distance was 5.820 ± 1.127 pixels on average on several 512 × 512 synthetic images. The proposed method was compared with an ImageJ plugin, namely bUnwarpJ, and a software suite for deformable image registration and adaptive radiotherapy research, namely DIRART, to evaluate the image registration performance. The experimental result shows that the proposed method yielded better image registration performance than its counterparts. On average, the proposed method could reduce the root mean square error from 2970.66 before registration to 1677.94 after registration and can increase the normalized cross-correlation coefficient from 91.87% before registration to 97.40% after registration.
17 April 2026 in Technology in Cancer Research & Treatment
Introduction: Spatially Fractionated Radiotherapy (SFRT) delivers intentionally heterogeneous dose distributions with alternating high- and low-dose regions and has been widely applied in the management of bulky tumors. In SFRT, high-dose sub-volumes (referred to as vertices) are distributed within the gross tumor volume (GTV) to create a spatial peak–valley dose pattern. However, studies of SFRT using the TomoTherapy platform remain limited. This study evaluates the dosimetric performance of GRID and lattice vertex designs using TomoHelical and TomoDirect techniques. Methods: A phantom-based planning study was performed with two simulated GTV representing medium- and large-sized tumors. Cylindrical GRID vertices and spherical lattice vertices were created with diameters of 1.00 cm and 1.25 cm and corresponding center-to-center spacings of 3.0 cm and 2.5 cm, respectively. Treatment plans were created using TomoHelical and TomoDirect techniques with identical prescription criteria, requiring at least 50% of the target volume to receive 15 Gy in a single fraction. Beam-on time, normal tissue dose metrics (V30% and V50%), homogeneity index, conformity index, peak-to-edge dose ratio (PEDR), and peak-to-valley dose ratio (PVDR) were evaluated. Delivery accuracy was assessed using ArcCHECK measurements with a 3%/2 mm gamma criterion. Results: All plans met prescription and delivery accuracy requirements, with gamma passing rates exceeding 95%. TomoHelical produced higher PVDR and PEDR values, improved conformity, and lower V50% compared with TomoDirect. TomoDirect achieved shorter beam-on times but showed greater variability in vertex mean dose. Lattice configurations yielded higher PVDR values than GRID, while vertex diameter had minimal impact on most dosimetric parameters. Conclusion: TomoHelical delivery combined with lattice designs provided superior dose modulation and normal tissue sparing for SFRT, while requiring longer delivery times. In contrast, GRID designs enabled faster treatment delivery. These findings provide practical guidance for optimizing SFRT planning using the TomoTherapy platform.