Christian Affolter

Mr. Christian Affolter

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2011 in Journal of Composites for Construction
Verified
Journal Article
Closed access
TPTerrasi Giovanni Pietro
Terrasi Giovanni Pietro
CAChristian Affolter
Christian Affolter
MBMichel Barbezat
Michel Barbezat
Efficient use of pultruded carbon fiber–reinforced plastic profiles (CFRP tendons) to prestress high-performance concrete (HPC) highly depends on the performance of the anchorage system and on material choice. For current applications, a prestressing degree of approximately 40% of the CFRP material strength is utilized in pretensioned concrete elements. A higher prestress implicates lower costs of fully prestressed concrete elements. The present project aimed to optimize the design of a removable and reusable pretensioning anchorage system for sand-coated CFRP rods. The optimized design was achieved by means of finite-element calculations in which parametric studies were complemented with extensive experimental work for validation. Analytical results demonstrated a reduction up to 25% for the relevant stress peaks in the tendons. The static rupture load under laboratory conditions increased by 25%, and the pretensioning level on-site could be increased by 50%. This improvement in production efficiency can...

1 May 2008 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
BWBernhard Weisse
Bernhard Weisse
CAChristian Affolter
Christian Affolter
ASA Stutz
A Stutz
TPTerrasi Giovanni Pietro
Terrasi Giovanni Pietro
SKS Köbel
S Köbel
WWW Weber
W Weber
The probability of in-vivo failure of ceramic hip joint implants is very low (0.05–0.004 per cent). Besides material flaws and overloading, improper handling during implantation may induce fractures of the ceramic ball head in the long term. This study focuses on the influence of contaminants located in the stem—ball interface and on the use of damaged metal tapers on the strength of ceramic ball heads. Mechanical tests on alumina ball heads according to the standard ISO 7206-10 were performed to identify their effect on the static fracture load. A decrease of up to 90 per cent with respect to the reference static fracture load was found when contaminants such as bone chips, soft tissue, or blood were present. Reductions of 57 per cent and 27 per cent were observed for deformed stem cross-sections (from circular to elliptical) and for flattened stems respectively, making deformed stems another influential parameter. Since any alteration of the interface between the metal taper and the ceramic ball head yields a non-uniform load introduction and hence results in stress concentrations, its presence has to be avoided.

1 August 2012 in Journal of Composites for Construction
Verified
Journal Article
Closed access
TPTerrasi Giovanni Pietro
Terrasi Giovanni Pietro
LBLuke Bisby
Luke Bisby
MBMichel Barbezat
Michel Barbezat
CAChristian Affolter
Christian Affolter
EHErich Hugi
Erich Hugi
More sustainable precast concrete structural elements are emerging from the research community utilizing high-strength, self-consolidating fiber-reinforced concrete (HPSCC) reinforced with noncorroding prestressed carbon-fiber-reinforced polymer (CFRP). An example of this is a new type of precast CFRP pretensioned HPSCC panel intended as load-bearing beams or columns for use in building envelopes. Such elements have recently been applied to architectural façade elements in Europe. A key issue in the implementation of these elements as load-carrying members in buildings is demonstrating satisfactory performance in fire. It is well known that the bond between FRP reinforcing bars and concrete deteriorates at elevated temperatures. It is also known that high-strength concrete is susceptible to explosive spalling when subjected to fire. Reductions in FRP reinforcement tensile and bond strength during fire, effects on the load-bearing capacity of prestressed concrete structures, and the explosive spall...

1 October 2009 in Acta Biomaterialia
Verified
Journal Article
Closed access
CFClaudiu Valentin Falub
Claudiu Valentin Falub
GTGötz Thorwarth
Götz Thorwarth
CAChristian Affolter
Christian Affolter
UMUlrich Müller
Ulrich Müller
CVCyril Voisard
Cyril Voisard
RHRoland Hauert
Roland Hauert

27 August 2024 in Metals
Verified
Journal Article
Open access
PDF file
ZLZongchen LI
Zongchen LI
CAChristian Affolter
Christian Affolter
The inadequate fatigue performance of Laser Powder Bed Fusion (L-PBF) Ti-6Al-4V alloy, primarily due to intrinsic defects, poses a significant challenge for industrial applications. Internal defects often serve as initiation sites for fatigue cracks, significantly impacting the fatigue life of L-PBF Ti-6Al-4V components. Accurate evaluation of the role of internal defects in fatigue performance and quantitative analysis of influential parameters are crucial for guiding optimal L-PBF manufacturing design. This study aims to critically review recent notable contributions focusing on high-cycle fatigue (HCF) in these alloys, with many of the presented insights being easily transferred to other types of AM alloys. Efforts have been made to identify correlations between fatigue life at various stages and critical internal defects. Key aspects, including microstructure and post-processing treatments, and their effects on HCF have been thoroughly analyzed. The findings enhance the scientific understanding of fatigue performance of L-PBF Ti-6Al-4V alloy and open new avenues for future research.

23 July 2014 in Polymers
Verified
Journal Article
Open access
PDF file
TPTerrasi Giovanni Pietro
Terrasi Giovanni Pietro
UMUrs Meier
Urs Meier
CAChristian Affolter
Christian Affolter
This paper discusses the long-term behavior of a series of highly-loaded, spun concrete pole specimens prestressed with carbon fiber-reinforced polymer (CFRP) tendons, which were subjected to outdoor four-point bending creep tests since 1996 in the frame of collaboration with the Swiss precast concrete producer, SACAC (Società Anonima Cementi Armati Centrifugati). The 2 m span cylindrical beams studied are models for lighting poles produced for the last 10 years and sold on the European market. Five thin-walled pole specimens were investigated (diameter: 100 mm; wall-thickness: 25–27 mm). All specimens were produced in a pretensioning and spinning technique and were prestressed by pultruded CFRP tendons. Initially, two reference pole specimens were tested in quasi-static four-point bending to determine the short-term failure moment and to model the short-term flexural behavior. Then, three pole specimens were loaded to different bending creep moments: while the lowest loaded specimen was initially uncracked, the second specimen was loaded with 50% of the short-term bending failure moment and exhibited cracking immediately after load introduction. The highest loaded pole specimen sustained a bending moment of 72% of the short-term bending failure moment for 16.5 years before failing in July 2013, due to the bond failure of the tendons, which led to local crushing of the high-performance spun concrete (HPSC). Besides this, long-term monitoring of the creep tests has shown a limited time- and temperature-dependent increase of the deflections over the years, mainly due to the creep of the concrete. A concrete creep-based model allowed for the calculation of the long-term bending curvatures with reasonable accuracy. Furthermore, the pole specimens showed crack patterns that were stable over time and minimal slippage of the tendons with respect to the pole’s end-faces for the two lower load levels. The latter proves the successful and durable anchorage of these novel CFRP prestressing tendons in thin-walled, precast concrete members under realistic long-term service loads.