Obstructive sleep apnea is associated with considerable health risks. Although continuous positive airway pressure (CPAP) can mitigate these risks, effectiveness can be reduced by inadequate adherence to treatment. We evaluated the clinical safety and effectiveness of upper-airway stimulation at 12 months for the treatment of moderate-to-severe obstructive sleep apnea. Using a multicenter, prospective, single-group, cohort design, we surgically implanted an upper-airway stimulation device in patients with obstructive sleep apnea who had difficulty either accepting or adhering to CPAP therapy. The primary outcome measures were the apnea–hypopnea index (AHI; the number of apnea or hypopnea events per hour, with a score of ≥15 indicating moderate-to-severe apnea) and the oxygen desaturation index (ODI; the number of times per hour of sleep that the blood oxygen level drops by ≥4 percentage points from baseline). Secondary outcome measures were the Epworth Sleepiness Scale, the Functional Outcomes of Sleep Questionnaire (FOSQ), and the percentage of sleep time with the oxygen saturation less than 90%. Consecutive participants with a response were included in a randomized, controlled therapy-withdrawal trial. The study included 126 participants; 83% were men. The mean age was 54.5 years, and the mean body-mass index (the weight in kilograms divided by the square of the height in meters) was 28.4. The median AHI score at 12 months decreased 68%, from 29.3 events per hour to 9.0 events per hour (P<0.001); the ODI score decreased 70%, from 25.4 events per hour to 7.4 events per hour (P<0.001). Secondary outcome measures showed a reduction in the effects of sleep apnea and improved quality of life. In the randomized phase, the mean AHI score did not differ significantly from the 12-month score in the nonrandomized phase among the 23 participants in the therapy-maintenance group (8.9 and 7.2 events per hour, respectively); the AHI score was significantly higher (indicating more severe apnea) among the 23 participants in the therapy-withdrawal group (25.8 vs. 7.6 events per hour, P<0.001). The ODI results followed a similar pattern. The rate of procedure-related serious adverse events was less than 2%. In this uncontrolled cohort study, upper-airway stimulation led to significant improvements in objective and subjective measurements of the severity of obstructive sleep apnea. (Funded by Inspire Medical Systems; STAR ClinicalTrials.gov number, NCT01161420.)
15 February 2014 in Journal of Clinical Sleep Medicine
Oral appliances (OA) have emerged as an alternative to continuous positive airway pressure (CPAP) for obstructive sleep apnea (OSA) treatment. The most commonly used OA reduces upper airway collapse by advancing the mandible (OAm). There is a strong evidence base demonstrating OAm improve OSA in the majority of patients, including some with more severe disease. However OAm are not efficacious for all, with approximately one-third of patients experiencing no therapeutic benefit. OAm are generally well tolerated, although short-term adverse effects during acclimatization are common. Long-term dental changes do occur, but these are for the most part subclinical and do not preclude continued use. Patients often prefer OAm to gold-standard CPAP treatment. Head-to-head trials confirm CPAP is superior in reducing OSA parameters on polysomnography; however, this greater efficacy does not necessarily translate into better health outcomes in clinical practice. Comparable effectiveness of OAm and CPAP has been attributed to higher reported nightly use of OAm, suggesting that inferiority in reducing apneic events may be counteracted by greater treatment adherence. Recently, significant advances in commercially available OAm technologies have been made. Remotely controlled mandibular positioners have the potential to identify treatment responders and the level of therapeutic advancement required in single night titration polysomnography. Objective monitoring of OAm adherence using small embedded temperature sensing data loggers is now available and will enhance clinical practice and research. These technologies will further enhance efficacy and effectiveness of OAm treatment for OSA.
30 March 2023 in International Forum of Allergy & Rhinology
To study the possible predictive value of drug-induced sleep endoscopy (DISE) in assessing therapeutic response to implanted upper airway stimulation (UAS) for obstructive sleep apnea (OSA). During DISE, artificial sleep is induced by midazolam and/or propofol, and the pharyngeal collapse patterns are visualized using a flexible fiberoptic nasopharyngoscope. The level (palate, oropharynx, tongue base, hypopharynx/epiglottis), the direction (anteroposterior, concentric, lateral), and the degree of collapse (none, partial, or complete) were scored in a standard fashion. We report on the correlation between DISE results and therapy response in 21 OSA patients (apnea-hypopnea index [AHI] 38.5 ± 11.8/h; body mass index [BMI] 28 ± 2 kg/m(2), age 55 ± 11 y, 20 male/1 female) who underwent DISE before implantation of a UAS system. Statistical analysis revealed a significantly better outcome with UAS in patients (n = 16) without palatal complete concentric collapse (CCC), reducing AHI from 37.6 ± 11.4/h at baseline to 11.1 ± 12.0/h with UAS (p < 0.001). No statistical difference was noted in AHI or BMI at baseline between the patients with and without palatal CCC. In addition, no predictive value was found for the other DISE collapse patterns documented. The absence of palatal CCC during DISE may predict therapeutic success with implanted UAS therapy. DISE can be recommended as a patient selection tool for implanted UAS to treat OSA.