Background: The International Classification of Functioning, Disability, and Health (ICF) Core Sets for children and youth with cerebral palsy (CP) offer service providers and stakeholders a specific framework to explore functioning and disability for assessment, treatment, evaluation, and policy purposes in a global context. Objective: Describe global initiatives applying the ICF Core Sets for children and youth with CP, with a focus on contributions to clinical practice and challenges in their implementation. Methods: This is a descriptive cross-sectional study. Ongoing initiatives applying the ICF Core Sets for CP in Russia, Poland, Malawi, and Brazil are included. Results: The main contributions of applying the ICF Core Sets for children and youth with CP include: (1) an objective description of abilities and limitations in everyday activities; (2) a consistent identification of facilitators and barriers influencing functioning; (3) a practical communication tool promoting client-centered care and multidisciplinary teamwork; and, (4) a useful guideline for measurement selection. The main challenges of adopting the ICF Core Sets are related to lack of ICF knowledge requiring intense training and translating results from standardized measures into the ICF qualifiers in a consistent way. Conclusions: Global initiatives include research and clinical applications at the program, service and system levels. The ICF Core Sets for CP are useful tools to guide service provision and build profiles of functioning and disability. Global interprofessional collaboration, capacity training, and informatics (e-records) will maximize their applications and accelerate adoption.
Poly(lactic-co-glycolic acid) (PLGA) nerve tube guides, made of a novel proportion (90:10) of the two polymers, poly(l-lactide): poly(glycolide) and covered with a neural cell line differentiated in vitro, were tested in vivo for promoting nerve regeneration across a 10-mm gap of the rat sciatic nerve. Before in vivo testing, the PLGA 90:10 tubes were tested in vitro for water uptake and mass loss and compared with collagen sheets. The water uptake of the PLGA tubes was lower, and the mass loss was more rapid and higher than those of the collagen sheets when immersed in phosphate-buffered saline (PBS) solution. The pH values of immersing PBS did not change after soaking the collagen sheets and showed to be around 7.4. On the other hand, the pH values of PBS after soaking PLGA tubes decreased gradually during 10 days reaching values around 3.5. For the in vivo testing, 22 Sasco Sprague adult rats were divided into four groups—group 1: gap not reconstructed; group 2: gap reconstructed using an autologous nerve graft; group 3: gap reconstructed with PLGA 90:10 tube guides; group 4: gap reconstructed with PLGA 90:10 tube guides covered with neural cells differentiated in vitro. Motor and sensory functional recovery was evaluated throughout a healing period of 20 weeks using sciatic functional index, static sciatic index, extensor postural thrust, withdrawal reflex latency, and ankle kinematics. Stereological analysis was carried out on regenerated nerve fibers. Both motor and sensory functions improved significantly in the three experimental nerve repair groups, although the rate and extent of recovery was significantly higher in the group where the gap was reconstructed using the autologous graft. The presence of neural cells covering the inside of the PLGA tube guides did not make any difference in the functional recovery. By contrast, morphometric analysis showed that the introduction of N1E-115 cells inside PLGA 90:10 tube guides led to a significant lower number and size of regenerated nerve fibers, suggesting thus that this approach is not adequate for promoting peripheral nerve repair. Further studies are warranted to assess the role of other cellular systems as a foreseeable therapeutic strategy in peripheral nerve regeneration.
11 February 2010 in Journal of NeuroEngineering and Rehabilitation
Peripheral nerves possess the capacity of self-regeneration after traumatic injury but the extent of regeneration is often poor and may benefit from exogenous factors that enhance growth. The use of cellular systems is a rational approach for delivering neurotrophic factors at the nerve lesion site, and in the present study we investigated the effects of enwrapping the site of end-to-end rat sciatic nerve repair with an equine type III collagen membrane enriched or not with N1E-115 pre-differentiated neural cells. After neurotmesis, the sciatic nerve was repaired by end-to-end suture (End-to-Endgroup), end-to-end suture enwrapped with an equine collagen type III membrane (End-to-EndMembgroup); and end-to-end suture enwrapped with an equine collagen type III membrane previously covered with neural cells pre-differentiatedin vitrofrom N1E-115 cells (End-to-EndMembCellgroup). Along the postoperative, motor and sensory functional recovery was evaluated using extensor postural thrust (EPT), withdrawal reflex latency (WRL) and ankle kinematics. After 20 weeks animals were sacrificed and the repaired sciatic nerves were processed for histological and stereological analysis. Results showed that enwrapment of the rapair site with a collagen membrane, with or without neural cell enrichment, did not lead to any significant improvement in most of functional and stereological predictors of nerve regeneration that we have assessed, with the exception of EPT which recovered significantly better after neural cell enriched membrane employment. It can thus be concluded that this particular type of nerve tissue engineering approach has very limited effects on nerve regeneration after sciatic end-to-end nerve reconstruction in the rat.