Introduction. Cone-beam computed tomography (CBCT) is considered to be the most informative radiographic method for pre- and postoperative analysis of the maxillary anatomy and for avoiding further complication. Canalis sinuosus is one of such structures that damage can go along with bleeding and neurological symptomatology. The aim of the study was to investigate radiological and morphometric features of the canalis sinuosus in Russian population using CBCT technique. Materials and Methods. 150 CBCT scans of 61 males and 89 females aged from 24 to 80 years were retrospectively studied with different slice thickness and evaluated with regards to prevalence and diameter among age and gender groups in Russia. Results. CS prevalence in this study was 67%, and CS was most frequently presented in the lateral incisor region (33.5%). Women showed statistically higher CS prevalence () than the male group, and there was no statistically significant difference observed between occurrence and localization of CS and age groups. Conclusion. CBCT examination demonstrated good diagnostic efficiency in CS visualization, and the CS may have variations on its location and prevalence with statistically significant differences between the gender group and without significant differences among age groups and can depend on the population.
Dental implant failure in the anterior maxilla can be caused by the range of the features. One of them is neighboring neurovascular structure damage, such as the canalis sinuosus (CS), that carries the superior anterior alveolar nerve. The aim of the report is to demonstrate clinical symptomatology and radiographic signs of CS damage in a 45‐year‐old female patient who underwent upper left lateral incisor extraction and immediate implant placement and implant removal in 16 days secondary to pain and paresthesia in the maxillary left region.
Objectives: To compare 3D cephalometric analysis performed using AI with that conducted manually by a specialist orthodontist. Methods: The CBCT scans (a field of view of 15 × 15 cm) used in the study were obtained from 30 consecutive patients, aged 18 to 50. The 3D cephalometric analysis was conducted using two methods. The first method involved manual tracing performed with the Invivo 6 software (Anatomage Inc., Santa Clara, CA, USA). The second method involved using AI for cephalometric measurements as part of an orthodontic report generated by the Diagnocat system (Diagnocat Ltd., San Francisco, CA, USA). Results: A statistically significant difference within one standard deviation of the parameter was found in the following measurements: SNA, SNB, and the left interincisal angle. Statistically significant differences within two standard deviations were noted in the following measurements: the right and left gonial angles, the left upper incisor, and the right lower incisor. No statistically significant differences were observed beyond two standard deviations. Conclusions: AI in the form of Diagnocat proved to be effective in assessing the mandibular growth direction, defining the skeletal class, and estimating the overbite, overjet, and Wits parameter.
Aim. The aim of the study is to evaluate the difference in MB2 prevalence with different slice thicknesses in maxillary first molars.Materials and Methods. Two hundred nonfilled MB2 canals in maxillary first molars of 156 people (75 females and 81 males) aged from 20 to 73 years old were evaluated with CBCT with different slice thicknesses: 0.5 mm, 1 mm, 3 mm, and 10 mm. A general analysis was performed out, as well as in the age groups and on gender groups.Results. Visualization with 0.5 mm and 1 mm slice thicknesses was 100% and generally equal, in both the male and the female group. General MB2 visualization with 3 mm slice thickness was 42% and 29% for the male group and 27% for the female group. No canals were visualized with 10 mm slice thickness. The study did not demonstrate a statistical difference in the MB2 prevalence between gender and age groups with the 3 mm slice thickness.Conclusion. The most valuable way to evaluate the root canal system in first maxillary molars with CBCT is using 1 mm slice thickness for both genders and every age group.
1 January 2019 in Indian Journal of Dental Research
Introduction: One of the key stages of evaluating an edentulous ridge prior to dental implant placement is the analysis of neighboring anatomical structures such as canalis sinuosus (CS) with cone-beam computed tomography (CBCT). CBCT visualization has its own features, such as the change of slice thickness. The aim of the study was to analyze CS prevalence in relation to the slice thickness and CS diameter according to CBCT scans. Materials and Methods: In total, 100 CBCT scans of 39 males and 61 females in the age span of 46 to 81 years were retrospectively studied. Terminal alveolar part of CS was analyzed in Ez3D2009 (Vatech) software on panoramic and cross-sectional views with 0.5 mm, 1 mm, 3 mm, and 10 mm slice thicknesses. The prevalence was documented with regard to the diameter and slice thickness and was statistically compared in age and gender groups. Results: This CBCT study demonstrated 55.5% CS prevalence. There was no statistically significant difference in presence between age and gender groups regarding diameter as well as within different slice thickness. The study also showed the importance of the slice thickness choice for CS visualization: the best visualization was reached with 0.5 mm and 1 mm slice thicknesses. Visualization with 0.5 mm and 1 mm slice thicknesses was absolutely the same (55.5%). General CS prevalence with a 10 mm slice thickness (16.5%) was significantly lower (P < 0.05) than the prevalence with a 3 mm slice thickness (20.5%). The correlation between the slice thickness and a diameter more than 1.5 mm in size was not found. Conclusion: CBCT analysis showed that the highest CS prevalence was detected with the use of 0.5/1 mm slice thickness. As well, the higher CS diameter, the better is its visualization.