Alexander Moskalensky

Dr. Alexander Moskalensky

Novosibirsk State University
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2019 in Computational and Structural Biotechnology Journal
Verified
Journal Article
Open access
AVAleksey Yu. Vorobev
Aleksey Yu. Vorobev
AMAlexander Moskalensky
Alexander Moskalensky
Photoremovable protective groups (PPGs) and related "caged" compounds have been recognized as a powerful tool in an arsenal of life science methods. The present review is focused on recent advances in design of "caged" compounds which function in red or near-infrared region. The naive comparison of photon energy with that of organic bond leads to the illusion that long-wavelength activation is possible only for weak chemical bonds like N-N. However, there are different means to overcome this threshold and shift the uncaging functionality into red or near-infrared regions for general organic bonds. We overview these strategies, including the novel photochemical and photophysical mechanisms used in newly developed PPGs, singlet-oxygen-mediated photolysis, and two-photon absorption. Recent advances in science places the infrared-sensitive PPGs to the same usability level as traditional ones, facilitating in vivo application of caged compounds.

1 January 2012 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
AKAnastasiya I. Konokhova
Anastasiya I. Konokhova
MYMaxim Yurkin
Maxim Yurkin
AMAlexander Moskalensky
Alexander Moskalensky
ACAndrei V. Chernyshev
Andrei V. Chernyshev
GTGalina A. Tsvetovskaya
Galina A. Tsvetovskaya
VMValeri P. Maltsev
Valeri P. Maltsev
We describe a novel approach to study blood microparticles using the scanning flow cytometer, which measures light scattering patterns (LSPs) of individual particles. Starting from platelet-rich plasma, we separated spherical microparticles from non-spherical plasma constituents, such as platelets and cell debris, based on similarity of their LSP to that of sphere. This provides a label-free method for identification (detection) of microparticles, including those larger than 1 µm. Next, we rigorously characterized each measured particle, determining its size and refractive index including errors of these estimates. Finally, we employed a deconvolution algorithm to determine size and refractive index distributions of the whole population of microparticles, accounting for largely different reliability of individual measurements. Developed methods were tested on a blood sample of a healthy donor, resulting in good agreement with literature data. The only limitation of this approach is size detection limit, which is currently about 0.5 µm due to used laser wavelength of 0.66 µm.

1 January 2013 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
AMAlexander Moskalensky
Alexander Moskalensky
MYMaxim Yurkin
Maxim Yurkin
AKAnastasiya I. Konokhova
Anastasiya I. Konokhova
DSDmitry I. Strokotov
Dmitry I. Strokotov
VNVyacheslav M. Nekrasov
Vyacheslav M. Nekrasov
VMValeri P. Maltsev
Valeri P. Maltsev
We introduce a novel approach for determination of volume and shape of individual blood platelets modeled as an oblate spheroid from angle-resolved light scattering with flow-cytometric technique. The light-scattering profiles (LSPs) of individual platelets were measured with the scanning flow cytometer and the platelet characteristics were determined from the solution of the inverse light-scattering problem using the precomputed database of theoretical LSPs. We revealed a phenomenon of parameter compensation, which is partly explained in the framework of anomalous diffraction approximation. To overcome this problem, additional a priori information on the platelet refractive index was used. It allowed us to determine the size of each platelet with subdiffraction precision and independent of the particular value of the platelet aspect ratio. The shape (spheroidal aspect ratio) distributions of platelets showed substantial differences between native and activated by 10 μM adenosine diphosphate samples. We expect that the new approach may find use in hematological analyzers for accurate measurement of platelet volume distribution and for determination of the platelet activation efficiency.

4 May 2011 in Cytometry Part A
Verified
Journal Article
Open access
PDF file
DSDmitry I. Strokotov
Dmitry I. Strokotov
AMAlexander Moskalensky
Alexander Moskalensky
VNVyacheslav M. Nekrasov
Vyacheslav M. Nekrasov
VMValeri P. Maltsev
Valeri P. Maltsev
We instrumentally, theoretically, and experimentally demonstrate a new approach for characterization of nonspherical individual particles from light scattering. Unlike the original optical scheme of the scanning flow cytometer that measures an angle-resolved scattering corresponding in general to S11 element of the light-scattering matrix, the modernized instrument allows us to measure the polarized light-scattering profile of individual particles simultaneously. Theoretically, the polarized profile is expressed by the combination of a few light-scattering matrix elements. This approach supports us with additional independent data to characterize a particle with a complex shape and an internal structure. Applicability of the new method was demonstrated from analysis of polymer bispheres. The bisphere characteristics, sizes, and refractive indices of each sphere composing the bisphere were successfully retrieved from the solution of the inverse light-scattering problem. The solution provides determination of the Eulerian angles, which describe the orientation of the bispheres relative to the direction of the incident laser beam and detecting polarizer of the optical system. Both the ordinary and polarized profiles show a perfect agreement with T-matrix simulation resulting to 50-nm precision for sizing of bispheres. © 2011 International Society for Advancement of Cytometry.

25 September 2018 in Platelets
Verified
Journal Article
Closed access
AMAlexander Moskalensky
Alexander Moskalensky
ALAlena L. Litvinenko
Alena L. Litvinenko
The well-known platelet shape change is the universal hallmark of activation. This review uncovers the biophysics underlying this rapid and dramatic transformation. We aim to give a broad vision of the interplay between different cytoskeletal subsystems, which is based on physical considerations and recent advances in mathematics and computational biology. These novel findings lead to the understanding that the ring of microtubules counterbalances cortical tension in the resting platelet, making it a “mechanically charged” system. Platelet activation breaks the balance via several mechanisms, triggering rapid ring buckling and cell rounding. Based on the review of known data concerning the relations between platelet shape and function, we hypothesize that disk-to-sphere transformation facilitates platelet adhesion under flow. Conclusions of the paper may be useful for the development of novel, cytoskeletal-based strategies of antiplatelet therapy.

21 March 2015 in Cytometry Part A
Verified
Journal Article
Open access
PDF file
AKAnastasiya I. Konokhova
Anastasiya I. Konokhova
DCDarya N. Chernova
Darya N. Chernova
AMAlexander Moskalensky
Alexander Moskalensky
DSDmitry I. Strokotov
Dmitry I. Strokotov
MYMaxim Yurkin
Maxim Yurkin
VMValeri P. Maltsev
Valeri P. Maltsev
Importance of microparticles (MPs), also regarded as extracellular vesicles, in many physiological processes and clinical conditions motivates one to use the most informative and precise methods for their characterization. Methods based on individual particle analysis provide statistically reliable distributions of MP population over characteristics. Although flow cytometry is one of the most powerful technologies of this type, the standard forward‐versus‐side‐scattering plots of MPs and platelets (PLTs) overlap considerably because of similarity of their morphological characteristics. Moreover, ordinary flow cytometry is not capable of measurement of size and refractive index (RI) of MPs. In this study, we 1) employed the potential of the scanning flow cytometer (SFC) for identification and characterization of MPs from light scattering; 2) suggested the reference method to characterize MP morphology (size and RI) with high precision; and 3) determined the lowest size of a MP that can be characterized from light scattering with the SFC. We equipped the SFC with 405 and 488 nm lasers to measure the light‐scattering profiles and side scattering from MPs, respectively. The developed two‐stage method allowed accurate separation of PLTs and MPs in platelet‐rich plasma. We used two optical models for MPs, a sphere and a bisphere, in the solution of the inverse light‐scattering problem. This solution provides unprecedented precision in determination of size and RI of individual spherical MPs—median uncertainties (standard deviations) were 6 nm and 0.003, respectively. The developed method provides instrument‐independent quantitative information on MPs, which can be used in studies of various factors affecting MP population. © 2015 International Society for Advancement of Cytometry