Energy storage systems are an effective solution to manage the intermittency of renewable energies, balance supply, and demand. Numerous studies recommend adopting a shared energy storage system (ESS) as opposed to multiple single ESSs because of their high prices and inefficiency. Thus, this study examines a shared storage system in a grid-connected microgrid. By modifying the power outputs of the energy resources, this work intends to implement an economic dispatch of a shared ESS in order to satisfy the power balance and lower the overall cost of electricity. In this context, an optimization problem was formulated and developed using a mixed-integer linear programming (MILP) model. Furthermore, a pilot project (the Solar Decathlon Africa Village) in the Green & Smart Building Park (GSBP), Benguerir, Morocco, was employed to evaluate and verify the proposed approach. Some comparable scenarios were therefore run in a MATLAB environment. The collected findings demonstrate the efficacy of the developed algorithm in terms of optimizing energy cost reductions and enhancing the integration of renewable resources into the Moroccan energy mix.
With the use of batteries increases, the complexity of battery management systems (BMSs) also rises. Thus, assessing the functionality of BMSs and performance of the BMS hardware is of utmost importance. Testing with embedded boards at an early stage of BMS development is a pragmatic approach for developing a BMS because it is cost- and time-efficient and considers hardware performance. In this study, we tested and analyzed the real-time state-of-charge (SOC) estimation using a test platform with limited CPU performance as well as memory resources of the embedded board. We collected battery data on a single-cell basis using a first-order RC equivalent circuit and achieved an accuracy of 95% compared to the measured data obtained using actual battery tests. The SOC estimation method applies the extended Kalman filter (EKF) and unscented Kalman filter (UKF). The experiment was performed on the real-time test platform, with 1%, 2%, and 5% noise in the measurement data. The algorithm complexity and hardware implementation were evaluated in terms of the resources used and processing speed. Although the EKF is cost-effective, its error rate increases by 5% with noise interference. The UKF exhibits high accuracy and noise robustness; however, it has a high resource occupancy.
This paper proposes a coordinated control scheme for wind turbine generators (WTGs) and energy storage in microgrids with high wind power penetration. The proposed scheme aimed to reduce the system frequency deviation caused by variations in wind power and loads. To stabilize the frequency, the WTG and energy storage system (ESS) are used for kinetic energy generation and electrical energy storage, respectively. When the WTG contributes excessively to frequency stabilization in the microgrid with a high wind power penetration, the system frequency may fluctuate considerably. Thus, it is necessary to adjust the contribution of a WTG and to share it with other sources. To achieve our objective, we proposed a coordinated control scheme between the WTG and ESS that shares their releasable and absorbable energies. The coordinated control consistently calculated the releasable and absorbable energies of the WTG and ESS and determined weight factors related to the energy ratios. Accordingly, the weight factors improved the ability of providing supporting frequency stabilization of the WTG and ESS by increasing the stored energy utilization. The performance of the scheme was investigated using MATLAB Simulink Electrical. The results show that the proposed coordinated control successfully stabilized the system frequency by calculating the appropriate contributions required from the WTG and ESS.
7 February 2024 in Journal of Electrical Engineering & Technology
The adoption of distributed energy resources (DERs), such as photovoltaic and energy storage systems, is rapidly increasing in response to global warming. However, their operational complexity and exposure to harsh environmental conditions increase the risk of DC series arc-faults, posing critical challenges to system reliability and safety. This paper presents a novel deep learning approach—the domain fusion-based temporally adaptive arc-fault classification network (DF-TACarcNet)—for detecting DC series arc-fault in DERs. DF-TACarcNet employs dual-channel preprocessing to separately normalize time- and frequency-domain signals while preserving domain-specific characteristics. A temporal convolutional network hierarchically extracts features from each domain, which are then concatenated and processed by a transformer encoder to capture long-range temporal dependencies and inter-domain relationships. Experimental results demonstrate that DF-TACarcNet achieves high arc-fault detection classification accuracy (96.62%) across diverse DERs. Furthermore, model compression enables real-time inference on embedded devices, delivering arc-fault classification reliability with an average inference time of 38.5 ms.