Heart is an important organ of human beings. As more and more heart diseases are caused by people’s living pressure or habits, the diagnosis and treatment of heart diseases also require technical improvement. In order to assist the heart diseases diagnosis, the heart sound signal is used to carry a large amount of cardiac state information, so that the heart sound signal processing can achieve the purpose of heart diseases diagnosis and treatment. In order to quickly and accurately judge the heart sound signal, the classification method based on Wavelet Fractal and twin support vector machine (TWSVM) is proposed in this paper. Firstly, the original heart sound signal is decomposed by wavelet transform, and the wavelet decomposition coefficients of the signal are extracted. Then the two-norm eigenvectors of the heart sound signal are obtained by solving the two-norm values of the decomposition coefficients. In order to express the feature information more abundantly, the energy entropy of the decomposed wavelet coefficients is calculated, and then the energy entropy characteristics of the signal are obtained. In addition, based on the fractal dimension, the complexity of the signal is quantitatively described. The box dimension of the heart sound signal is solved by the binary box dimension method. So its fractal dimension characteristics can be obtained. The above eigenvectors are synthesized as the eigenvectors of the heart sound signal. Finally, the twin support vector machine (TWSVM) is applied to classify the heart sound signals. The proposed algorithm is verified on the PhysioNet/CinC Challenge 2016 heart sound database. The experimental results show that this proposed algorithm based on twin support vector machine (TWSVM) is superior to the algorithm based on support vector machine (SVM) in classification accuracy and speed. The proposed algorithm achieves the best results with classification accuracy 90.4%, sensitivity 94.6%, specificity 85.5% and F1 Score 95.2%.
Because a cardiac function signal cannot reflect cardiac health in all directions, we propose a classification method using ECG and PCG signals based on BiLSTM-GoogLeNet-DS. The electrocardiogram (ECG) and phonocardiogram (PCG) signals used as research objects were collected synchronously. Firstly, the obtained ECG and PCG signals were filtered, and then the ECG and PCG signals were fused and classified by using a bi-directional long short-term memory network (BiLSTM). After that, the time-frequency processing was performed on the filtered ECG and PCG signals to obtain the time-frequency diagram of each signal; the one-dimensional signal was changed into a two-dimensional image signal, and the size of each image signal was adjusted to input the improved GoogLeNet network for classification. Then we obtained the two-channel classification results. The three-channel classification results, combined with the classification results of the above BiLSTM network, were finally obtained. The classification results of these three channels were used to make a decision via the fusion strategy of the improved D-S theory. Finally, we obtained the classification results. Taking 70% of the signals in the database as training data and 30% as test data, the obtained classification accuracy was 96.13%, the sensitivity was 98.48%, the specificity was 90.8%, and the F1 score was 97.24%. From the experimental results, the method proposed in this paper obtained high classification accuracy, and the classification effect was better than a cardiac function signal, which makes up for the low accuracy of the cardiac function signal for judging cardiac disease.
5 February 2024 in Computers in Biology and Medicine
Background: Cerebral blood flow (CBF) auto-regulation function is essential for evaluating CBF status. This article provides an evaluation method of CBF using bioimpedance. Method: A mathematical model of cerebral vascular compliance is established to analyze the effect of autoregulation ability changes on the impedance of CBF. The synchronization signals of impedance and blood pressure are measured, and the peak phase shift is extracted to evaluate the cerebral blood autoregulation function. Results: The experiment results show that the peak phase shift can express the cerebral autoregulation change process. The frontal and occipital region’s peak phase shift changes are 10.32%–37.6% and 11.18%–36.86%, respectively. Significant: The proposed approach could build the relationship between CBF autoregulation and impedance, and this method is noninvasive, continuous, and easy to execute. This study provides a basis for the health assessment of the CBF system using bioimpedance.
Facial expression recognition (FER) plays a significant part in artificial intelligence and computer vision. However, most of facial expression recognition methods have not obtained satisfactory results based on low‐level features. The existed methods used in facial expression recognition encountered the major issues of linear inseparability, large computational burden, and data redundancy. To obtain satisfactory results, we propose an innovative deep learning (DL) model using the kernel entropy component analysis network (KECANet) and directed acyclic graph support vector machine (DAGSVM). We use the KECANet in the feature extraction stage. In the stage of output, binary hashing and blockwise histograms are adopted. We sent the final output features to the DAGSVM classifier for expression recognition. We test the performance of our proposed method on three databases of CK+, JAFFE, and CMU Multi‐PIE. According to the experiment results, the proposed method can learn high‐level features and provide more recognition information in the stage of training, obtaining a higher recognition rate.
Background: Magnetic induction tomography (MIT) is a tomographic imaging technique, which has potential applications in security, industry, and medicine. Typically, sensors form a closed structure around the object. However, the measurement cannot be achieved using a closed sensor array in the process of severe brain trauma nursing and the neurosurgery operation. Results: The new sector sensor array magnetic induction tomography (SMIT) system is developed to realize real-time monitoring in the treatment of the brain. The functions of the drive coil and the sensor coil are separated in this system. The detection sensitivity of the imaging region boundary is analyzed through simulation. The sensor array locates on the high detection-sensitivity area, and the low sensitivity detection area is reserved for operation and clinical equipment. The sensor array received the energy of the signal accounts for reach 90% of the total energy. The integrity measuring data are obtained using a rotating scan in the system. In the experiment, we analyze the effects that system parameters have on the quality of imaging, for example, the scan step size, the number of sensors, the coverage angle of the sensor array and the scan angle. The experiment result provides a reference for the SMIT system design under a particular condition. In the complete measurement, the SMIT system reconstructs the images of center goal and margin goal, and the actual images have high peak signal-to-noise ratio. Conclusions: The SMIT system can rebuild the conductivity distribution of the imaging region using incomplete space. In rotation measurement, the system provides a working place for clinical care. The flexible design of the system based on the experiment result makes the different treatment for brain injury own matched SMIT equipment.