Inorganic nanoparticles have become the focus of modern materials science due to their potential technological importance, particularly in bionanotechnology, which stems from their unique physical properties including size-dependent optical, magnetic, electronic, and catalytic properties. The present article provides an overview on the currently used individual inorganic nanoparticles for in vitro biomedical domains. These inorganic nanoparticles include iron oxides, gold, silver, silica, quantum dots (QDs) and second harmonic generation (SHG) particles. For each of these interesting nanoparticles, the main issues starting from preparation up to bio-related applications are presented.
We demonstrate the possibility to excite second-harmonic (SH) active Fe(IO3)3 nanocrystals with two distinct laser sources at 800 and 1550 nm, and we show, by a complementary experimental and numerical study, how the wavelength flexibility inherent to non-phase-matched SH nanoparticles can be efficiently exploited to increase imaging penetration depth of markers embedded in biological samples.
Diamond-like carbon (DLC) and silicon carbide (SiC) coatings are attractive because of low friction coefficient, high hardness, chemical inertness and smooth finish, which they provide to biomedical devices. Silicon wafers (Si(waf)) and silicone rubber (Si(rub)) plates were coated using plasma-enhanced chemical vapour deposition (PE-CVD) techniques. This article describes: 1- the characterization of modified surfaces using attenuated total reflection-Fourier transform infrared spectroscopy (ATR/FTIR) and contact angle measurements, 2- the results of three in-vitro haemocompatibility assays. Coated surfaces were compared to uncoated materials and various substrates such as polymethylmethacrylate (PMMA), polyethylene (LDPE), polydimethylsiloxane (PDMS) and medical steel (MS). Thrombin generation, blood platelet adhesion and complement convertase activity tests revealed the following classification, from the most to the least heamocompatible surface: Si(rub)/ DLC-Si(rub)/ DLC-Si(waf)/ LDPE/ PDMS/ SiC-Si(waf)/ Si(waf)/ PMMA/ MS. The DLC coating surfaces delayed the clotting time, tended to inhibit the platelet and complement convertase activation, whereas SiC-coated silicon wafer can be considered as thrombogenic. This study has taken into account three events of the blood activation: coagulation, platelet activation and inflammation. The response to those events is an indicator of the in vitro haemocompatibility of the different surfaces and it allows us to select biomaterials for further in vivo blood contacting investigations.