Myounggyu Noh

Myounggyu Noh

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 January 2000 in Journal of Comparative Neurology
Verified
Journal Article
Closed access
PDF file
MHM.A. Howard
M.A. Howard
IVI.O. Volkov
I.O. Volkov
RMR. Mirsky
R. Mirsky
PGP.C. Garell
P.C. Garell
MNMyounggyu Noh
Myounggyu Noh
JBJ.F. Brugge
J.F. Brugge

1 November 1999 in Journal of Neurophysiology
Verified
Journal Article
Open access
PDF file
MSMitchell Steinschneider
Mitchell Steinschneider
IVIgor O. Volkov
Igor O. Volkov
MNMyounggyu Noh
Myounggyu Noh
PGP. Charles Garell
P. Charles Garell
MHMatthew A. Howard
Matthew A. Howard
Voice onset time (VOT) is an important parameter of speech that denotes the time interval between consonant onset and the onset of low-frequency periodicity generated by rhythmic vocal cord vibration. Voiced stop consonants (/b/, /g/, and /d/) in syllable initial position are characterized by short VOTs, whereas unvoiced stop consonants (/p/, /k/, and t/) contain prolonged VOTs. As the VOT is increased in incremental steps, perception rapidly changes from a voiced stop consonant to an unvoiced consonant at an interval of 20–40 ms. This abrupt change in consonant identification is an example of categorical speech perception and is a central feature of phonetic discrimination. This study tested the hypothesis that VOT is represented within auditory cortex by transient responses time-locked to consonant and voicing onset. Auditory evoked potentials (AEPs) elicited by stop consonant-vowel (CV) syllables were recorded directly from Heschl's gyrus, the planum temporale, and the superior temporal gyrus in three patients undergoing evaluation for surgical remediation of medically intractable epilepsy. Voiced CV syllables elicited a triphasic sequence of field potentials within Heschl's gyrus. AEPs evoked by unvoiced CV syllables contained additional response components time-locked to voicing onset. Syllables with a VOT of 40, 60, or 80 ms evoked components time-locked to consonant release and voicing onset. In contrast, the syllable with a VOT of 20 ms evoked a markedly diminished response to voicing onset and elicited an AEP very similar in morphology to that evoked by the syllable with a 0-ms VOT. Similar response features were observed in the AEPs evoked by click trains. In this case, there was a marked decrease in amplitude of the transient response to the second click in trains with interpulse intervals of 20–25 ms. Speech-evoked AEPs recorded from the posterior superior temporal gyrus lateral to Heschl's gyrus displayed comparable response features, whereas field potentials recorded from three locations in the planum temporale did not contain components time-locked to voicing onset. This study demonstrates that VOT at least partially is represented in primary and specific secondary auditory cortical fields by synchronized activity time-locked to consonant release and voicing onset. Furthermore, AEPs exhibit features that may facilitate categorical perception of stop consonants, and these response patterns appear to be based on temporal processing limitations within auditory cortex. Demonstrations of similar speech-evoked response patterns in animals support a role for these experimental models in clarifying selected features of speech encoding.

1 December 2001 in Journal of Neurophysiology
Verified
Journal Article
Closed access
PDF file
YFYonatan I. Fishman
Yonatan I. Fishman
IVIgor O. Volkov
Igor O. Volkov
MNMyounggyu Noh
Myounggyu Noh
PGP. Charles Garell
P. Charles Garell
HBHans Bakken
Hans Bakken
MSMitchell Steinschneider
Mitchell Steinschneider
Some musical chords sound pleasant, or consonant, while others sound unpleasant, or dissonant. Helmholtz's psychoacoustic theory of consonance and dissonance attributes the perception of dissonance to the sensation of “beats” and “roughness” caused by interactions in the auditory periphery between adjacent partials of complex tones comprising a musical chord. Conversely, consonance is characterized by the relative absence of beats and roughness. Physiological studies in monkeys suggest that roughness may be represented in primary auditory cortex (A1) by oscillatory neuronal ensemble responses phase-locked to the amplitude-modulated temporal envelope of complex sounds. However, it remains unknown whether phase-locked responses also underlie the representation of dissonance in auditory cortex. In the present study, responses evoked by musical chords with varying degrees of consonance and dissonance were recorded in A1 of awake macaques and evaluated using auditory-evoked potential (AEP), multiunit activity (MUA), and current-source density (CSD) techniques. In parallel studies, intracranial AEPs evoked by the same musical chords were recorded directly from the auditory cortex of two human subjects undergoing surgical evaluation for medically intractable epilepsy. Chords were composed of two simultaneous harmonic complex tones. The magnitude of oscillatory phase-locked activity in A1 of the monkey correlates with the perceived dissonance of the musical chords. Responses evoked by dissonant chords, such as minor and major seconds, display oscillations phase-locked to the predicted difference frequencies, whereas responses evoked by consonant chords, such as octaves and perfect fifths, display little or no phase-locked activity. AEPs recorded in Heschl's gyrus display strikingly similar oscillatory patterns to those observed in monkey A1, with dissonant chords eliciting greater phase-locked activity than consonant chords. In contrast to recordings in Heschl's gyrus, AEPs recorded in the planum temporale do not display significant phase-locked activity, suggesting functional differentiation of auditory cortical regions in humans. These findings support the relevance of synchronous phase-locked neural ensemble activity in A1 for the physiological representation of sensory dissonance in humans and highlight the merits of complementary monkey/human studies in the investigation of neural substrates underlying auditory perception.

1 February 1997 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MNMyounggyu Noh
Myounggyu Noh
EME.H. Maslen
E.H. Maslen
A signal processing technique is presented by which the position of a rotor supported in magnetic bearings may be deduced from the bearing current waveform. The bearing currents are presumed to be developed with a two-state switching amplifier which produces a substantial high-frequency switching ripple. This ripple is demodulated using a parameter estimation technique which extracts the length of the bearing air gap while rejecting the influence of amplifier voltage and duty-cycle variation. The performance of the estimator is evaluated both by simulation and experiment. The method is demonstrated to produce a sensor with bandwidth of at least 1 kHz and acceptably low feed-through of the bearing force.

1 October 1996 in Journal of Tribology
Verified
Journal Article
Closed access
PDF file
EME. H. Maslen
E. H. Maslen
PAP. E. Allaire
P. E. Allaire
MNMyounggyu Noh
Myounggyu Noh
CSC. K. Sortore
C. K. Sortore
Magnetic bearings have relatively low power consumption compared to fluid film and rolling element bearings. They are now candidates for supporting gas turbines and aeropropulsion engines. This paper describes the design and construction of permanent magnet biased, actively controlled magnetic bearings for a flexible rotor. The rotor was originally supported in fluid film bearings consuming as much as 3000 watts of power. For the magnetic bearing, both permanent magnets and electromagnets are used in a configuration which effectively provides the necessary fluxes in the appropriate air gaps to support the rotor. The theoretical development related to the bearing design is presented along with some experimental performance results. The results include measurements of power consumption, load capacity, bearing linearized coefficients, and the dynamic response of the rotor. The measured total power consumption, excluding shaft losses, was 210 watts in the permanent magnet biased bearing.

28 June 2010 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HLHak-In Lee
Hak-In Lee
MNMyounggyu Noh
Myounggyu Noh
Toroidally wound brushless dc (BLDC) machines are compact, economical, and can operate across large air gaps. In this paper, we provide analytical design equations for a radial-flux toroidally wound BLDC machine. The validity of the design equations is checked against finite-element analyses (FEAs) and experiments. It is found that the motor constant calculated by the design equations is off only by 5% from the results by the FEAs or experiments. We also provide an optimization metric that corresponds to the maximization of machine torque while maintaining minimum power loss. Two optimal design cases are presented.