Brandon Boor

Prof. Brandon Boor

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2021 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
TWTianren Wu
Tianren Wu
BBBrandon Boor
Brandon Boor
Urban aerosol measurements are necessary to establish associations between air pollution and human health outcomes and to evaluate the efficacy of air quality legislation and emissions standards. The measurement of urban aerosol particle size distributions (PSDs) is of particular importance as they enable characterization of size-dependent processes that govern a particle's transport, transformation, and fate in the urban atmosphere. PSDs also improve our ability to link air pollution to health effects through evaluation of particle deposition in the respiratory system and inhalation toxicity. To inform future measurements of urban aerosol observations, this paper reviews and critically analyzes the current state of knowledge on urban aerosol PSD measurements by synthesizing 737 PSD observations made between 1998 to 2017 in 114 cities in 43 countries around the globe. Significant variations in the shape and magnitude of urban aerosol number and mass PSDs were identified among different geographical regions. In general, number PSDs in Europe (EU) and North America, Australia, and New Zealand (NAAN) are dominated by nucleation- and Aitken-mode particles. PSDs in Central, South, and Southeast Asia (CSSA) and East Asia (EA) are shifted to larger sizes, with a meaningful contribution from the accumulation mode. Urban mass PSDs are typically bimodal, presenting a dominant mode in the accumulation mode and a secondary mode in the coarse mode. Most PSD observations published in the literature are short-term, with only 14 % providing data for longer than 6 months. There is a paucity of PSDs measured in Africa (AF), CSSA, Latin America (LA), and West Asia (WA), demonstrating the need for long-term aerosol measurements across wide size ranges in many cities around the globe. Geographical variations in urban aerosol effective densities were also reviewed. Size-resolved urban aerosol effective density functions from 3 to 10 000 nm were established for different geographical regions and intra-city sampling locations in order to accurately translate number PSDs to mass PSDs, with significant variations observed between near-road and urban background sites. The results of this study demonstrate that global initiatives are urgently needed to develop infrastructure for routine and long-term monitoring of urban aerosol PSDs spanning the nucleation to coarse mode. Doing so will advance our understanding of spatiotemporal trends in urban PSDs throughout the world and provide a foundation to more reliably elucidate the impact of urban aerosols on atmospheric processes, human health, and climate.

1 November 2017 in Building and Environment
Verified
Journal Article
Closed access
BBBrandon Boor
Brandon Boor
MSMichal P. Spilak
Michal P. Spilak
JLJelle Laverge
Jelle Laverge
ANAtila Novoselac
Atila Novoselac
YXYing Xu
Ying Xu

16 April 2013 in Aerosol Science and Technology
Verified
Journal Article
Open access
BBBrandon Boor
Brandon Boor
JSJeffrey A. Siegel
Jeffrey A. Siegel
ANAtila Novoselac
Atila Novoselac
Particle deposits on indoor surfaces can be as complex and diverse as the indoor environments in which they exist. Dust loading can range over several orders of magnitude, suggesting the existence of different types of particle deposits. These deposits can be broadly classified as either a monolayer, in which particles are sparsely deposited on a surface, or a multilayer, in which particles are deposited on top of one another and there is particle-to-particle adhesion and interaction. Particles within these diverse structures of settled indoor dust can become airborne through a process known as resuspension, which can occur due to airflow in ventilation ducts or human activity indoors. The dust loading and deposit structure on an indoor surface may have important implications for resuspension in the indoor environment. This literature review provides a summary of dust loads found on indoor surfaces in field studies and classifies each dust load as either a monolayer or multilayer particle deposit. The article highlights the unique attributes associated with resuspension from both types of particle deposits by summarizing key findings of the experimental resuspension literature. The fundamental differences in the resuspension process between monolayer and multilayer deposits suggest that resuspension may vary considerably among the broad spectrum of dust loads found on indoor surfaces. Copyright 2013 American Association for Aerosol Research

19 April 2019 in Environmental Science & Technology
Verified
Journal Article
Closed access
Jonathan SladeJonathan Slade
Jonathan Slade
AAAndrew Ault
Andrew Ault
ABAlexander T. Bui
Alexander T. Bui
JDJenna C. Ditto
Jenna C. Ditto
ZLZiying Lei
Ziying Lei
PSPaul B. Shepson
Paul B. Shepson

25 February 2022 in Science Advances
Verified
Journal Article
Open access
CRColleen Marciel F. Rosales
Colleen Marciel F. Rosales
JJJinglin Jiang
Jinglin Jiang
ALAhmad Lahib
Ahmad Lahib
BBBrandon P. Bottorff
Brandon P. Bottorff
EREmily K. Reidy
Emily K. Reidy
PSPhilip S. Stevens
Philip S. Stevens
Surface cleaning using commercial disinfectants, which has recently increased during the coronavirus disease 2019 pandemic, can generate secondary indoor pollutants both in gas and aerosol phases. It can also affect indoor air quality and health, especially for workers repeatedly exposed to disinfectants. Here, we cleaned the floor of a mechanically ventilated office room using a commercial cleaner while concurrently measuring gas-phase precursors, oxidants, radicals, secondary oxidation products, and aerosols in real-time; these were detected within minutes after cleaner application. During cleaning, indoor monoterpene concentrations exceeded outdoor concentrations by two orders of magnitude, increasing the rate of ozonolysis under low (<10 ppb) ozone levels. High number concentrations of freshly nucleated sub–10-nm particles (≥10 5 cm −3 ) resulted in respiratory tract deposited dose rates comparable to or exceeding that of inhalation of vehicle-associated aerosols.

29 November 2017 in Environmental Science & Technology
Verified
Journal Article
Closed access
TWTianren Wu
Tianren Wu
Martin TäubelMartin Täubel
Martin Täubel
RHRauno Holopainen
Rauno Holopainen
AVAnna-Kaisa Viitanen
Anna-Kaisa Viitanen
SVSinikka Vainiotalo
Sinikka Vainiotalo
BBBrandon Boor
Brandon Boor