An understanding of heat transport is relevant to developing efficient strategies for thermal management in areas of study such as microelectronics, as well as for fundamental science purposes. However, the measurement of temperatures in nanostructured environments and in cryogenic conditions remains a challenging task, requiring both high sensitivity and noninvasive approaches. Here, we present a portable nanothermometer based on a molecular two-level quantum system that operates in the (3–20)-K temperature range, with temperatures and spatial resolutions on the order of millikelvins and micrometers, respectively. We validate the performance of this molecular thermometer by estimating the thermal conductivity of a nanopatterned silicon membrane, where we find a quadratic temperature dependence. In addition, we demonstrate two-dimensional temperature mapping via the simultaneous spectroscopy of multiple probes deposited onto such a suspended membrane. Overall, these results demonstrate the unique potential of the proposed molecular thermometer to explore thermal properties with submicron accuracy and unveil related phenomena manifested at cryogenic temperatures.
In the realm of fundamental quantum science and technologies, non‐classical states of light, such as single‐photon Fock states, are widely studied. However, current standards and metrological procedures are not optimized for low light levels. Progress in this crucial scientific domain depends on innovative metrology approaches, utilizing reliable devices based on quantum effects. A new generation of molecule‐based single‐photon sources is presented, combining their integration in a polymeric micro‐lens with pulsed excitation schemes, thereby realizing suitable resources in quantum radiometry. The strategy enhances the efficiency of generated single photon pulses and improves stability, providing a portable source at 784.7 nm that maintains consistent performance even through a cooling and heating cycle. The calibration of a single‐photon avalanche detector is demonstrated using light sources with different photon statistics, and the advantages of the single‐molecule device are discussed. A relative uncertainty on the intrinsic detection efficiency well below 1% is attained, representing a new benchmark in the field.
Two-photon interference underlies the functioning of many quantum photonics devices. It also serves as the prominent tool for testing the indistinguishability of distinct photons. However, as their time-spectral profile becomes more involved, extracting relevant parameters, foremost the central frequency difference, may become difficult. In a parametric approach, these arise from the need for an exhaustive model combined with limited count statistics. Here we discuss a solution to curtail these effects on the evaluation of frequency separation relying on a semiparametric method. The time trace of the quantum interference pattern of two photons from two independent solid-state emitters is preprocessed by means of singular spectral analysis before inspecting its spectral content. This approach allows one to single out the relevant oscillations from both the envelope and the noise, without resorting to fitting. This opens the way for robust and efficient on-line monitoring of quantum emitters.
30 September 2025 in Quantum Science and Technology
We theoretically investigate a single fluorescent molecule as a hybrid quantum optical device, in which multiple external laser sources exert control of the vibronic states. In the high-saturation regime, a coherent interaction is established between the vibrational and electronic degrees of freedom, and molecules can simulate several cavity QED models, whereby a specific vibrational mode plays the role of the cavity mode. Focusing on the specific example where the system is turned into an analogue simulator of the quantum Rabi model, the steady state exhibits vibrational bi-modality resulting in a statistical mixture of highly non-classical vibronic cat states. Applying our paradigm to molecules with prominent spatial asymmetry and combining an optical excitation with a THz(IR) driving, the system can be turned into a single photon transducer. Two possible implementations are discussed based on the coupling to a subwavelength THz patch antenna or a resonant metamaterial. In a nutshell, this work assesses the role of molecules as an optomechanical quantum toolbox for creating hybrid entangled states of electrons, photons, and vibrations, hence enabling frequency conversion over very different energy scales.
In today’s medicine, the celerity of the bio-assays analysis is crucial for the timely selection of the appropriate therapy and hence its effectiveness, especially in case of diseases characterized by the late onset of symptoms. In this paper, a lens-less fiber optics-based fluorescence sensor designed for the measurement of labeled bio-assays is presented and its potential for the early diagnosis of sepsis via C-reactive protein (CRP) detection is demonstrated. The sensor performance results from the combination of two key elements: a planar antenna that redirects fluorescence the marker emission and an automated fiber-based optical system for multi-spot analysis. First, the working principle of the device is demonstrated with a well-established antibody–antigen format (immunoglobulin IgG/anti-IgG assay), reporting more than one order of magnitude enhanced limit of detection (LOD) and limit of quantification (LOQ) for the planar antenna with respect to a standard glass substrate. The prototype is then tested against a sample mimicking a realistic case, prepared with commercially available human serum, showing a LOD and LOQ in the clinical range of interest (0.0015 μg/mL and 0.005 μg/mL, respectively) for the investigation of the sepsis biomarker CRP. These results validate the developed prototype as a simple and easy-to-operate device, compatible with standardized micro-well arrays, and potentially suitable for POC applications.