Che-Chou Shen

Prof. Che-Chou Shen

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in Ultrasonics
Verified
Journal Article
Closed access
CSChe-Chou Shen
Che-Chou Shen
PHPei-Ying Hsieh
Pei-Ying Hsieh

Verified
Journal Article
Open access
PDF file
YLYen-Chung Lin
Yen-Chung Lin
MWMaiszu Wu
Maiszu Wu
YLYuh-Feng Lin
Yuh-Feng Lin
CCChang-Rong Chen
Chang-Rong Chen
CCChang-Yu Chen
Chang-Yu Chen
CPChiung-Chi Peng
Chiung-Chi Peng
Lipid accumulation in renal cells has been implicated in the pathogenesis of obesity-related kidney disease, and lipotoxicity in the kidney can be a surrogate marker for renal failure or renal fibrosis. Fatty acid oxidation provides energy to renal tubular cells. Ca2+ is required for mitochondrial ATP production and to decrease reactive oxygen species (ROS). However, how nifedipine (a calcium channel blocker) affects lipogenesis is unknown. We utilized rat NRK52E cells pre-treated with varying concentrations of nifedipine to examine the activity of lipogenesis enzymes and lipotoxicity. A positive control exposed to oleic acid was used for comparison. Nifedipine was found to activate acetyl Coenzyme A (CoA) synthetase, acetyl CoA carboxylase, long chain fatty acyl CoA elongase, ATP-citrate lyase, and 3-hydroxy-3-methyl-glutaryl-coenzyme A (HMG CoA) reductase, suggesting elevated production of cholesterol and phospholipids. Nifedipine exposure induced a vast accumulation of cytosolic free fatty acids (FFA) and stimulated the production of reactive oxygen species, upregulated CD36 and KIM-1 (kidney injury molecule-1) expression, inhibited p-AMPK activity, and triggered the expression of SREBP-1/2 and lipin-1, underscoring the potential of nifedipine to induce lipotoxicity with renal damage. To our knowledge, this is the first report demonstrating nifedipine-induced lipid accumulation in the kidney.

23 July 2007 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
CSChe-Chou Shen
Che-Chou Shen
YWYu-Chun Wang
Yu-Chun Wang
YHYi-Chun Hsieh
Yi-Chun Hsieh
Generation of tissue harmonic signals during acoustic propagation is based on the combined effect of two different spectral interactions of the transmit signal. One produces harmonic whose frequency is the sum of transmit frequencies. The other results in harmonic at difference frequency of the transmit signals. Both the frequency-sum component and the frequency-difference component are sensitive to the phase of their constitutive spectral signals. In this study, a novel approach for modifying the amplitude of tissue harmonic signal is proposed based on phasing these two components to achieve either harmonic enhancement or suppression. Both experiments and simulations were performed to investigate the effects of 3fo transmit phasing on tissue harmonic generation. Results indicate that the relative phasing between the frequency-sum component and the frequency-difference component markedly changes the amplitude of the second harmonic signal. For harmonic enhancement, approximate 6 dB increase of second harmonic amplitude can be achieved while the lateral harmonic beam pattern also is improved as compared to conventional situations in which only the frequency-sum component is considered. For harmonic suppression, the second harmonic signal also could be significantly reduced by about 11 dB when the frequency-difference component is out of phase with the frequency-sum component. Hence, the method of 3fo transmit phasing has potentials for both improving signal-to-noise ratio in tissue harmonic imaging and enhancing image contrast in contrast-agent imaging by suppression of tissue harmonic background.

23 September 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CSChe-Chou Shen
Che-Chou Shen
PHPei-Ying Hsieh
Pei-Ying Hsieh
Ultrasonic multi-angle plane-wave (PW) coherent compounding relies on delay-and-sum (DAS) beamforming of two-dimensional (2D) echo matrix in both the dimensions PW transmit angle and receiving channel to construct each image pixel. Due to the characteristics of DAS beamforming, PW coherent compounding may suffer from high image clutter when the number of transmit angles is kept low for ultrafast image acquisition. Delay-multiply-and-sum (DMAS) beamforming exploits the spatial coherence of the receiving aperture to suppress clutter interference. Previous attempts to introduce DMAS beamforming into multi-angle PW imaging has been reported but only in either dimension of the 2D echo matrix. In this study, a novel DMAS operation is proposed to extract the 2D spatial coherence of echo matrix for further improvement of image quality. The proposed 2D-DMAS method relies on a flexibly tunable p value to manipulate the signal coherence in the beamforming output. For p = 2.0 as an example, simulation results indicate that 2D-DMAS outperforms other one-dimensional DMAS methods by at least 9.3 dB in terms of ghost-artifact suppression. Experimental results also show that 2D-DMAS provides the highest improvement in lateral resolution by 32% and in image contrast by 15.6 dB relative to conventional 2D-DAS beamforming. Nonetheless, since 2D-DMAS emphasizes signal coherence more than its one-dimensional DMAS counterparts, it suffers from the most elevated speckle variation and the granular pattern in the tissue background.

16 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
CSChe-Chou Shen
Che-Chou Shen
Yen-Chen ChuYen-Chen Chu
Yen-Chen Chu
Conventional ultrasonic coherent plane-wave (PW) compounding corresponds to Delay-and-Sum (DAS) beamforming of low-resolution images from distinct PW transmit angles. Nonetheless, the trade-off between the level of clutter artifacts and the number of PW transmit angle may compromise the image quality in ultrafast acquisition. Delay-Multiply-and-Sum (DMAS) beamforming in the dimension of PW transmit angle is capable of suppressing clutter interference and is readily compatible with the conventional method. In DMAS, a tunable p value is used to modulate the signal coherence estimated from the low-resolution images to produce the final high-resolution output and does not require huge memory allocation to record all the received channel data in multi-angle PW imaging. In this study, DMAS beamforming is used to construct a novel coherence-based power Doppler detection together with the complementary subset transmit (CST) technique to further reduce the noise level. For p = 2.0 as an example, simulation results indicate that the DMAS beamforming alone can improve the Doppler SNR by 8.2 dB compared to DAS counterpart. Another 6-dB increase in Doppler SNR can be further obtained when the CST technique is combined with DMAS beamforming with sufficient ensemble averaging. The CST technique can also be performed with DAS beamforming, though the improvement in Doppler SNR and CNR is relatively minor. Experimental results also agree with the simulations. Nonetheless, since the DMAS beamforming involves multiplicative operation, clutter filtering in the ensemble direction has to be performed on the low-resolution images before DMAS to remove the stationary tissue without coupling from the flow signal.

1 December 2016 in Ultrasonics
Verified
Journal Article
Closed access
CSChe-Chou Shen
Che-Chou Shen
YXYong-Qi Xing
Yong-Qi Xing
GJGency Jeng
Gency Jeng