Michaela Horňáčková

Dr. Michaela Horňáčková


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2014 in The European Physical Journal Applied Physics
Verified
Journal Article
Closed access
PDF file
MHMichaela Horňáčková
Michaela Horňáčková
JPJozef Plavčan
Jozef Plavčan
JRJozef Rakovský
Jozef Rakovský
VPVladimír Porubčan
Vladimír Porubčan
DODaniel Ozdín
Daniel Ozdín
PVPavel Veis
Pavel Veis
Calibration-free laser induced breakdown spectroscopy (CF-LIBS) was used for the determination of elemental composition and quantitative analysis of the Košice meteorite by means of time resolved and broadband emission spectroscopy (200–1000 nm). The electron temperature was determined using the Saha-Boltzmann plot method and the electron density from Stark broadening of the hydrogen H α line (656 nm). Apart from magnesium, silicon and iron, which are the main elemental constituents of examined meteorite fragments, elements such as aluminum, nickel, potassium, sodium, chromium, calcium and manganese were also identified in the obtained LIBS spectra. Concentrations of Al, Ca, Cr, Fe, Mg, Mn, Na, Ni and Si were calculated using the calibration free approach and results were compared with ones obtained from the ICP-MS analyses. For the increase of the CF-LIBS accuracy, a selection of spectral lines was performed. Considering the transition probability, the population of absorbing level, the degree of ionization and predicted elemental concentration we calculated the probability of self-absorption and, consequently, spectral lines with highest self-absorption probability were rejected. CF-LIBS can be used as an alternative method for the meteorite fragments analysis (including the inner part and crust), because this method is quasi non-destructive and therefore analysis of all found fragments with minimal destruction is possible.

18 October 2019 in Atoms
Verified
Journal Article
Open access
PDF file
MHMichaela Horňáčková
Michaela Horňáčková
JPJozef Plavčan
Jozef Plavčan
MHMichal Horňáček
Michal Horňáček
PHPavol HUDEC
Pavol HUDEC
PVPavel Veis
Pavel Veis
In this study, a possibility of laser-induced breakdown spectroscopy (LIBS) for the analysis of zeolites containing copper, chromium, cobalt, cadmium, and lead in the concentration range of 0.05–0.5 wt.% is discussed. For the LIBS analysis, microporous ammonium form of Y zeolite with the silicon to aluminum molar ratio of 2.49 was selected. Zeolites, in the form of pressed pellets, were prepared by volume impregnation from the water solution using Co(CH3COO)2.4H2O, CuSO4.5H20, K2Cr2O7, PbNO3, and CdCl2 to form a sample with different amounts of heavy metals—Co, Cu, Cr, Pb, and Cd. Several spectral lines of the mentioned elements were selected to be fitted to obtain integral line intensity. To prevent the influence of the self-absorption effect, non-resonant spectral lines were selected for the calibration curves construction in most cases. The calibration curves of all elements are observed to be linear with high regression coefficients. On the other hand, the limits of detection (LOD) were calculated according to the 3σ/S formula using the most intensive spectral lines of individual elements, which are 14.4 ppm for copper, 18.5 ppm for cobalt, 16.4 ppm for chromium, 190.7 ppm for cadmium, and 62.6 ppm for lead.