Background: it is undesirable for defects to occur in building partitions and units. There is a need to develop and improve research techniques for locating such defects, especially non-destructive techniques for active thermography. The aim of the experiment was to explore the possibility of using active thermography for testing large-sized building units (with high heat capacity) in order to locate material inclusions. Methods: as part of the experiment, two building partition models—one made of gypsum board (GB) and another made of oriented strand board (OSB)—were built. Three material inclusions (styrofoam, granite, and steel), considerably differing in their thermal parameters, were placed in each of the partitions. A 7.2 kW infrared radiator was used for thermally exciting (heating) the investigated element for 30 min. The distribution of the temperature field was studied on both sides of the partition for a few hours. Results: using the proposed investigative method, one can detect defects in building partitions under at least 22 mm of thick cladding. At a later cooling down phase, inverse temperature contrasts were found to occur—the defects, which at the beginning of cooling down were visible as warmer areas, at a later phase of cooling down are perceived as cooler areas, and vice versa (on the same front surface). In the transmission mode, the defects are always visible as areas warmer than defect-free areas. Moreover, a quantitative (defect location depth) analysis with an accuracy of up to 10% was carried out using the Echo Defect Shape method. Conclusions: active thermography can be used in construction for non-destructive materials testing. When the recording of thermograms is conducted for an appropriate length of time, inverse contrasts can be observed (on the same front surface).
The annual solar gains in public buildings with large percentage of glazing can be shaped by different kinds of shading constructions and by glazing with proper spectral radiative properties. These properties can be obtained by covering panes with special spectral selective coatings or by use of tinted glass. Spectral selective panes enable control of solar gains in summer, reduce heat loss in winter, and reduce electric energy for cooling. These elements, except obvious influence on the annual heat balance of the building, have an impact on thermal and visual comfort parameters. The article presents selected results of the influence of horizontal overhangs and glazing with special spectral radiative properties on the annual thermal balance of analyzed buildings (computer simulations) and on thermal and visual comfort of the users (measurements). The measurements of the microclimate parameters show that it is impossible to maintain thermal comfort conditions during hot summer in natural ventilated buildings with high percentage of glazing without any additional appliances.
Identification of the actual thermal properties of the partitions of building enclosures has a significant meaning in determining the actual energy consumption in buildings and in their thermal comfort parameters. In this context, the total thermal resistance of the exterior walls (and therefore their thermal transmittance) in the building is a major factor which influences its heat losses. There are many methods to determine the total thermal resistance of existing walls, including the quantitative thermography method (also used in this study). This paper presents a comparison of the calculated total thermal resistance values and the measured ones for three kinds of masonry walls without thermal insulation and the same walls insulated with expanded polystyrene boards. The measurements were carried out in quasi-stationary conditions in climate chambers. The following three test methods were used: the temperature-based method (TBM), the heat flow meter method (HFM) and the infrared thermography method (ITM). The measurement results have been found to be in good agreement with the theoretically calculated values: 61% of the measured values were within 10% difference from the mean value of total thermal resistance for a given external wall and 79% of the results were within 20% difference. All of the used measuring methods (TBM, HFM and ITM) have proven to be similarly approximate in obtained total thermal resistances, on average between 6% and 11% difference from the mean values. It has also been noted that, while performing measurements, close attention should be paid to certain aspects, because they can have a major influence on the quality of the result.
1 June 2015 in Civil and Environmental Engineering Reports
The paper pertains to the problem of historic building envelope investigation with the use of active thermography. Mainly emphasized is its application in the detection of different material inclusions in historic walls. Examples of active thermography in the reflective mode application and a description of the experimental investigation has been shown on a wall model with the inclusion of materials with significantly different thermal conductivity and heat capacity, i.e. styrofoam, steel and granite. Thermograms received for every kind of envelope are compared and analyzed. Finally, the summary and conclusion is shown along with the prospects of development and practical application of this kind of investigation in historic construction.