Chang-Jung Hsueh

Mr. Chang-Jung Hsueh


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2011 in Biosensors
Verified
Journal Article
Open access
PDF file
CHChang-Jung Hsueh
Chang-Jung Hsueh
JWJoanne H. Wang
Joanne H. Wang
LDLiming Dai
Liming Dai
Chung-Chiun LiuChung-Chiun Liu
Chung-Chiun Liu
Alanine aminotransaminase (ALT), is an enzyme that normally resides in serum and body tissues, especially in the liver. It is released into the serum as a result of tissue injury; hence the concentration of ALT in the serum may be increased with acute damage to hepatic cells. A single use, disposable biosensor, comprising iridium nano-particle as catalyst dispersed on carbon paste, has been developed for the determination of ALT concentration. The biosensor is based on quantifying H2O2 concentration produced by a serial of ALT enzymatic reactions. It operates well at room temperature in different physiological fluids: phosphate buffer, calf serum and human serum for ALT concentration of 0–544 ng/mL. Experimental results in human serum are compared to those obtained by spectrophotometric assays with excellent agreement. Therefore, the Ir/C biosensor shows good relationship on the dilution of concentrated ALT clinical applications.

29 May 2012 in Biosensors
Verified
Journal Article
Open access
PDF file
CHChang-Jung Hsueh
Chang-Jung Hsueh
JWJoanne H. Wang
Joanne H. Wang
LDLiming Dai
Liming Dai
Chung-Chiun LiuChung-Chiun Liu
Chung-Chiun Liu
Aspartate aminotransaminase (AST) is a hepatocelluar enzyme released into the bloodstream when hepatic cells are damaged, resulting in elevated blood levels of AST. A single use, disposable biosensor prototype, composed of catalytic iridium nano-particles dispersed on carbon paste, was developed to detect enzymatically-produced H2O2 in AST-mediated reactions. This biosensor is capable of measuring AST levels in a phosphate buffer and undiluted human serum over the concentration range of 0 to 0.89 μg/mL AST concentration (corresponding to 0–250 UL−1 specific activity). The biosensor operates at relatively low oxidation potential (+0.3 volt (V) versus the printed Ag/AgCl), minimizing any potential chemical interference in human serum. The measurements of AST in human serum using the biosensor compared well with those measured by standard hospital spectrophotometric assays. This Ir-C biosensor may be useful for AST measurements in the clinical environment.

25 September 2014
Verified
Book Chapter
Closed access
PDF file
CHChang-Jung Hsueh
Chang-Jung Hsueh
MJMetini Janyasupab
Metini Janyasupab
YLYing-Hui Lee
Ying-Hui Lee
Chung-Chiun LiuChung-Chiun Liu
Chung-Chiun Liu

25 September 2014
Verified
Book Chapter
Closed access
PDF file
CHChang-Jung Hsueh
Chang-Jung Hsueh
MJMetini Janyasupab
Metini Janyasupab
YLYing-Hui Lee
Ying-Hui Lee
Chung-Chiun LiuChung-Chiun Liu
Chung-Chiun Liu