The occurrence of a partial arc can affect insulation properties of the insulator by different types of flashover. In order to investigate the influence of a partial arc on electric field distribution along the catenary insulator string, a three-dimensional model of the cap-pin insulator string with partial arc was established in this paper. The electric field distribution along the insulator string when the arc extended on the insulator surface and bridged sheds was investigated based on the electric field analysis using the finite element method. The results showed that the occurrence of a partial arc caused obvious distortion of the electric field, which was a two-dimensional axis symmetrical field before arcing to a three-dimensional field. In the case of arc extension, the sudden rise of field intensity was mostly at the rib and the shed edge, which had the local maximum field intensity. The rib and the shed edge played a certain hindrance role in the extension of the arc. The main reason for promoting the development of the arc can be attributed to thermal ionization. In the case of arc bridge sheds, the highest field intensity appeared at the edge of the last bridged shed. As the number of sheds arc-bridged increased, the maximum field intensity also increased. As the arc length increased, the electric field intensity of the arc head also increased, which resulted in an accelerated arc development. The main factor to promote the development of the arc can be attributed to electrical breakdown. The measures to hinder the rapid development of partial arcs were proposed.
To solve the problem of contamination flashover of a catenary insulator in an electrified railway, the collision mechanism and deposition characteristics of contamination particles on the insulator surface should be studied to ensure the safe operation of traction power supply systems. This research used horizontal and oblique cantilever insulators as objects, and established the collision model between particles and insulator surface under different arrangements. The deposition conditions of particles on the insulator surface were obtained, and the simulation model of insulator contamination accumulation was established by using the Euler two-phase flow. The difference of contamination deposition characteristics between horizontal and oblique cantilever insulators was analyzed with the volume fraction of contamination particles as the characterization parameter. By comparing the cantilever insulator with the positive feeder insulator, this study analyzed the influence of shed structure on the contamination deposition characteristics. Results show that the installation method of an insulator has an impact on the contamination deposition on the insulator surface. When particle size and wind velocity are fixed, the degree of contamination accumulation on the surface of the oblique cantilever insulator is constantly higher than that of the horizontal cantilever insulator. The insulator shed structure also has a certain effect on the contamination deposition on the insulator surface. For the cantilever insulator, the degree of contamination accumulation of the windward side is higher than that of the leeward side. However, for the positive feeder insulator, the degree of contamination accumulation of the windward side is consistently less than that of the leeward side. Measures to deal with contamination flashover of catenary insulator are proposed.