It has been demonstrated by a large number of studies that microwave ignition can greatly extend the lean-burn limit in the internal combustion engines. This paper investigates the influence of the pulse period and duty cycle of pulsed microwave signals on the combustion performance of CH4-air mixtures during microwave ignition in a constant-volume combustion chamber for a lean-burn equivalence ratio $\varphi =0.6$ and the same energy input as for conventional spark ignition. Combustion performance was evaluated with respect to combustion pressure, lean-burn limit, OH concentration, initial flame kernel, and composition of combustion emissions. The results indicate that the duty cycle (i.e. average power) strongly influences the formation and development of the initial microwave discharge, while the pulsewidth influences the generation of non-equilibrium plasma which contributes to sustained combustion. The increasing the duty cycle can improve the ignition success rate, extend the lean-burn limit, and reduce the flame development time. Moderately increasing pulsewidth can further extend the lean-burn limit, particularly for elevated initial pressures.
Microwave plasma ignition has the potential for energy savings and emission reductions, and the minimum ignition energy (MIE) and the lean limit can be determined by microwave spark plugs (MSPs) under the same microwave power. To predict the relationship among electric field intensity (EFI), equivalence ratio (φ) and MIE, a physical model of microwave spark ignition is established. The calculation results show that the MIE has a U-shaped relationship with φ, and the MIE value of methane-air is minimum at the point of φ = 0.7. Then, a novel MSP with three different electrode structures and EFIs is enabled. Finally, this paper presents a combustion performance analysis focusing on the flame kernel, combustion pressure, and composition of combustion emissions. The results indicate that a larger flame kernel size, peak pressure in the chamber and higher fuel efficiency are all achieved under the condition of φ = 0.7 for the same MSP. On the one hand, the MIE of MSP 1 with a higher EFI is lower than that of MSPs 2 and 3; on the other hand, the experimental relationship between the MIE and φ is qualitatively similar to the theoretical prediction under microwave spark ignition in this paper.
To satisfy various requirements of different physics experiments, a new power modulation method of the lower hybrid wave (LHW) has been developed in Experimental Advanced Superconducting Tokamak (EAST), including the development of a control source combining software and hardware. Such modulation system is realized by the main positive-intrinsic-negative diode switch located at the oscillator. The LHW modulation system has been installed and tested, demonstrating that the modulation parameters can be controlled flexibly. The maximal modulation frequency is about 10 kHz, which is limited by the hardware circuit speed. The system has been successfully used to study the influence of LHW on the performances of plasma. Under the modulation of LHW, strong mitigation of edge-localized modes (ELMs) has been observed, and ELM pace-making technique has been demonstrated. Further experimental studies with the modulation system will be continued in EAST.
Systematic characterization of the amplitude–phase response of microwave power amplifier modules with independent amplitude and phase control functions is important for device evaluation, parameter setting, and engineering applications. Measurements at limited operating points cannot adequately capture response variations over prescribed ranges of input power and control voltage or support repeated measurements across multiple parameter combinations. A parameter-configurable automated measurement method is proposed. Input power, Pin, amplitude control voltage, VA, and phase control voltage, VP, are defined as configurable variables, and a deterministic measurement sequence is generated from user-defined start values, step sizes, and maximum values. At each measurement point, after a preset delay following the control-state update, a vector network analyzer (VNA) simultaneously acquires magnitude and phase within the same measurement operation. The corresponding VNA-link power PVNA and output phase φout are recorded as a structured response dataset for reconstructing power- and phase-response curves during post-processing. The method is implemented using a vector network analyzer, directional coupler, power-detection module, and data-acquisition unit. Repeated measurements under identical parameter configurations assess response repeatability, while an auxiliary detector branch monitors measurement-chain status. Power-response deviations are generally less than 0.03 dB, with a maximum of ∼0.07 dB, and phase deviations remain on the order of 1°. Validation using a single module indicates that the proposed method enables parameter-configurable and repeatable amplitude–phase response characterization under the tested conditions.