Movement science investigating muscle and tendon functions during locomotion utilizes commercial ultrasound imagers built for medical applications. These limit biomechanics research due to their form factor, range of view, and spatio-temporal resolution. This review systematically investigates the technical aspects of applying ultrasound as a research tool to investigate human and animal locomotion. It provides an overview on the ultrasound systems used and of their operating parameters. We present measured fascicle velocities and discuss the results with respect to operating frame rates during recording. Furthermore, we derive why muscle and tendon functions should be recorded with a frame rate of at least 150 Hz and a range of view of 250 mm. Moreover, we analyze why and how the development of better ultrasound observation devices at the hierarchical level of muscles and tendons can support biomechanics research. Additionally, we present recent technological advances and their possible application. We provide a list of recommendations for the development of a more advanced ultrasound sensor system class targeting biomechanical applications. Looking to the future, mobile, ultrafast ultrasound hardware technologies create immense opportunities to expand the existing knowledge of human and animal movement.
Focal vibration therapy seeks to restore the physiological function of tissues and the nervous system. Recommendations for vibration settings, e.g., that could improve residual limb health and prosthesis acceptance in people with amputation, are pending. To establish a physiological connection between focal vibration settings, clinical outcomes, and molecular and neuronal mechanisms, we combined the literature on focal vibration therapy, vibrotactile feedback, mechanosensitive Piezo ion channels, touch, proprioception, neuromodulation, and the recovery of blood vessels and nerves. In summary, intermittent focal vibration increases endothelial shear stress when applied superficially to blood vessels and tissues and triggers Piezo1 signaling, supporting the repair and formation of blood vessels and nerves. Conversely, stimulating Piezo1 in peripheral axon growth cones could reduce the growth of painful neuromas. Vibrotactile feedback also creates sensory inputs to the motor cortex, predominantly through Piezo2-related channels, and modulates sensory signals in the dorsal horn and ascending arousal system. Thus, sensory feedback supports physiological recovery from maladaptations and can alleviate phantom pain and promote body awareness and physical activity. We recommend focal vibration of phantom limb maps with frequencies from ~60–120 Hz and amplitudes up to 1 mm to positively affect motor control, locomotion, pain, nerves, and blood vessels while avoiding adverse effects.
Background and Objectives: After major upper-limb amputation, people face challenges due to losing tactile information and gripping function in their hands. While vision can confirm the success of an action, relying on it diverts attention from other sensations and tasks. This case report presents a 30-year-old man with traumatic, complete vision loss and transradial left forearm amputation. It emphasizes the importance of restoring tactile abilities when visual compensation is impossible. Materials and Methods: A prototype tactile feedback add-on system was developed, consisting of a sensor glove and upper arm cuff with related vibration actuators. Results: We found a 66% improvement in the Box and Blocks test and an overall functional score increase from 30% to 43% in the Southampton Hand Assessment Procedure with feedback. Qualitative improvements in bimanual activities, ergonomics, and reduced reliance on the unaffected hand were observed. Incorporating the tactile feedback system improved the precision of grasping and the utility of the myoelectric hand prosthesis, freeing the unaffected hand for other tasks. Conclusions: This case demonstrated improvements in prosthetic hand utility achieved by restoring peripheral sensitivity while excluding the possibility of visual compensation. Restoring tactile information from the hand and fingers could benefit individuals with impaired vision and somatosensation, improving acceptance, embodiment, social integration, and pain management.
5 May 2018 in European Journal of Applied Physiology
This study investigated the effect of isometrically induced fatigue on Hill-type muscle model parameters and related task-dependent effects. Parameter identification methods were used to extract fatigue-related parameter trends from isometric and ballistic dynamic maximum voluntary knee extensions. Nine subjects, who completed ten fatiguing sets, each consisting of nine 3 s isometric maximum voluntary contractions with 3 s rest plus two ballistic contractions with different loads, were analyzed. Only at the isometric task, the identified optimized model parameter values of muscle activation rate and maximum force generating capacity of the contractile element decreased from \(20.8 \pm 8.4\) to \(11.2 \pm 4.1\) Hz and from \(18{,}137 \pm 150\) to \(10{,}666 \pm 2139\) N, respectively. For all tasks, the maximum efficiency of the contractile element, mathematically related to the curvature of the force–velocity relation, increased from \(0.35 \pm 0.04\) to \(0.42 \pm 0.05\). The model parameter maximum contraction velocity decreased from \(0.93 \pm 0.1\) to \(0.9 \pm 0.1\) m/s and the stiffness of the serial elastic element from \(1936 \pm 227\) to \(1432 \pm 245\) N/mm. Thus, models of fatigue should consider fatigue dependencies in active as well as in passive elements, and muscle activation dynamics should account for the task dependency of fatigue.
Until now direct localization of motor endplates for any arbitrary muscle structure was reserved to cadaver studies or restricted to specific muscles in-vivo. Utilizing ultrafast ultrasound we report a versatile in-vivo method for the detection of motor endplate zones. To achieve this goal, we employ a research ultrasound system with a linear array transducer probe to record ultrasound images of electrically-stimulated medial gastrocnemius muscles. An optical flow speckle tracking algorithm is used to track the points along a single fascicle. We localize motor endplates at intersection points where mechanical contraction waves diverge bidirectionally towards the fiber ends. Contrary to common experimental methods, our proposed ultrafast ultrasound-based approach allows to localize motor endplates also in deep and pennate muscles in-vivo. These results open up new applications for ultrasound in neuromuscular research.
12 June 2017 in Mathematical and Computer Modelling of Dynamical Systems