Propagation characteristics of a detonation wave in an air-breathing rotating detonation combustor (RDC) using natural gas (NG)–hydrogen fuel blends is presented in this paper. Short-duration (∼up to 6 s) experiments were performed on a 152.4 mm OD uncooled RDC with two different annulus gap widths (5.08 mm and 7.62 mm) over a range of equivalence ratios (0.6–1.0) at varying inlet air temperatures (∼65–204 °C) and NG content (up to 15%) with precombustion operating pressure slightly above ambient. It was observed that the RDC, with an annulus gap width of 5.08 mm, was inherently unstable when NG was added to the hydrogen fuel while operating at precombustion pressures near ambient and at an inlet air temperature of 65 °C. Increasing the annulus gap width to 7.62 mm improved the stability of the detonation wave at similar temperatures and pressure permitting operation with as much as 5% NG by volume. While observed speeds of the detonation waves were still below theoretical values, an increase in inlet air temperature reduced the variability in wave speed. The frequency analysis thus explored in this study is an effort to quantify detonation instability in an RDC under varying operational envelope. The data presented are relevant toward developing strategies to sustain a stable detonation wave in an RDC using NG for land-based power generation.
Experimental and numerical investigation of internal cooling channels with rib turbulators is presented with sCO2 flow at pressure-20.7MPa and temperature up to 150°C. The effect of channel aspect ratio up to 2:1 on thermal-hydraulic performance is explored in additively manufactured rectangular and square channels, both with and without 60° ribs on the top and bottom sides. The Wilson-plot method is employed to measure channel averaged Nusselt number over a Reynolds number range up to 370,000. The friction factor and the overall thermal performance factor (TPF) are also reported. The computational fluid dynamics (CFD) simulation is performed for the rib-turbulated configurations reported in the experiments. The objective of the numerical study is to gain insight into the local heat transfer augmentation in the ribbed channels varying the aspect ratio, channel configuration, operating conditions and surface roughness. Surface roughness is simulated using sand grain roughness height (Ks) calculated from the experimental data, and a comparison is presented with varying surface roughness heights ranging between Ks = 0 - 40µm. Experimental results indicate that the heat transfer augmentation is negligible in the rectangular channels with ribs on the long side compared to the square channel. However, it is enhanced by 60% in comparison to placing ribs on the shorter side. The TPF remains constant at around 1 for the entire range of Reynolds numbers. The simulation results highlight that increased surface roughness can have a considerable influence on Nusselt number and overall TPF.