Jim Freihaut

Dr. Jim Freihaut


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2007 in Journal of Architectural Engineering
Verified
Journal Article
Closed access
BHB. Hu
B. Hu
JFJim Freihaut
Jim Freihaut
WBWilliam Bahnfleth
William Bahnfleth
PAP. Aumpansub
P. Aumpansub
BTB. Thran
B. Thran
Human activity is an important factor influencing particle resuspension in the indoor environment. This work studies the applicability of a multizone airflow and contaminant transport model (CONTAM 2.1) in the simulation of indoor dispersion of particles under human activity disturbance. An iterative method is suggested to complement CONTAM 2.1, by tracking the transient particle concentration on floor surface due to dynamic deposition and resuspension process. A three-zone building with a heating, ventilation, and air conditioning system is used as the simulation case to test the convergence and accuracy of this algorithm under different particle-release scenarios. The algorithm shows a very fast convergence speed in the simulation. Comparisons of calculation results between the multizone model and the analytical model show good agreement and verify the accuracy of the multizone model simulation. The airborne particle concentration profiles and human breathing dose are also analyzed for the three-zone bu...

20 June 2024 in Buildings
Verified
Journal Article
Open access
PDF file
HMHomeira Mirhosseini
Homeira Mirhosseini
JLJie Li
Jie Li
LILisa Domenica Iulo
Lisa Domenica Iulo
JFJim Freihaut
Jim Freihaut
In response to escalating energy demands and global warming concerns, the Passive House Standard has emerged as a solution in residential construction, aiming to drastically reduce energy consumption and operational costs primarily through high-performance building envelopes. While a considerable volume of the literature has focused on the Passivhaus Institute (PHI) standards, predominantly in European contexts, there is a gap in research on the Passive House Institute US (Phius) standards, particularly in North American climates. This study conducts a quantitative comparative analysis of two adjacent multifamily residential buildings in Central Pennsylvania, Climate Zone 5A—one built using conventional construction methods and the other following Passive House (PHIUS+ 2015) certification standards—to validate the energy efficiency improvements attributed to Passive House designs. A comparative analysis of the whole building energy use over two years reveals that the Passive House building consumes approximately 50% less energy than its conventional counterpart in terms of whole building energy use and the national median recommended benchmark metric defined by the Energy Star Portfolio Manager. These findings emphasize the potential for significant energy savings and greenhouse gas reductions in residential buildings, highlighting the necessity for policymakers and governments to incentivize the adoption of Passive House standards to achieve environmental sustainability and reduce energy costs for society.

1 September 2009 in Journal of Architectural Engineering
Verified
Journal Article
Closed access
JAE-WEON JEONGJAE-WEON JEONG
JAE-WEON JEONG
JBJustin Bem
Justin Bem
WBWilliam Bahnfleth
William Bahnfleth
JFJim Freihaut
Jim Freihaut
BTBrandolyn Thran
Brandolyn Thran
Literature on aerosol behavior in conventional heating ventilating and air conditioning duct systems that is directly applicable to modeling and simulation of deposition and resuspension of particulate matter is reviewed. Open literature discussing particle resuspension from duct surfaces is rare and most studies investigating particle deposition consider only clean duct surfaces. There is a similar lack of studies on particle deposition and resuspension in mechanical components found in air distribution systems (e.g., heat exchangers, fans, dampers, etc.) and in duct flows where the turbulent velocity profile is not fully developed. An example calculation of penetration through a simple duct system illustrates the characteristics of results produced by the identified modeling methods.

4 November 2019 in Energies
Verified
Journal Article
Open access
PDF file
PDParhum Delgoshaei
Parhum Delgoshaei
JFJim Freihaut
Jim Freihaut
Building-scale microgrids are a type of behind-the-meter microgrids where the building operator has control of the distributed energy resources, including, in this case, a natural gas-fired microturbine in addition to solar PV and battery energy storage systems. There is a growing trend in deploying behind-the-meter microgrids due to their benefits including the resiliency of serving critical loads, especially in regions with abundant natural gas. In order to ensure distributed energy resources are dispatched optimally for the desired mode of operation, a hierarchical control platform including a centralized controller was developed and installed. The platform includes communication and control infrastructure that interface with controllers for distributed energy resources and the building automation system of a recently built energy efficient commercial building. Based on desirable outcomes under different grid and building conditions, operational modes were defined for the microgrid controller. The controller is programmed to map each mode to respective operational modes for distributed energy resources controllers. Experimental data for test runs corresponding to two operational modes confirm the communication and control infrastructure can execute hierarchical control commands. Finally, dispatch optimization for a year-long simulation of system operation is presented and the benefits of the hybrid solar PV-natural gas setup are evaluated.

5 July 2023 in Journal of Photochemistry and Photobiology B: Biology
Verified
Journal Article
Closed access
LLLily X. Li
Lily X. Li
RNRuth H. Nissly
Ruth H. Nissly
ASAnand Swaminathan
Anand Swaminathan
IBIan M. Bird
Ian M. Bird
NBNina R. Boyle
Nina R. Boyle
WBWilliam P. Bahnfleth
William P. Bahnfleth

1 June 2007 in Journal of Architectural Engineering
Verified
Journal Article
Closed access
JFJoseph T. Firrantello
Joseph T. Firrantello
PAPonkamon Aumpansub
Ponkamon Aumpansub
WBWilliam Bahnfleth
William Bahnfleth
BHBin Hu
Bin Hu
JFJim Freihaut
Jim Freihaut
SHSherri Hutchens
Sherri Hutchens
This paper presents results from the simulation of localized, short-duration bioaerosol releases in a hypothetical building similar to a dormitory or barracks using public domain multizone air flow and contaminant dispersion modeling software. The primary purpose of the modeling was to generate example exposure data to be used in the development of a comprehensive microbial risk assessment methodology. However, these results are also of intrinsic interest for what they reveal about the contribution of various building characteristics to risk from airborne contaminants. A variety of parameters were varied, including building construction, heating, ventilating, and air-conditioning (HVAC) system design, and release characteristics, among others. Results of these simulations demonstrate the variability of exposure possible under different scenarios and, more particularly, the impact that HVAC design decisions can have on risk. Although a single building and restricted set of scenarios was investigated, several general conclusions could be drawn regarding factors, such as HVAC zoning and filter maintenance, that intrinsically contribute to vulnerability reduction.