Kleiton Sousa

Prof. Kleiton Sousa


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2016 in IEEE Sensors Journal
Verified
Journal Article
Closed access
RLRafael Pomorski Linessio
Rafael Pomorski Linessio
KSKleiton Sousa
Kleiton Sousa
TSThiago da Silva
Thiago da Silva
CBCarlos Alberto Bavastri
Carlos Alberto Bavastri
Paulo AntunesPaulo Antunes
Paulo Antunes
JSJean Carlos Cardozo Da Silva
Jean Carlos Cardozo Da Silva
In this paper, the implementation, characterization, calibration, and testing of a biaxial optical fiber accelerometer for vibration monitoring in three-phase induction motors is presented. The optical sensor uses fiber Bragg gratings to measure the displacement of an inertial mass relatively to a support base. The sensor characterization was measured through the impact hammer, allowing the determination of the natural frequencies in both sensitive directions, the values of 747.5 Hz and 757.5 Hz were estimated for the x-axis and the y-axis, respectively. For calibration, an electromagnetic exciter was used to introduce a controlled harmonic excitation at different frequencies, with this analysis, a high SNR was observed, on average over 30 dB for both sensitive directions, and a sensitivity of 100 pm × g -1 was obtained, up to one third of the natural frequency, in each direction. The tests were developed with the main aim of the analysis in induction motors based in vibration monitoring, the analysis can help to prevent wear in motors, increasing its efficiency, and lowering maintenance costs. The optical accelerometer measurements were compared with the ones from a capacitive sensor, during regular operation and with a broken rotor bar operating with 75% and 100% load. The performed tests with the optical sensor allowed to successfully analyze the frequency components, and its changes, for the regular and damage operation.

14 April 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
BBBeatriz Brusamarello
Beatriz Brusamarello
JSJean Carlos Cardozo Da Silva
Jean Carlos Cardozo Da Silva
KSKleiton Sousa
Kleiton Sousa
GGGiovanni Alfredo Guarneri
Giovanni Alfredo Guarneri
Due to its robustness and cost-effectiveness, the three-phase induction motor (TIM) has become the most widespread electric machine today. However, like any other equipment, it is vulnerable to a fault, and about 52% of these are related to bearings. This work presents the detection of flaws in the outer bearing’s raceway from the measurement of motor dynamic strain signals collected from sensors based on fiber Bragg grating (FBG). Three different degrees of severity were considered for faults in the outer bearing’s raceway. The tests were carried out on the motor operating under no-load conditions, with 47 different power supply frequencies. This work proposes a support vector machine (SVM) classifier to identify fault severity levels. Feature extraction was performed using two techniques: selecting the four highest peaks in the frequency spectrum and principal component analysis (PCA). The supervised SVM classifiers show that the dataset formed from the PCA presented a higher hit rate than the dataset constituted by the four highest peaks, with 99.82% and 92.73%, respectively. Based on the methodology presented in this work, it was possible to validate the use of FBG to detect bearing faults. Regardless of the degree of severity of the fault analyzed, the sensor detected its characteristic frequency. Based on the methodology presented in this work, it was possible to validate the use of FBG to detect bearing faults. Regardless of the degree of severity of the flaw analyzed, the sensor detected its characteristic frequency.

15 April 2016 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KSKleiton Sousa
Kleiton Sousa
UDUilian Jose Dreyer
Uilian Jose Dreyer
CMCicero Martelli
Cicero Martelli
JSJean Carlos Cardozo Da Silva
Jean Carlos Cardozo Da Silva
Mechanical and electrical forces of a three-phase induction motor (TIM), in operation, can cause strain in the stator, which may lead to frustrating vibration problems. These problems may greatly reduce reliability and ultimately lead to increased maintenance cost. This paper shows the method to overcome this problem by carrying out the dynamic strain measurement analysis in a TIM running at no-load condition, using an optical fiber sensor. The dynamic strain induced by mechanical and electrical forces was measured by using fiber Bragg gratings (FBGs), installed inside the motor, in between two stator teeth. The electromagnetic immunity and reduced size of the FBGs render them suitable for this application. The frequency components of the strain in TIM were predicted using a model of the forces present in the air gap, considering static and dynamic rotor eccentricities. Two TIM motors, one of 2-poles and the other of 4-poles, and each equipped with two FBGs strain sensors, were used. The sensors were positioned between two stator teeth, separated by 120° from each other in the 2-pole motor and 90° in the 4-pole motor. The experimental analysis shows that the frequency components of the dynamic force spectrum presented by the two motors are the same as those predicted theoretically. Rotor eccentricity was achieved by attaching an unbalanced load to the rotor shaft. The amplitude of vibration at rotor rotational frequency increased when the unbalanced load on the rotor shaft increased. The measurement presented in this paper can be used to determine some TIM parameters, such as the effect of the motor power supply on its vibration signal. It can also be used as a potential maintenance tool for the continuous monitoring of the TIM with high sensitivity.

2 July 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
GKGustavo Gomes Kuhn
Gustavo Gomes Kuhn
KSKleiton Sousa
Kleiton Sousa
CMCicero Martelli
Cicero Martelli
CBCarlos Alberto Bavastri
Carlos Alberto Bavastri
JSJean Carlos Cardozo Da Silva
Jean Carlos Cardozo Da Silva
This paper presents a new methodology for measuring vibration and temperature using fiber Bragg grating (FBG) sensors embedded in carbon fiber polymer attached directly on the iron core of a power transformer. The device has a quick-coupling clip design and is fabricated from a carbon fiber reinforced composite (CFRP) for robustness and flexibility. Temperature and vibration FBG sensors are embedded in the carbon fiber clip, which is easily and quickly coupled directly to the transformer iron core. In the low frequency ranges, from 0 to 500 Hz, vibrations are mainly generated in the core. Rigidity is controlled by clip thickness and geometry, since the system is designed to have a wide operating frequency range. The embedded strain FBG sensor sensitivity has been improved due to its spring-shaped design static and dynamic simulations applying the Finite Element Method (FEM) were performed to determine the optimal dimensions and structure of the part. The clip’s frequency response function (FRF) was assessed and tested by using three techniques: FEM harmonic analysis, mechanical impact testing, and optical FBG sensing. The results demonstrate a 3.94 % differential among the methods. A comparison was made of the power transformer’s FRF when fitted with a glued free FBG sensor and an embedded FBG sensor. In both cases, the transformer was subjected to varying electrical load conditions (no-load, linear, and nonlinear load). The results showed a 19 % average sensitivity improvement when the embedded sensor was compared to the free sensor.

19 April 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KSKleiton Sousa
Kleiton Sousa
ICIgor Brutkowski Vieira da Costa
Igor Brutkowski Vieira da Costa
EMEdnilson Soares Maciel
Ednilson Soares Maciel
JRJoaquim Eloir Rocha
Joaquim Eloir Rocha
CMCicero Martelli
Cicero Martelli
JSJean Carlos Cardozo Da Silva
Jean Carlos Cardozo Da Silva
In this paper, the dynamic strain measurement of a four-pole induction motor stator operating at 75% and 100% of the rated load is used to detect a broken rotor bar. Four fiber Bragg grating (FBG) strain sensors are installed inside the motor, between two stator teeth. Electromagnetic immunity and decreased size of the FBGs make them suitable for this application. When a broken bar is present, some characteristic frequencies in the stator strain spectrum appear. The values of these frequencies are proportional to the motor slip. Instrumentation allows the diagnosis of the broken bar in two different regions of the stator strain frequency spectrum: first, near the rotational frequency, and second, close to twice as much the supply frequency. Two different supply conditions are presented, feeding the motor from an electrical grid and by using a variable-frequency driver. The experimental results indicate that the broken rotor bar can be detected in all supply situations by using the two regions of the stator strain spectrum. By using the method presented in this paper, the broken rotor bar can be detected, even with a harmonic distortion in voltage. This is an advantage over the classic motor current signature analysis method.

25 July 2012 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KSKleiton Sousa
Kleiton Sousa
AHAngelo A. Hafner
Angelo A. Hafner
HKHypolito José Kalinowski
Hypolito José Kalinowski
JSJean Carlos Cardozo Da Silva
Jean Carlos Cardozo Da Silva
Fiber Bragg grating (FBG) sensors are used to investigate the temperature dynamics of a three-phase induction motor under different supply conditions and also during startup. The temperature field distribution is monitored using eight uniformly distributed FBGs in the stator. Tests are performed with the motor running at no load and with intentional voltage disturbances in the motor feed. It is observed that the temperature distribution in the stator is not uniform either with or without a balanced voltage in the windings. An average level increase in temperature of 0.5$^{\circ}{\rm C}$ is registered for all of the sensors and associated with the unbalanced voltage in the windings. The motor under the test is kept at synchronous speed and connected to a second motor to determine the temperature rise due to mechanical and stator losses. An increase in temperature of 4.5$^{\circ}{\rm C}$ due to mechanical losses is registered as well as an increase of 15.5$^{\circ}{\rm C}$ due to stator winding and stator iron losses.