A truss arch tower is a large-span arch structure with multiple skewbacks. This tower is made of a large number of members with unique form, and contains more than five kinds of geometric features. The wind forces and the corresponding wind effects on the truss arch tower are notably complicated. In this study, wind tunnel tests were conducted to evaluate the wind forces on the steel latticed structure mentioned above using the high-frequency base balance technique. Four segmental models, including one arch foot of main truss, two arch feet of sub-truss, and one arch crown of main truss were tested in nominally smooth flow. The drag forces were measured and compared with several existing codes, including the British, American, and Chinese codes. The incidence angle effects and the interference effects on the drag coefficient were analyzed. The testing results showed that the direction of the wind forces has a marked effect on the whole truss tower. The solidity ratio and layout of the segmental models, including the cross-section and the centerline of the members, have critical effects on the drag forces.
1 July 2021 in Journal of Wind Engineering and Industrial Aerodynamics
The uncertainty of the parameters involved in the bridge vortex-induced vibration (VIV) response is hard to be described accurately and the probabilistic description remains scarce. The present work aims at giving a contribution to the probabilistic evaluation of the bridge VIV response considering uncertainty influence of parameters. A self-anchored suspension bridge was selected as an example to analyze the uncertainty influence on the probabilistic evaluation of VIV response. The probability density function of the wind speed at the deck level of the bridge was established. The modal analysis was carried out and the natural vibration characteristics were checked. Then three performance functions involving different considerations of the maximum response models of bridge VIV were introduced. The numerical characteristics (coefficient of variation (COV), skewness and kurtosis) in the parameter space was propagated to access its influence on the exceeding probability of the bridge VIV response utilizing the second-order fourth-moment (SOFM) method. The influence from the different distribution type of the parameters was investigated. Results showed that the influence degree of COV, skewness and kurtosis of parameters on the exceeding probability of VIV response for the bridge is different and the distribution type of parameter has little effect based on the SOFM method.
To investigate the suppression effect of three baffle plate configurations (BP1, BP2, and BP3) within slot region on vertical vortex-induced vibration (VIV) of a separated twin-box girder, with emphasis on spanwise correlation dynamics of the vortex-excited aerodynamic lifts (VEALs). Wind tunnel tests on a spring-suspended sectional model were conducted. The results show that the installation of baffle plates, particularly BP3, significantly reduced the vertical VIV amplitudes and lock-in regions, but increased the onset wind velocity of the separated twin-box girder. It also decreases steady pressure, fluctuating pressure and lift force. The phenomenon directly correlates with the disruption of vortex shedding in the slot region and the top/bottom plates of the downstream box girder. These disruptions predominantly result from flow separation occurring at the ancillary facilities and corner structures. The spanwise correlation coefficients are amplified by the amplitudes and exhibit a monotonic attenuation with increasing spanwise distance, asymptotically approaching a non-zero constant value. The corresponding decay rate demonstrates a substantial enhancement with diminishing VIV amplitude. The spanwise correlations of VEALs vary with baffle plate configuration, which are smaller than those without baffle plates. The variation of both spanwise configuration and transverse characteristic dimensions of the baffle plates can impact the spanwise correlation of VEALs. The VIV amplitude can be significantly reduced by appropriately decreasing the spanwise correlation coefficient of VEALs. Aerodynamic optimization of baffle plate configurations to reduce the spanwise correlation coefficient of VEALs could be an effective measure to mitigate VIV amplitude in twin-box girders.