Yves Olsommer

Mr. Yves Olsommer

Fraunhofer Institute for Biomedical Engineering, Sulzbach, Saarland, Germany
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2020 in Sensors
Verified
Journal Article
Open access
PDF file
YOYves Olsommer
Yves Olsommer
FIFrank R. Ihmig
Frank R. Ihmig
In recent years, the development of implantable electronics has been driven by the motivation to expand their field of application. The main intention is to implement advanced functionalities while increasing the degree of miniaturization and maintaining reliability. The intrinsic nonlinear properties of the electronic components, to be used anyway, could be utilized to resolve this issue. To master the implementation of functionalities in implantable electronics using the nonlinear properties of its electronic components, simulation models are of utmost importance. In this paper, we present a simulation model that is optimized in terms of consistency, computing time and memory consumption. Three circuit topologies of nonlinear capacitors, including hysteresis losses, are investigated. An inductively coupled measurement setup was realized to validate the calculations. The best results were obtained using the Trapezoid method in ANSYS with a constant step size and a resolution of 500 k points and using the Adams method in Mathcad with a resolution of 50 k points. An inductive coupling factor between 7% and 10% leads to a significant improvement in consistency compared to lower coupling factors. Finally, our results indicate that the nonlinear properties of the voltage rectifier capacitor can be neglected since these do not significantly affect the simulation results.

14 November 2019 in Proceedings
Verified
Conference Paper
Open access
PDF file
YOYves Olsommer
Yves Olsommer
FIFrank R. Ihmig
Frank R. Ihmig
CMCarsten Müller
Carsten Müller
For several years, the requirements on miniaturization of electronic implants with application in functional electrostimulation have been increasing, while functionality and reliability should not be impaired. One solution concept is to use neither active electronic components nor sensors or batteries. Instead, the functionalities are ensured by the use of intrinsic nonlinear properties of the already used components and energy is transferred by inductive coupling. In this paper, ceramic capacitors are investigated as a first step towards exploiting the nonlinear characteristics of ferroelectric materials. The ceramic capacitors are characterized by simulation and measurements. The modeling is carried out in Mathcad Prime 3.1 and ANSYS 2019 R2 Simplorer and different solvers are compared for exemplary calculations. Finally, a measurement setup is realized to validate the models. Calculations show that the trapezoid method with a number of 500 k points in the given solution interval is best suited for ANSYS. In Mathcad, the Adams, Bulirsch–Stoer, Backward Differentiation Formula, Radau5, and fourth order Runge–Kutta methods with an adaptive step width and a resolution of 50 k points are the most suitable. The nonlinear properties of ferroelectric materials in ceramic capacitors modeled with these methods using ANSYS and Mathcad show small and equal deviation from the measurements.

9 July 2021 in Electronic Materials
Verified
Journal Article
Open access
PDF file
YOYves Olsommer
Yves Olsommer
FIFrank R. Ihmig
Frank R. Ihmig
Currently, a large number of neurostimulators are commercially available for the treatment of drug-resistant diseases and as an alternative to pharmaceuticals. According to the current state of the art, such highly engineered electroceuticals require bulky battery units and necessitate the use of leads and extensions to connect the implantable electronic device to the stimulation electrodes. The battery life and the use of wired electrodes constrain the long-term use of such implantable systems. Furthermore, for therapeutic success and patient safety, it is of utmost importance to keep the stimulation current within a safe range. In this paper, we propose an implantable system design that consists of a low number of passive electronic components and does not require a battery. The stimulation parameters and power are transmitted inductively using an extracorporeal wearable transmitter at frequencies below 1 MHz. A simple circuit design approach is presented to achieve a closed-loop control of the stimulation current by exploiting the nonlinear properties of ferroelectric materials in ceramic capacitors. Twenty circuit topologies of series- and/or parallel-connected ceramic capacitors are investigated by measurement and are modeled in Mathcad. An approximately linear increase in the stimulation current, a stabilization of the stimulation current and an unstable state of the system were observed. In contrast to previous results, specific plateau ranges of the stimulation current can be set by the investigated circuit topologies. For further investigations, the consistency of the proposed model needs to be improved for higher induced voltage ranges.

1 October 2021 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
YOYves Olsommer
Yves Olsommer
FIFrank R. Ihmig
Frank R. Ihmig
Over the years, a constant progress in the development of implantable medical devices (IMD’s) can be observed. On one hand, the advanced implantable electronics enable the implementation of numerous smart functionalities, on the other hand, the variety of electronic components including sensors and a bulky battery severely restrict their degree of miniaturization and reliability. To overcome this limitation, our approach is to realize smart functionalities in leadless and battery-free IMD’s emerging from frugal innovation by exploiting the intrinsic nonlinear properties of the components to be used anyway. The aim of this work is to deepen the understanding of the dynamic behavior of circuit topologies of nonlinear ferroelectric ceramic capacitors and to investigate their potential use for an embedded closed-loop control of the stimulation current. We characterized a selection of 40 commercial ceramic capacitors by measurement and simulation. The degree of nonlinearity resulting from a circuit topology consisting of one, two series and two parallel connected nonlinear capacitors was modeled and evaluated in Mathcad. We present a model with parameterized nonlinear capacitors to simulate the dynamic behavior of an inductively coupled implantable system. The stabilization and amplitude of the stimulation current is controlled by two features. These features are in turn controlled by the circuit topology and the degree of nonlinearity of the capacitors. We found that a high degree of nonlinearity allows the stimulation current to be stabilized within a reasonable range, but it makes the system more prone to instability. However, our model needs to include the dynamic behavior of ferroelectric materials used as dielectric in ceramic capacitors to extend the current investigations and to deepen the understanding of the physics behind the nonlinear properties of ferroelectric capacitors.

1 February 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Open access
YOYves Olsommer
Yves Olsommer
FIFrank R. Ihmig
Frank R. Ihmig
Gianluca RizzelloGianluca Rizzello
Gianluca Rizzello
In this article, we present a physics-based model for nonlinear and hysteretic ferroelectric capacitors in inductively coupled microstimulator circuits. The purpose of this model is to predict the system's dynamic response as a function of the dielectric material properties, with the aim of optimizing the performance in passive power control applications. We describe the workflow starting from the extraction of the dielectric material properties of commercial ceramic capacitors to the implementation into the physics-based model of the overall circuit. Selected capacitors were experimentally characterized at frequencies above 100 kHz by means of both small signals (5 mV rms , ±25 V dc , and ±40 V dc ) and large signals (±25 V ac and ±40 V ac ). Our results show that the developed model is well suited for accurately predicting the circuit's stimulation current for highly nonlinear capacitors and exhibits higher precision compared to commonly used models based on differential capacitance. Preliminary in vitro measurement results are finally described to provide proof of concept of the envisioned model-based passive power control in implantable microstimulators.