Vânia Oliveira

Mrs. Vânia Oliveira


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2017 in Archives of Disease in Childhood - Fetal and Neonatal Edition
Verified
Journal Article
Open access
PDF file
PLPeter J Lally
Peter J Lally
Paolo MontaldoPaolo Montaldo
Paolo Montaldo
VOVânia Oliveira
Vânia Oliveira
RSRavi Shankar Swamy
Ravi Shankar Swamy
ASAung Soe
Aung Soe
STSudhin Thayyil
Sudhin Thayyil
We examined the brain injury and neurodevelopmental outcomes in a prospective cohort of 10 babies with mild encephalopathy who had early cessation of cooling therapy. All babies had MRI and spectroscopy within 2 weeks after birth and neurodevelopmental assessment at 2 years. Cooling was prematurely discontinued at a median age of 9 hours (IQR 5–13) due to rapid clinical improvement. Five (50%) had injury on MRI or spectroscopy, and two (20%) had an abnormal neurodevelopmental outcome at 2 years. Premature cessation of cooling therapy in babies with mild neonatal encephalopathy does not exclude residual brain injury and adverse long-term neurodevelopmental outcomes. This study refers to babies recruited into the MARBLE study (NCT01309711, pre-results stage).

Pedro ParreiraPedro Parreira
Pedro Parreira
BSBeatriz Serambeque
Beatriz Serambeque
Paulo Santos-CostaPaulo Santos-Costa
Paulo Santos-Costa
LMLisete Mónico
Lisete Mónico
VOVânia Oliveira
Vânia Oliveira
ASAnabela Salgueiro-Oliveira
Anabela Salgueiro-Oliveira
Reusable tourniquets and conventional securement dressings are considered risk factors for the occurrence of reported complications and catheter-related bloodstream infections. This study’s purpose is to assess the impact of single-use disposable tourniquets and advanced occlusive polyurethane dressings with reinforced cloth borders on peripheral intravenous catheter (PIVC)-related complications and contamination. A pre- and post-interventional prospective observational study was conducted in a cardiology ward of a tertiary hospital between April 2018 and February 2019. Overall, demographic and clinical data from 156 patients and PIVC-related outcomes were collected (n = 296) as well as PIVC tips for microbiological analysis (n = 90). In the pre-intervention phase (n = 118), complication rates of 62.1% were reported, while 44.1% of the PIVCs were contaminated (n = 34). In the post-intervention phase (n = 178), complication rates decreased to 57.3%, while contamination rates significantly decreased to 17.9% (p = 0.014; n = 56). Through a logistic regression, it was found that the use of innovative technologies reduces the chance of PIVC contamination by 79% (odds ratio (OR): 0.21; 95% confidence interval (CI): 0.05–0.98; p = 0.046). Meanwhile, PIVC-related complications and fluid therapy emerged as predictors for PIVC contamination. Findings suggest that the adoption of these innovative devices in nurses’ practice contributes to the significant reduction of PIVC contamination.

1 January 2019 in Revista Latino-Americana de Enfermagem
Verified
Journal Article
Open access
PDF file
ASAnabela Salgueiro-Oliveira
Anabela Salgueiro-Oliveira
Paulo Santos-CostaPaulo Santos-Costa
Paulo Santos-Costa
LBLuciene Braga
Luciene Braga
JGJoão Graveto
João Graveto
VOVânia Oliveira
Vânia Oliveira
Pedro ParreiraPedro Parreira
Pedro Parreira
Objetivos durante a punção venosa periférica, recomenda-se o uso de um garrote acima do local da punção para potencializar a distensão venosa. Dadas as suas características e o uso em ambientes clínicos, os garrotes podem representar uma fonte de disseminação de micro-organismos. Entretanto, os resultados de estudos científicos nessa área estão dispersos na literatura. Esta revisão de escopo tem como objetivo mapear as evidências disponíveis a respeito das práticas dos profissionais de saúde no que concerne ao uso do garrote durante a punção venosa periférica e à contaminação microbiológica associada. Método revisão de escopo de acordo com a metodologia do Instituto Joanna Briggs. Dois revisores independentes analisaram a relevância dos estudos, extraíram e sintetizaram dados. Resultados quinze estudos foram incluídos na revisão. Em geral, os garrotes foram reutilizados sem processos de descontaminação recorrentes. Verificou-se que os profissionais compartilham esses dispositivos entre si e os usaram continuamente por períodos entre duas semanas e sete anos e meio. Conclusão as práticas de enfermagem relacionadas ao uso do garrote durante a punção venosa periférica não são uniformes. A reutilização de garrotes pode colocar em risco a segurança do paciente se o reprocessamento (limpeza e desinfecção/esterilização) não for adequado, dado o tipo de material do garrote e a microbiota encontrada. Novos estudos são necessários para avaliar o impacto de vários tipos de práticas de reprocessamento na descontaminação de garrotes e na segurança do paciente.

9 March 2023 in Microorganisms
Verified
Journal Article
Open access
PDF file
NONádia Osório
Nádia Osório
VOVânia Oliveira
Vânia Oliveira
MCMaria Inês Costa
Maria Inês Costa
Paulo Santos-CostaPaulo Santos-Costa
Paulo Santos-Costa
BSBeatriz Serambeque
Beatriz Serambeque
ASAnabela Salgueiro-Oliveira
Anabela Salgueiro-Oliveira
Peripheral venous catheters (PVCs) are the most used vascular access devices in the world. However, failure rates remain considerably high, with complications such as PVC-related infections posing significant threats to patients’ well-being. In Portugal, studies evaluating the contamination of these vascular medical devices and characterizing the associated microorganisms are scarce and lack insight into potential virulence factors. To address this gap, we analyzed 110 PVC tips collected in a large tertiary hospital in Portugal. Experiments followed Maki et al.’s semi-quantitative method for microbiological diagnosis. Staphylococcus spp. were subsequently studied for the antimicrobial susceptibility profile by disc diffusion method and based on the cefoxitin phenotype, were further classified into strains resistant to methicillin. Screening for the mecA gene was also done by a polymerase chain reaction and minimum inhibitory concentration (MIC)-vancomycin as determined by E-test, proteolytic and hemolytic activity on skimmed milk 1% plate and blood agar, respectively. The biofilm formation was evaluated on microplate reading through iodonitrotetrazolium chloride 95% (INT). Overall, 30% of PVCs were contaminated, and the most prevalent genus was Staphylococcus spp., 48.8%. This genus presented resistance to penicillin (91%), erythromycin (82%), ciprofloxacin (64%), and cefoxitin (59%). Thus, 59% of strains were considered resistant to methicillin; however, we detected the mecA gene in 82% of the isolates tested. Regarding the virulence factors, 36.4% presented α-hemolysis and 22.7% β-hemolysis, 63.6% presented a positive result for the production of proteases, and 63.6% presented a biofilm formation capacity. Nearly 36.4% were simultaneously resistant to methicillin and showed expression of proteases and/or hemolysins, biofilm formation, and the MIC to vancomycin were greater than 2 µg/mL. Conclusion: PVCs were mainly contaminated with Staphylococcus spp., with high pathogenicity and resistance to antibiotics. The production of virulence factors strengthens the attachment and the permanence to the catheter’s lumen. Quality improvement initiatives are needed to mitigate such results and enhance the quality and safety of the care provided in this field.

1 January 2018 in Revista Brasileira de Enfermagem
Verified
Journal Article
Open access
PDF file
JGJoão Graveto
João Graveto
CSCristina Santos
Cristina Santos
Paulo Santos-CostaPaulo Santos-Costa
Paulo Santos-Costa
EFElisabete Fernandes
Elisabete Fernandes
Susana AlaricoSusana Alarico
Susana Alarico
VOVânia Oliveira
Vânia Oliveira
Descriptors: Health Services Administration; Hand Hygiene; Nurses; Infection Control; Public Health Nursing

8 February 2020 in Infectio
Verified
Journal Article
Open access
PDF file
ASAnabela Salgueiro-Oliveira
Anabela Salgueiro-Oliveira
VOVânia Oliveira
Vânia Oliveira
Paulo Santos-CostaPaulo Santos-Costa
Paulo Santos-Costa
FGFernando Gama
Fernando Gama
JGJoão Graveto
João Graveto
NONádia Osório
Nádia Osório
Introduction: The tourniquet used in venipuncture appears as a potential vehicle for the transmission of microorganisms that interferes with safety and the quality of clinical services. Objective: Mapping the scientific evidence on the microbiological contamination of the tourniquets used in peripheral venipuncture. Methodology: Scoping review following the Joanna Briggs Institute methodology.Results: 20 studies have been included, in which of 1477 tourniquets were analyzed. The rates of microbiological contamination varied between 10-100% and 19 studies reported the presence of S. aureus, 11 of them detected methicillin-resistant strains with prevalence between 3.3-58.3%. Conclusion: The contamination rate in the majority of studies was ≥70%, including 4 studies which had sampled ≥100 tourniquets. The evidence of our study is that the tourniquets are reservoirs of potential pathogens and can be transmitted to patient on staff hands. We recommend studies that confirm the reusable tourniquets can be responsible to healthcare associated infections.