Vlad Badilita

Dr. Vlad Badilita

Spin & Photon Application (SPA) Lab, Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2012 in Soft Matter
Verified
Journal Article
Closed access
PDF file
VBVlad Badilita
Vlad Badilita
RMRobert Ch. Meier
Robert Ch. Meier
NSNils Spengler
Nils Spengler
Ulrike WallrabeUlrike Wallrabe
Ulrike Wallrabe
MUMarcel Utz
Marcel Utz
JKJan Korvink
Jan Korvink
Nuclear magnetic resonance spectroscopy (NMR) and imaging (MRI) are important non-destructive investigative techniques for soft matter research. Continuous advancements have not only lead to more sensitive detection, and new applications, but have also enabled the shrinking of the detectable volume of sample, and a reduction in time needed to acquire a spectrum or image. At the same time, advances in microstructuring and on-chip laboratories have also continued unabated. In recent years these two broad areas have been productively joined into what we term micro nuclear magnetic resonance (μMR), an exciting development that includes miniaturized detectors and hyphenation with other laboratory techniques, for it opens up a range of new possibilities for the soft matter scientist. In this paper we review the available miniaturization technologies for NMR and MRI detection, and also suggest a way to compare the performance of the detectors. The paper also takes a close look at chip-laboratory augmented μMR, and applications within the broad soft matter area. The review aims to contribute to a better understanding of both the scientific potential and the actual limits of μMR tools in the various interdisciplinary soft matter research fields.

5 January 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
NSNils Spengler
Nils Spengler
JHJens Höfflin
Jens Höfflin
AMAli Moazenzadeh
Ali Moazenzadeh
DMDario Mager
Dario Mager
NMNeil MacKinnon
Neil MacKinnon
JKJan Korvink
Jan Korvink
We present a completely revised generation of a modular micro-NMR detector, featuring an active sample volume of ∼ 100 nL, and an improvement of 87% in probe efficiency. The detector is capable of rapidly screening different samples using exchangeable, application-specific, MEMS-fabricated, microfluidic sample containers. In contrast to our previous design, the sample holder chips can be simply sealed with adhesive tape, with excellent adhesion due to the smooth surfaces surrounding the fluidic ports, and so withstand pressures of ∼2.5 bar, while simultaneously enabling high spectral resolution up to 0.62 Hz for H2O, due to its optimised geometry. We have additionally reworked the coil design and fabrication processes, replacing liquid photoresists by dry film stock, whose final thickness does not depend on accurate volume dispensing or precise levelling during curing. We further introduced mechanical alignment structures to avoid time-intensive optical alignment of the chip stacks during assembly, while we exchanged the laser-cut, PMMA spacers by diced glass spacers, which are not susceptible to melting during cutting. Doing so led to an overall simplification of the entire fabrication chain, while simultaneously increasing the yield, due to an improved uniformity of thickness of the individual layers, and in addition, due to more accurate vertical positioning of the wirebonded coils, now delimited by a post base plateau. We demonstrate the capability of the design by acquiring a 1H spectrum of ∼ 11 nmol sucrose dissolved in D2O, where we achieved a linewidth of 1.25 Hz for the TSP reference peak. Chemical shift imaging experiments were further recorded from voxel volumes of only ∼ 1.5nL, which corresponded to amounts of just 1.5 nmol per voxel for a 1 M concentration. To extend the micro-detector to other nuclei of interest, we have implemented a trap circuit, enabling heteronuclear spectroscopy, demonstrated by two 1H/13C 2D HSQC experiments.

21 April 2010 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
VBVlad Badilita
Vlad Badilita
KKKai Kratt
Kai Kratt
NBNicoleta Baxan
Nicoleta Baxan
MMMohammad Mohmmadzadeh
Mohammad Mohmmadzadeh
TBTobias Burger
Tobias Burger
Ulrike WallrabeUlrike Wallrabe
Ulrike Wallrabe
We present for the first time a fully MEMS-integrated technology to manufacture 3D geometrically perfect solenoidal microcoils for microscale MRI applications. We report 25 µm isotropic resolution MR images of a copper sulfate aqueous phantom. These images are acquired using microcoils with 5 windings of insulated 25 µm diameter Au wire and with quality factors as high as 46 at the operating frequency (400 MHz).

20 February 2014 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
NSN Spengler
N Spengler
AMA Moazenzadeh
A Moazenzadeh
RMR Ch Meier
R Ch Meier
VBVlad Badilita
Vlad Badilita
JKJan Korvink
Jan Korvink
Ulrike WallrabeUlrike Wallrabe
Ulrike Wallrabe

25 March 2014 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
RMRobert Ch Meier
Robert Ch Meier
JHJens Höfflin
Jens Höfflin
VBVlad Badilita
Vlad Badilita
Ulrike WallrabeUlrike Wallrabe
Ulrike Wallrabe
JKJan Korvink
Jan Korvink

23 December 2011 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
OGOliver G. Gruschke
Oliver G. Gruschke
NBNicoleta Baxan
Nicoleta Baxan
LCLars Clad
Lars Clad
KKKai Kratt
Kai Kratt
DEDominik von Elverfeldt
Dominik von Elverfeldt
JKJan Korvink
Jan Korvink
We present a lab on a chip (LOC) compatible modular platform for magnetic resonance (MR)-based investigation of sub-millimetre samples. The platform combines the advantages offered respectively by microcoils (high resolution at the microscale) and macroscopic surface coils (large field of view) as MR-detectors and consists of a phased array of microcoils (PAMs) providing a flat MR-sensitive area of 18.3 mm2 with a B0-field uniformity better than 0.25 ppm in the sensor centre area. We demonstrate both high-resolution magnetic resonance imaging (MRI) and NMR spectroscopy using this platform. To demonstrate the application for biological samples, we report MR imaging of fish oocytes with an in-plane resolution of 30 × 30 μm2 and a contrast to noise ratio of 10 for a scan time of only 13 min 39 s. We have also demonstrated high-resolution spectroscopy of a water phantom achieving 11 ppb (4.5 Hz at 400 MHz) linewidth and an SNR of 28 for only 12 s scan time. State of the art automatic wire bonding technology in conjunction with MEMS techniques has been employed to manufacture the platform with potential applications in MR-investigation of planar samples.