Ben Xu

Dr. Ben Xu


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
ZWZhaokun Wang
Zhaokun Wang
DWDongning Wang
Dongning Wang
FYFan Yang
Fan Yang
LLLiujiang Li
Liujiang Li
CZChunliu Zhao
Chunliu Zhao
ZFZhanjun Fang
Zhanjun Fang
A mode-locked all-fiber laser based on nonlinear multimode interference effect of the graded index fiber (GIMF) is proposed and demonstrated. The saturable absorber (SA) used in the laser consists of a step index multimode fiber connected by a graded index multimode fiber. Compared with the theoretically proposed SMF-GIMF-SMF structure, the introduction of the step index multimode fiber (SIMF) eliminates the restriction on the length of GIMF and provides a more flexible method of making a SA based on the NL-MMI. Through bending the device to a certain state, the modulation depth of the SA was measured to be 3.16%. The mode-locked laser output pulses have the pulse width of ~446 fs, bandwidth of 4.48 nm at the fundamental repetition rate of 11.73 MHz. This versatility and simplicity of the SA device combined with the possibility of scaling the pulse energy in large mode area double clad fiber laser make it highly attractive in ultrafast photonics.

27 June 2023 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
XMXingchao Ma
Xingchao Ma
FZFengping Zhao
Fengping Zhao
BXBen Xu
Ben Xu
CZChunliu Zhao
Chunliu Zhao
HCHuifang Chen
Huifang Chen
SJShangzhong Jin
Shangzhong Jin
A high-sensitivity and fast-response relative humidity (RH) sensor based on a fiber-tip interferometer coated with agarose gel is proposed and demonstrated. To fabricate the interferometer, focusing the femtosecond laser on the fiber core near the end face of a well cleaved single-mode fiber (SMF) for less than 0.1 second to create a tiny refractive index-modulated dot is enough, then a thin film of hydrophilic material (agarose gel) is deposited on the end facet of the SMF. Owing to a high RI sensitivity of the interferometer and a humidity-induced refractive index (RI) change in the agarose gel, the fiber-tip sensor is qualified for RH sensing. The experimental results show that the sensor is extremely sensitive to high RH, with a maximum sensitivity of −2.04 dB/%RH and 0.673 nm/%RH at 90%RH. Furthermore, it exhibits low hysteresis as demonstrated by a breath monitoring of about 60 ms ultrafast response time and 160 ms recovery time. Additionally, it also shows a good long-term stability with a small standard deviation. The prominent advantages of high sensitivity, fast response, easy fabrication and compact size (total length of about 50 μm) imply that the proposed sensor has many potential applications for static or dynamic RH sensing.

1 September 2012 in Chinese Physics Letters
Verified
Journal Article
Closed access
PDF file
BXBen Xu
Ben Xu
YLYi Li
Yi Li
XDXinyong Dong
Xinyong Dong
SJShang-Zhong Jin
Shang-Zhong Jin
ZZZai-Xuan Zhang
Zai-Xuan Zhang
A refractive index (RI) sensor based on a cladding-etched thin-core single-mode fiber (TCSMF) sandwiched between two single-mode fibers is demonstrated. The experimental results show that the sensitivity, within the RI range of 1.333–1.340, is enhanced at least 6 times by etching. It increases with the surrounding RI and reaches 857.5 nm/RIU at RI of 1.3684, and it can be expected to be higher with the decrease of the cladding diameter of the TCSMF.

8 December 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
BXBen Xu
Ben Xu
YGYun Guo
Yun Guo
XMXingchao Ma
Xingchao Ma
YZYingfang Zhang
Yingfang Zhang
CZChunliu Zhao
Chunliu Zhao
DWDongning Wang
Dongning Wang
A tip Michelson interferometer (MI) is proposed and experimentally demonstrated for relative humidity (RH) sensing. The device consists of a short capillary tube with a small inner-diameter that is spliced to a single-mode fiber (SMF) and coated with agarose gel on its end-face, and the solid capillary wall and gel act as the sensing arm of the MI. When the agarose gel absorbs water modules, its refractive index and volume vary, resulting in the shift of the reflection spectrum of the MI. The relationship between the structural parameters and the performance of the device is revealed after performing theoretical analysis and experimental verification, which provides guidance for optimizing the device. The maximum sensitivity of 0.752 nm/% RH with a linear correlation coefficient of (Adj. R 2 ) 0.9927 within the range of 25-90% RH is obtained. Moreover, the proposed sensor exhibits good performances of robustness, compact size, high repeatability, fast response (<100 ms), and small measurement uncertainty (<0.21% RH), which makes the sensor promising for accurately static or dynamic moisture measuring.

22 May 2019 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
HZHua Zhang
Hua Zhang
DWDongning Wang
Dongning Wang
ZWZ. K. Wang
Z. K. Wang
BXBen Xu
Ben Xu
CZC. L. Zhao
C. L. Zhao
JLJianqing Li
Jianqing Li
A Mach-Zehnder interferometer constructed by femtosecond-laser written in-fiber waveguides in no-core fiber is demonstrated. Such an interferometer device consists of a section of no-core fiber in which a waveguide has been inscribed, fusion spliced with single mode fiber at its two ends. One of the interferometer arms is formed by the waveguide inscribed and the other follows the diverging light path inside the no-core fiber before arriving at the end of single mode fiber core. Such an internal structure based device can be used not only for strain sensing and external refractive index measurement.

28 December 2021 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
JYJing Yan
Jing Yan
DWDongning Wang
Dongning Wang
YGYunpeng Ge
Yunpeng Ge
YGYun Guo
Yun Guo
BXBen Xu
Ben Xu
A whispering-gallery-mode (WGM) resonator with an L-shaped microcavity for humidity sensing is proposed and demonstrated. The L-shaped microcavity is fabricated by using femtosecond laser micromachining, fusion discharge and chemical etching methods. By placing two microspheres in the microcavity, of which one is used as the whispering gallery mode resonant cavity, and the other plays the role of changing the optical path to help activating whispering gallery mode resonance. The device has a linear response to humidity with the linearity of 99.1% and the sensitivity of −0.23 dB/%RH, within the relative humidity range of 30%–70%, under the room temperature of 25 °C. The response time for the humidity increasing is as short as 240 ms, and the recovery time is 453 ms. The device is simple in fabrication, robust and has good operation stability.