A fall of an elderly person often leads to serious injuries or even death. Many falls occur in the home environment and remain unrecognized. Therefore, a reliable fall detection is absolutely necessary for a fast help. Wrist-worn accelerometer based fall detection systems are developed, but the accuracy and precision are not standardized, comparable, or sometimes even known. In this work, we present an overview about existing public databases with sensor based fall datasets and harmonize existing wrist-worn datasets for a broader and robust evaluation. Furthermore, we are analyzing the current possible recognition rate of fall detection using deep learning algorithms for mobile and embedded systems. The presented results and databases can be used for further research and optimizations in order to increase the recognition rate to enhance the independent life of the elderly. Furthermore, we give an outlook for a convenient application and wrist device.
Background: Assistive technologies can help people living with dementia maintain their everyday activities. Nevertheless, there is a gap between the potential and use of these materials. Involving future users may help close this gap, but the impact on people with dementia is unclear. Objective: We aimed to determine if user-centered development of smartwatch-based interventions together with people with dementia is feasible. In addition, we evaluated the extent to which user feedback is plausible and therefore helpful for technological improvements. Methods: We examined the interactions between smartwatches and people with dementia or people with mild cognitive impairment. All participants were prompted to complete 2 tasks (drinking water and a specific cognitive task). Prompts were triggered using a smartphone as a remote control and were repeated up to 3 times if participants failed to complete a task. Overall, 50% (20/40) of the participants received regular prompts, and 50% (20/40) received intensive audiovisual prompts to perform everyday tasks. Participants’ reactions were observed remotely via cameras. User feedback was captured via questionnaires, which included topics like usability, design, usefulness, and concerns. The internal consistency of the subscales was calculated. Plausibility was also checked using qualitative approaches. Results: Participants noted their preferences for particular functions and improvements. Patients struggled with rating using the Likert scale; therefore, we assisted them with completing the questionnaire. Usability (mean 78 out of 100, SD 15.22) and usefulness (mean 9 out of 12) were rated high. The smartwatch design was appealing to most participants (31/40, 76%). Only a few participants (6/40, 15%) were concerned about using the watch. Better usability was associated with better cognition. The observed success and self-rated task comprehension were in agreement for most participants (32/40, 80%). In different qualitative analyses, participants’ responses were, in most cases, plausible. Only 8% (3/40) of the participants were completely unaware of their irregular task performance. Conclusions: People with dementia can have positive experiences with smartwatches. Most people with dementia provided valuable information. Developing assistive technologies together with people with dementia can help to prioritize the future development of functional and nonfunctional features.
Working in front of the computer for long periods of time leads to exhaustion, fatigue and high strain on the eyes. Often the natural eye blink activity is disturbed and the eyes do not form enough tears to stay moist. Computer workstations are usually equipped with a webcam, making it convenient to monitor eye blinking and easy to perform blink interventions. In this paper, we present a blink detection method that uses 3D landmarks. After presenting existing publicly available blink databases, we evaluate the accuracy of our blink detection method and discuss the results. In addition, we illustrate the scope of our eye blink detection method in the application of a non-contact stress detection software to support stress reduction in the field of occupational health management.
1 January 2020 in Journal of Rehabilitation and Assistive Technologies Engineering
Introduction: Falls cause major expenses in the healthcare sector. We investigate the ability of supporting a fall risk assessment by introducing algorithms for automated assessments of standardized fall risk-related tests via wearable devices. Methods: In a study, 13 participants conducted the standardized 6-Minutes Walk Test, the Timed-Up-and-Go Test, the 30-Second Sit-to-Stand Test, and the 4-Stage Balance Test repeatedly, producing 226 tests in total. Automated algorithms computed by wearable devices, as well as a visual analysis of the recorded data streams, were compared to the observational results conducted by physiotherapists. Results: There was a high congruence between automated assessments and the ground truth for all four test types (ranging from 78.15% to 96.55%), with deviations ranging all well within one standard deviation of the ground truth. Fall risk (assessed by questionnaire) correlated with the individual tests. Conclusions: The automated fall risk assessment using wearable devices and algorithms matches the validity of the ground truth, thus providing a resourceful alternative to the effortful observational assessment, while minimizing the risk of human error. No single test can predict overall fall risk; instead, a much more complex model with additional input parameters (e.g., fall history, medication etc.) is needed.
In Holter monitoring, the precise detection of standard heartbeats and ventricular premature contractions (PVCs) is paramount for accurate cardiac rhythm assessment. This study introduces a novel application of the 1D U-Net neural network architecture with the aim of enhancing PVC detection in Holter recordings. Training data comprised the Icentia 11k and INCART DB datasets, as well as our custom dataset. The model’s efficacy was subsequently validated against traditional Holter analysis methodologies across multiple databases, including AHA DB, MIT 11 DB, and NST, as well as another custom dataset that was specifically compiled by the authors encompassing challenging real-world examples. The results underscore the 1D U-Net model’s prowess in QRS complex detection, achieving near-perfect balanced accuracy scores across all databases. PVC detection exhibited variability, with balanced accuracy scores ranging from 0.909 to 0.986. Despite some databases, like the AHA DB, showcasing lower sensitivity metrics, their robust, balanced accuracy accentuates the model’s equitable performance in discerning both false positives and false negatives. In conclusion, while the 1D U-Net architecture is a formidable tool for QRS detection, there’s a clear avenue for further refinement in its PVC detection capability, given the inherent complexities and noise challenges in real-world PVC occurrences.