Stefan Stübinger

Dr. Stefan Stübinger


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2012 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
MPMichael Plecko
Michael Plecko
CSChristine Sievert
Christine Sievert
DADaniel Andermatt
Daniel Andermatt
RFRobert Frigg
Robert Frigg
PKPeter WM Kronen
Peter WM Kronen
BRBrigitte von Rechenberg
Brigitte von Rechenberg
Background: In the present study, 4 different metallic implant materials, either partly coated or polished, were tested for their osseointegration and biocompatibility in a pelvic implantation model in sheep.Methods: Materials to be evaluated were: Cobalt-Chrome (CC), Cobalt-Chrome/Titanium coating (CCTC), Cobalt-Chrome/Zirconium/Titanium coating (CCZTC), Pure Titanium Standard (PTST), Steel, TAN Standard (TANST) and TAN new finish (TANNEW). Surgery was performed on 7 sheep, with 18 implants per sheep, for a total of 63 implants. After 8 weeks, the specimens were harvested and evaluated macroscopically, radiologically, biomechanically (removal torque), histomorphometrically and histologically.Results: Cobalt-Chrome screws showed significantly (p = 0.031) lower removal torque values than pure titanium screws and also a tendency towards lower values compared to the other materials, except for steel. Steel screws showed no significant differences, in comparison to cobalt-chrome and TANST, however also a trend towards lower torque values than the remaining materials. The results of the fluorescence sections agreed with those of the biomechanical test. Histomorphometrically, there were no significant differences of bone area between the groups. The BIC (bone-to-implant-contact), used for the assessment of the osseointegration, was significantly lower for cobalt-chrome, compared to steel (p = 0.001). Steel again showed a lower ratio (p = 0.0001) compared to the other materials.Conclusion: This study demonstrated that cobalt-chrome and steel show less osseointegration than the other metals and metal-alloys. However, osseointegration of cobalt-chrome was improved by zirconium and/or titanium based coatings (CCTC, TANST, TAN, TANNEW) being similar as pure titanium in their osseointegrative behavior.

1 June 2010 in Clinical, Cosmetic and Investigational Dentistry
Verified
Journal Article
Open access
PDF file
SSStefan Stübinger
Stefan Stübinger
Advances in bone surgery: the Er:YAG laser in oral surgery and implant dentistry Stefan StübingerCompetence Center for Applied Biotechnology and Molecular Medicine, University of Zürich, Zürich, Switzerland The erbium-doped yttrium aluminium garnet (Er:YAG) laser has emerged as a possible alternative to conventional methods of bone ablation because of its wavelength of 2.94 μm, which coincides with the absorption peak of water. Over the last decades in several experimental and clinical studies, the widespread initial assumption that light amplification for stimulated emission of radiation (laser) osteotomy inevitably provokes profound tissue damage and delayed wound healing has been refuted. In addition, the supposed disadvantage of prolonged osteotomy times could be overcome by modern short-pulsed Er:YAG laser systems. Currently, the limiting factors for a routine application of lasers for bone ablation are mainly technical drawbacks such as missing depth control and a difficult and safe guidance of the laser beam. This article gives a short overview of the development process and current possibilities of noncontact Er:YAG laser osteotomy in oral and implant surgery.Keywords: carbonization, laser osteotomy, ablation, dental implants

6 April 2013 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
SSStefan Stübinger
Stefan Stübinger
IMIsabel Mosch
Isabel Mosch
PRPierfrancesco Robotti
Pierfrancesco Robotti
MSMichéle Sidler
Michéle Sidler
KKKarina Klein
Karina Klein
BRBrigitte von Rechenberg
Brigitte von Rechenberg

25 August 2010 in Lasers in Surgery and Medicine
Verified
Journal Article
Closed access
PDF file
SSStefan Stübinger
Stefan Stübinger
KBKristina Biermeier
Kristina Biermeier
BBBeatus Bächi
Beatus Bächi
SFStephen J. Ferguson
Stephen J. Ferguson
RSRobert Sader
Robert Sader
BRBrigitte von Rechenberg
Brigitte von Rechenberg

29 September 2010 in Lasers in Surgery and Medicine
Verified
Journal Article
Closed access
PDF file
SSStefan Stübinger
Stefan Stübinger
KNKatja Nuss
Katja Nuss
MPMichaela Pongratz
Michaela Pongratz
JPJill Price
Jill Price
RSRobert Sader
Robert Sader
BRBrigitte von Rechenberg
Brigitte von Rechenberg

11 June 2015 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
SSStefan Stübinger
Stefan Stübinger
ADAnika Drechsler
Anika Drechsler
ABAlexander Bürki
Alexander Bürki
KKKarina Klein
Karina Klein
PKPeter Kronen
Peter Kronen
BRBrigitte von Rechenberg
Brigitte von Rechenberg