Ana Messias

Prof. Ana Messias

University of Coimbra, Centre for Mechanical Engineering, Materials and Processes (CEMMPRE), Department of Mechanical Engineering
+1
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016 in Journal of Endodontics
Verified
Journal Article
Closed access
Ramos Joao CarlosRamos Joao Carlos
Ramos Joao Carlos
Paulo J. PalmaPaulo J. Palma
Paulo J. Palma
RNRita Nascimento
Rita Nascimento
FCFrancisco Caramelo
Francisco Caramelo
Ana MessiasAna Messias
Ana Messias
João Miguel Marques dos SantosJoão Miguel Marques dos Santos
João Miguel Marques dos Santos

22 November 2018 in Clinical Oral Implants Research
Verified
Journal Article
Open access
PDF file
Ana MessiasAna Messias
Ana Messias
Pedro M.G. NicolauPedro M.G. Nicolau
Pedro M.G. Nicolau
FGFernando Guerra
Fernando Guerra
Aim: The aim of this study was to compare clinical and radiographic outcomes of dental implants with different neck characteristics.Methods: A protocol‐oriented search aimed at the question: “In patients subjected to tooth replacement with screw‐type dental implants does the modification of the implant neck macro‐ or microgeometry contribute to the improvement of survival rates and maintenance of the peri‐implant marginal bone levels?” Primary outcomes were survival and marginal bone level (MBL) changes evaluated on randomized controlled trials with >10 participants and follow‐up >1 year. Risk of bias was evaluated using the Cochrane Collaboration's tool. The review follows the PRISMA statement.Results: Forty‐three studies compared: (a) One‐ versus two‐piece implants (N = 7); (b) Two‐piece implants with different neck characteristics (machined and rough collars, microthreads, LASER microtexturing) (N = 21); (c) Two‐piece implants with macrogeometry modifications (tapering, back‐tapering, and scalloping) (N = 6). One‐ and two‐piece implants showed similar survival (RR = 0.45, 95% CI: [0.12, 1.66], p = 0.23) and MBL changes (WMD = 0.09 mm, 95% CI: [−0.27, 0.45], p = 0.64) at 1‐year post‐loading. Machined collar implants have higher risk of early failure than rough collar implants (RR = 3.96, 95% CI: [1.12, 13.93], p = 0.03) and 0.43 mm higher bone resorption (95% CI: [0.0, 0.86], p = 0.05). Microthreads (WMD = 0.07 mm, 95% CI: [−0.01, 0.15], p = 0.10) and LASER microtexturing (WMD = 0.15 mm, 95% CI: [−0.35, 0.65], p = 0.56) do not reduce bone resorption. Scalloped implants have 1.26 mm higher resorption (95% CI: [0.72, 2.00], p < 0.001).Conclusions: One‐ and two‐piece implants have similar survival and MBL changes. Rough collar implants have lower MBL changes than machined collar implants. Additional modifications to rough collars are irrelevant.

12 November 2021 in Medicina
Verified
Journal Article
Open access
PDF file
Alexandra VinagreAlexandra Vinagre
Alexandra Vinagre
CCCatarina Castanheira
Catarina Castanheira
Ana MessiasAna Messias
Ana Messias
Paulo J. PalmaPaulo J. Palma
Paulo J. Palma
Ramos Joao CarlosRamos Joao Carlos
Ramos Joao Carlos
Background and Objectives: This systematic review aimed to assess the literature focusing on the clinical management of traumatized teeth with Pulp Canal Obliteration (PCO) and propose an updated clinical decision-making algorithm. The present review follows the PRISMA guidelines and was registered on PROSPERO database (CRD42020200656). Materials and Methods: An electronic search strategy was performed in Pubmed, EBSCOhost and LILACS from inception to March 2021. Only anterior permanent teeth with PCO due to dental trauma were included. Regarding clinical approaches, only teeth managed with a “watchful waiting” approach, tooth bleaching or root canal treatment (RCT) were included. Quality assessment was performed using the JBI Critical Appraisal Tool for Case Reports. Results: Twenty case reports were selected, resulting in a total of 27 patients. The number of traumatized teeth diagnosed with PCO was 33. The “watchful waiting” approach was the most implemented clinical strategy. Discolored non-symptomatic PCO teeth were mostly managed with external bleaching. The prevalence of pulp necrosis (PN) was 36.4%. For teeth diagnosed with PN, non-surgical RCT was performed in 10 teeth and surgical RCT in one tooth. Guided endodontic technique was performed in six of those teeth. Conclusions: For discolored non-symptomatic PCO teeth, external bleaching is advocated and the RCT approach should not be implemented as a preventive intervention strategy. Symptomatic PCO teeth should follow regular endodontic treatment pathways. Clinical approach of teeth with PCO should follow a decision-making algorithm incorporating clinical and radiographic signs and patient-reported symptoms.

12 December 2018 in Odontology
Verified
Journal Article
Closed access
PDF file
Paulo J. PalmaPaulo J. Palma
Paulo J. Palma
Ana MessiasAna Messias
Ana Messias
ACAntónio Rosa Cerqueira
António Rosa Cerqueira
LTLuís Diogo Tavares
Luís Diogo Tavares
FCFrancisco Caramelo
Francisco Caramelo
João Miguel Marques dos SantosJoão Miguel Marques dos Santos
João Miguel Marques dos Santos

3 July 2020 in Polymers
Verified
Journal Article
Open access
PDF file
ASAna M. Sousa
Ana M. Sousa
Ana Catarina PinhoAna Catarina Pinho
Ana Catarina Pinho
Ana MessiasAna Messias
Ana Messias
Ana Paula PiedadeAna Paula Piedade
Ana Paula Piedade
Athletes from contact sports are more prone to orofacial injuries because of the exposure to possible shocks and collisions derived from physical proximity. The use of protector polymeric mouthguards proved to be useful in the prevention of the described injuries. There are different types of mouthguards with varying ranges of protection and prices, but they are all made from polymers and share the same propose: to absorb and dissipate the impact energy resulting from the shocks. As they are used inside the mouth, they should not impair breathing and speaking nor compromise the comfort of the athlete. However, the ideal mouthguard is yet to be created. The choice of the most appropriate polymeric material and the standard required properties have not yet been reported. Regardless of the numerous studies in this field, normalized control parameters for both material characterization and mouthguard fabrication are absent. This paper aims to present a review of the current types of available mouthguards and their properties/characteristics. Moreover, a detailed description of the most common polymers for the fabrication of mouthguards, together with the manufacturing techniques, are discussed.

30 March 2016 in Journal of Clinical Periodontology
Verified
Journal Article
Open access
PDF file
SRSalomão Rocha
Salomão Rocha
WWWilfried Wagner
Wilfried Wagner
JWJörg Wiltfang
Jörg Wiltfang
Pedro M.G. NicolauPedro M.G. Nicolau
Pedro M.G. Nicolau
MMMaximilian Moergel
Maximilian Moergel
FGFernando Guerra
Fernando Guerra
Objective: Evaluation of differences in the clinical performance and crestal bone levels between implants restored with single crowns with platform‐matched or platform‐switched abutments after 3 years.Material and Methods: The study enrolled adult patients missing two or more adjacent teeth in the posterior mandible with natural teeth mesial to the implant site. Randomization followed open‐flap implant insertion and the corresponding matching or switching healing abutments placed at surgery. Conventional loading was made with cemented crowns. Clinical follow‐up took place annually after loading up to 3 years. Bone level changes were measured in standardized radiographs as the variation in crestal bone from one evaluation to the next.Results: Sixty‐three patients with a total of 135 implants (66 platform matching, 69 platform switching) were analysed. From surgery to 36 months, mean bone loss was 0.28 ± 0.56 mm for the platform‐switching group and 0.68 ± 0.64 mm for the platform‐matching group. A statistically significant difference was found between groups (p = 0.002) with an estimate of 0.39 mm (0.15–0.64, 95% CI) in favour of platform switching.Conclusions: After 3 years, platform‐switching restorations showed a significant effect in the preservation of marginal bone levels compared to platform‐matching restorations.