Younghoon Cho

Dr. Younghoon Cho


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2023 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
TLTaeyoung Lee
Taeyoung Lee
YCYounghoon Cho
Younghoon Cho
KCKwang Su Cha
Kwang Su Cha
JJJinhwan Jung
Jinhwan Jung
JCJungim Cho
Jungim Cho
JKJeong-Whun Kim
Jeong-Whun Kim
Background: Consumer sleep trackers (CSTs) have gained significant popularity because they enable individuals to conveniently monitor and analyze their sleep. However, limited studies have comprehensively validated the performance of widely used CSTs. Our study therefore investigated popular CSTs based on various biosignals and algorithms by assessing the agreement with polysomnography. Objective: This study aimed to validate the accuracy of various types of CSTs through a comparison with in-lab polysomnography. Additionally, by including widely used CSTs and conducting a multicenter study with a large sample size, this study seeks to provide comprehensive insights into the performance and applicability of these CSTs for sleep monitoring in a hospital environment. Methods: The study analyzed 11 commercially available CSTs, including 5 wearables (Google Pixel Watch, Galaxy Watch 5, Fitbit Sense 2, Apple Watch 8, and Oura Ring 3), 3 nearables (Withings Sleep Tracking Mat, Google Nest Hub 2, and Amazon Halo Rise), and 3 airables (SleepRoutine, SleepScore, and Pillow). The 11 CSTs were divided into 2 groups, ensuring maximum inclusion while avoiding interference between the CSTs within each group. Each group (comprising 8 CSTs) was also compared via polysomnography. Results: The study enrolled 75 participants from a tertiary hospital and a primary sleep-specialized clinic in Korea. Across the 2 centers, we collected a total of 3890 hours of sleep sessions based on 11 CSTs, along with 543 hours of polysomnography recordings. Each CST sleep recording covered an average of 353 hours. We analyzed a total of 349,114 epochs from the 11 CSTs compared with polysomnography, where epoch-by-epoch agreement in sleep stage classification showed substantial performance variation. More specifically, the highest macro F1 score was 0.69, while the lowest macro F1 score was 0.26. Various sleep trackers exhibited diverse performances across sleep stages, with SleepRoutine excelling in the wake and rapid eye movement stages, and wearables like Google Pixel Watch and Fitbit Sense 2 showing superiority in the deep stage. There was a distinct trend in sleep measure estimation according to the type of device. Wearables showed high proportional bias in sleep efficiency, while nearables exhibited high proportional bias in sleep latency. Subgroup analyses of sleep trackers revealed variations in macro F1 scores based on factors, such as BMI, sleep efficiency, and apnea-hypopnea index, while the differences between male and female subgroups were minimal. Conclusions: Our study showed that among the 11 CSTs examined, specific CSTs showed substantial agreement with polysomnography, indicating their potential application in sleep monitoring, while other CSTs were partially consistent with polysomnography. This study offers insights into the strengths of CSTs within the 3 different classes for individuals interested in wellness who wish to understand and proactively manage their own sleep.

1 July 2020 in The Lancet Digital Health
Verified
Journal Article
Open access
JKJoon-Myoung Kwon
Joon-Myoung Kwon
YCYounghoon Cho
Younghoon Cho
KJKi-Hyun Jeon
Ki-Hyun Jeon
SCSoohyun Cho
Soohyun Cho
KKKyung-Hee Kim
Kyung-Hee Kim
BOByung-Hee Oh
Byung-Hee Oh
Anaemia is an important health-care burden globally, and screening for anaemia is crucial to prevent multi-organ injury, irreversible complications, and life-threatening adverse events. We aimed to establish whether a deep learning algorithm (DLA) that enables non-invasive anaemia screening from electrocardiograms (ECGs) might improve the detection of anaemia. We did a retrospective, multicentre, diagnostic study in which a DLA was developed using ECGs and then internally and externally validated. We used data from two hospitals, Sejong General Hospital (hospital A) and Mediplex Sejong Hospital (hospital B), in South Korea. Data from hospital A was for DLA development and internal validation, and data from hospital B was for external validation. We included individuals who had at least one ECG with a haemoglobin measurement within 1 h of the index ECG and excluded individuals with missing demographic, electrocardiographic, or haemoglobin information. Three types of DLA were developed with 12-lead, 6-lead (limb lead), and single-lead (lead I) ECGs to detect haemoglobin concentrations of 10 g/dL or less. The DLA was built by a convolutional neural network and used 500-Hz raw ECG, age, and sex as input data. The study period ran from Oct 1, 2016, to Sept 30, 2019, in hospital A and March 1, 2017, to Sept 30, 2019, in hospital B. 40 513 patients at hospital A and 4737 patients at hospital B were eligible for inclusion. We excluded 281 patients at hospital A and 72 patients at hospital B because of missing values for clinical information and ECG data. The development dataset comprised 57 435 ECGs from 31 898 patients, and the algorithm was internally validated with 7974 ECGs from 7974 patients. The external validation dataset included 4665 ECGs from 4665 patients. 586 (internal) and 194 (external) patients within the combined dataset were found to be anaemic. During internal and external validation, the area under the receiver operating characteristics curve (AUROC) of the DLA using a 12-lead ECG for detecting anaemia was 0·923 for internal validation and 0·901 for external validation. Using a 90% sensitivity operating point for the development data, the sensitivity, specificity, negative predictive value, and positive predictive value of internal validation were 89·8%, 81·5%, 99·4%, and 20·0%, respectively, and those of external validation were 86·1%, 76·2%, 99·2%, and 13·5%, respectively. The DLA focused on the QRS complex for deciding the presence of anaemia in a sensitivity map. The AUROCs of DLAs using 6 leads and a single lead were in the range of 0·841-0·890. In this study, using raw ECG data, a DLA accurately detected anaemia. The application of artificial intelligence to ECGs could enable screening for anaemia. None.

1 September 2019 in British Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
YCY.S. Chung
Y.S. Chung
YCYounghoon Cho
Younghoon Cho
BKBo Hae Kim
Bo Hae Kim

1 January 2018 in Allergy, Asthma & Immunology Research
Verified
Journal Article
Open access
PDF file
DKDong-Kyu Kim
Dong-Kyu Kim
SKSeong Il Kang
Seong Il Kang
IKIl Gyu Kong
Il Gyu Kong
YCYounghoon Cho
Younghoon Cho
SSSeul Ki Song
Seul Ki Song
DKDae Woo Kim
Dae Woo Kim
Kim DK, et al. Allergy Asthma Immunol Res. 2018 Sep;10(5):490-502. https://doi.org/10.4168/aair.2018.10.5.490

24 September 2019 in Toxins
Verified
Journal Article
Open access
PDF file
YCYounghoon Cho
Younghoon Cho
Ji-Hyun LeeJi-Hyun Lee
Ji-Hyun Lee
KLKang-Woo Lee
Kang-Woo Lee
Kyu-Lim LeeKyu-Lim Lee
Kyu-Lim Lee
Jae Seung KangJae Seung Kang
Jae Seung Kang
Hee-Jin KimHee-Jin Kim
Hee-Jin Kim
Botulinum neurotoxin (BoNT) injections are widely used for facial rejuvenation procedures, and the procerus muscle is a major target in cases of glabellar transverse lines or rhytids. Although there have been many cadaveric studies of the procerus, its depth and thickness have not been investigated thoroughly. The aim of this study was to measure the depth and thickness of the procerus and identify the location of the intercanthal vein using ultrasonographic (US) imaging and the three-dimensional scanning method, which is needed to know to avoid side effects during BoNT injections. The morphology of the procerus was classified into two types based on the US images obtained at the glabella. The procerus was located deeper below the skin surface at the glabella than the sellion (3.8 ± 0.7 mm versus 2.7 ± 0.6 mm). The width of the procerus in US images increased from the sellion (10.9 ± 0.2 mm) to the glabella (14.5 ± 4.6 mm), whereas its thickness decreased (from 1.6 ± 0.6 mm to 1.1 ± 0.5 mm). The intercanthal vein was located 5.1 ± 4.0 mm superior to the sellion and 3.0 ± 0.6 mm below the skin’s surface. The present findings provide anatomical knowledge as well as the reference location information for use when injecting BoNT into the procerus.

4 March 2014 in Clinical Anatomy
Verified
Journal Article
Closed access
PDF file
SWSung‐Yoon Won
Sung‐Yoon Won
YCYounghoon Cho
Younghoon Cho
YCYou-Jin Choi
You-Jin Choi
VFVittorio Favero
Vittorio Favero
HWHee‐Soon Woo
Hee‐Soon Woo
Hee-Jin KimHee-Jin Kim
Hee-Jin Kim