The study and optimization of epoxy-based negative photoresist (SU-8) microstructures through a low-cost process and without the need for cleanroom facility is presented in this paper. It is demonstrated that the Ultraviolet Rays (UV) exposure equipment, commonly used in the Printed Circuit Board (PCB) industry, can replace the more expensive and less available equipment, as the Mask Aligner that has been used in the last 15 years for SU-8 patterning. Moreover, high transparency masks, printed in a photomask, are used, instead of expensive chromium masks. The fabrication of well-defined SU-8 microstructures with aspect ratios more than 20 is successfully demonstrated with those facilities. The viability of using the gray-scale technology in the photomasks for the fabrication of 3D microstructures is also reported. Moreover, SU-8 microstructures for different applications are shown throughout the paper.
By combining biomaterials, cell culture, and microfluidic technology, organ-on-a-chip (OoC) platforms have the ability to reproduce the physiological microenvironment of human organs. For this reason, these advanced microfluidic devices have been used to resemble various diseases and investigate novel treatments. In addition to the experimental assessment, numerical studies of biodevices have been performed aiming at their improvement and optimization. Despite considerable progress in numerical modeling of biodevices, the validation of these computational models through comparison with experimental assays remains a significant gap in the current literature. This step is critical to ensure the accuracy and reliability of numerical models, and consequently enhance confidence in their predictive results. The aim of the present work is to develop a numerical model capable of reproducing the fluid flow behavior within an OoC, for future investigations, encompassing the geometry optimization. In this study, the validation of a numerical model for an OoC microfluidic device was undertaken. This comprised both quantitative and qualitative assessments of trace microparticles flowing through a physical OoC model. High-speed microscopy images of the flow, using a blood analog fluid, were analyzed and compared with the numerical simulations run using the Ansys Fluent software. For a qualitative analysis, the particles' paths through the inlet and bifurcations were observed whereas, for a quantitative analysis, the particle velocities were measured. Furthermore, oxygen transport was simulated and evaluated for different Reynolds numbers. In both qualitative and quantitative analyses, the results predicted by the numerical model and the ones outputted by the experimental model were in good agreement. These findings underscore the capability and potential of the developed numerical model. The examination of oxygen transport at various vertical positions within the organoid has revealed that for lower positions, oxygen transport predominantly occurs through diffusion, leading to a symmetric distribution of oxygen. Contrastingly, the convection phenomenon becomes more evident in the upper region of the organoid. The successful validation of the numerical model against experimental data shows its accuracy and reliability in simulating the fluid flow within the OoC, which consequently can expedite the OoC design process by reducing the need for prototypes' fabrication and costly laboratory experiments.
The advanced and widespread use of microfluidic devices, which are usually fabricated in polydimethylsiloxane (PDMS), requires the integration of many sensors, always compatible with microfluidic fabrication processes. Moreover, current limitations of the existing optical and electrochemical oxygen sensors regarding long-term stability due to sensor degradation, biofouling, fabrication processes and cost have led to the development of new approaches. Thus, this manuscript reports the development, fabrication and characterization of a low-cost and highly sensitive dissolved oxygen optical sensor based on a membrane of PDMS doped with platinum octaethylporphyrin (PtOEP) film, fabricated using standard microfluidic materials and processes. The excellent mechanical and chemical properties (high permeability to oxygen, anti-biofouling characteristics) of PDMS result in membranes with superior sensitivity compared with other matrix materials. The wide use of PtOEP in sensing applications, due to its advantage of being easily synthesized using microtechnologies, its strong phosphorescence at room temperature with a quantum yield close to 50%, its excellent Strokes Shift as well as its relatively long lifetime (75 µs), provide the suitable conditions for the development of a miniaturized luminescence optical oxygen sensor allowing long-term applications. The influence of the PDMS film thickness (0.1–2.5 mm) and the PtOEP concentration (363, 545, 727 ppm) in luminescent properties are presented. This enables to achieve low detection levels in a gas media range from 0.5% up to 20%, and in liquid media from 0.5 mg/L up to 3.3 mg/L at 1 atm, 25 °C. As a result, we propose a simple and cost-effective system based on a LED membrane photodiode system to detect low oxygen concentrations for in situ applications.
1 June 2016 in Journal of Polymer Science Part B: Polymer Physics