Vânia Pinto

Dr. Vânia Pinto

Center for Microelectromechanical Systems; University of Minho; 4800-058 Guimaraes, Portugal
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2014 in Micromachines
Verified
Journal Article
Open access
PDF file
Vânia PintoVânia Pinto
Vânia Pinto
Paulo SousaPaulo Sousa
Paulo Sousa
Vanessa CardosoVanessa Cardoso
Vanessa Cardoso
Graca MinasGraca Minas
Graca Minas
The study and optimization of epoxy-based negative photoresist (SU-8) microstructures through a low-cost process and without the need for cleanroom facility is presented in this paper. It is demonstrated that the Ultraviolet Rays (UV) exposure equipment, commonly used in the Printed Circuit Board (PCB) industry, can replace the more expensive and less available equipment, as the Mask Aligner that has been used in the last 15 years for SU-8 patterning. Moreover, high transparency masks, printed in a photomask, are used, instead of expensive chromium masks. The fabrication of well-defined SU-8 microstructures with aspect ratios more than 20 is successfully demonstrated with those facilities. The viability of using the gray-scale technology in the photomasks for the fabrication of 3D microstructures is also reported. Moreover, SU-8 microstructures for different applications are shown throughout the paper.

1 April 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Vânia PintoVânia Pinto
Vânia Pinto
Paulo SousaPaulo Sousa
Paulo Sousa
Susana O. CatarinoSusana O. Catarino
Susana O. Catarino
MCMargarida Correia-Neves
Margarida Correia-Neves
Graca MinasGraca Minas
Graca Minas

28 October 2023 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
Violeta CarvalhoVioleta Carvalho
Violeta Carvalho
IGInês Maia Gonçalves
Inês Maia Gonçalves
NRNelson Rodrigues
Nelson Rodrigues
Paulo SousaPaulo Sousa
Paulo Sousa
Vânia PintoVânia Pinto
Vânia Pinto
Rui A. LimaRui A. Lima
Rui A. Lima
By combining biomaterials, cell culture, and microfluidic technology, organ-on-a-chip (OoC) platforms have the ability to reproduce the physiological microenvironment of human organs. For this reason, these advanced microfluidic devices have been used to resemble various diseases and investigate novel treatments. In addition to the experimental assessment, numerical studies of biodevices have been performed aiming at their improvement and optimization. Despite considerable progress in numerical modeling of biodevices, the validation of these computational models through comparison with experimental assays remains a significant gap in the current literature. This step is critical to ensure the accuracy and reliability of numerical models, and consequently enhance confidence in their predictive results. The aim of the present work is to develop a numerical model capable of reproducing the fluid flow behavior within an OoC, for future investigations, encompassing the geometry optimization. In this study, the validation of a numerical model for an OoC microfluidic device was undertaken. This comprised both quantitative and qualitative assessments of trace microparticles flowing through a physical OoC model. High-speed microscopy images of the flow, using a blood analog fluid, were analyzed and compared with the numerical simulations run using the Ansys Fluent software. For a qualitative analysis, the particles' paths through the inlet and bifurcations were observed whereas, for a quantitative analysis, the particle velocities were measured. Furthermore, oxygen transport was simulated and evaluated for different Reynolds numbers. In both qualitative and quantitative analyses, the results predicted by the numerical model and the ones outputted by the experimental model were in good agreement. These findings underscore the capability and potential of the developed numerical model. The examination of oxygen transport at various vertical positions within the organoid has revealed that for lower positions, oxygen transport predominantly occurs through diffusion, leading to a symmetric distribution of oxygen. Contrastingly, the convection phenomenon becomes more evident in the upper region of the organoid. The successful validation of the numerical model against experimental data shows its accuracy and reliability in simulating the fluid flow within the OoC, which consequently can expedite the OoC design process by reducing the need for prototypes' fabrication and costly laboratory experiments.

1 July 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Vânia PintoVânia Pinto
Vânia Pinto
CAC.F. Araújo
C.F. Araújo
Paulo SousaPaulo Sousa
Paulo Sousa
LGL.M. Gonçalves
L.M. Gonçalves
Graca MinasGraca Minas
Graca Minas

21 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Camila PensoCamila Penso
Camila Penso
JRJoão L. Rocha
João L. Rocha
Marcos MartinsMarcos Martins
Marcos Martins
Paulo SousaPaulo Sousa
Paulo Sousa
Vânia PintoVânia Pinto
Vânia Pinto
Luís Miguel GoncalvesLuís Miguel Goncalves
Luís Miguel Goncalves
The advanced and widespread use of microfluidic devices, which are usually fabricated in polydimethylsiloxane (PDMS), requires the integration of many sensors, always compatible with microfluidic fabrication processes. Moreover, current limitations of the existing optical and electrochemical oxygen sensors regarding long-term stability due to sensor degradation, biofouling, fabrication processes and cost have led to the development of new approaches. Thus, this manuscript reports the development, fabrication and characterization of a low-cost and highly sensitive dissolved oxygen optical sensor based on a membrane of PDMS doped with platinum octaethylporphyrin (PtOEP) film, fabricated using standard microfluidic materials and processes. The excellent mechanical and chemical properties (high permeability to oxygen, anti-biofouling characteristics) of PDMS result in membranes with superior sensitivity compared with other matrix materials. The wide use of PtOEP in sensing applications, due to its advantage of being easily synthesized using microtechnologies, its strong phosphorescence at room temperature with a quantum yield close to 50%, its excellent Strokes Shift as well as its relatively long lifetime (75 µs), provide the suitable conditions for the development of a miniaturized luminescence optical oxygen sensor allowing long-term applications. The influence of the PDMS film thickness (0.1–2.5 mm) and the PtOEP concentration (363, 545, 727 ppm) in luminescent properties are presented. This enables to achieve low detection levels in a gas media range from 0.5% up to 20%, and in liquid media from 0.5 mg/L up to 3.3 mg/L at 1 atm, 25 °C. As a result, we propose a simple and cost-effective system based on a LED membrane photodiode system to detect low oxygen concentrations for in situ applications.

1 June 2016 in Journal of Polymer Science Part B: Polymer Physics
Verified
Journal Article
Closed access
PDF file
Vanessa CardosoVanessa Cardoso
Vanessa Cardoso
AMAna Machado
Ana Machado
Vânia PintoVânia Pinto
Vânia Pinto
Paulo SousaPaulo Sousa
Paulo Sousa
GBGabriela Botelho
Gabriela Botelho
Senentxu Lanceros-MendezSenentxu Lanceros-Mendez
Senentxu Lanceros-Mendez