An experimental investigation of PVC-concrete columns is presented to assess the efficiency of using PVC tube for enhancing strength and ductility of PVC-concrete columns. Study was conducted to assess provided PVC casing confinement mechanism efficiency for enhancing strength and ductility of considered PVC- concrete columns. To investigate the composite mechanism and confining mechanism of the PVC tube, fabricated specimens are tested under uniaxial compression loading in two modes of load application; composite mode and confining mode. The results showed that the composite mode columns exhibit more strength improving than those of confining mode. The upgrading rate in sustained loading resistance of composite mode columns varied from 2.25 to 1.56, while it was 2.07 to 1.55 for confining mode columns. The same comparison is entirely reversed in scope of ductility, where confining mode columns exhibited more axial and lateral deformations than the corresponding composite mode columns. The results are normalized in term of radial stress (fr) and concrete compressive strength (f’e), determined enhanced confined concrete strength (f’ee) could be used to predicate plastic capacity of columns of different mechanism.
For reinforced concrete beams, the shear failure mode is confirmed to occur in disturbed regions rather than in the Bernoulli region where stresses can be computed from the flexure formula. Thus, the provision of such regions with shear deficiencies is of great importance. In this study, a tension field system is suggested to embrace the inevitable concrete compression field originating within disturbed regions. Nine rectangular reinforced concrete beams dominated by disturbed regions are tested to verify the proposed shear reinforcement approach of the tension field concept. In this approach, the thin steel plate is embedded within shear span to resist shear strength in two different modes: with and without enhancement of reinforcement as stiffeners. All specimens were tested for failure using a four-point load testing arrangement. Test results demonstrate the feasibility of using embedded mild thin steel plate with and without ribs of rebars as tension field action against initiated concrete compression field action to upgrade the section shear capacity. As depicted by experimental results, the provided tension field system can remarkably upgrade the post cracking, stiffness, and ultimate shear capacity of the considered concrete beams. The stringer panel model is considered to verify and confirm strength improvement. The numerical solution is considered to investigate the proposed composite reinforcement provided within concrete deep beams using the concrete damaged plasticity model. The numerical investigation succeeded to depict the generation of tension field action within the suggested embedded steel plates–stiffened rebars composite reinforcement.
23 January 2022 in Asian Journal of Civil Engineering
This study aims to investigate the behavior and strength of self-compacted ferrocement slabs under punching shear load. Experimental results of thirteen square ferrocement slabs of 500×500 mm simply supported on all edges are presented. The main parameters investigated include the volume fraction of reinforcement, slab thickness and size of load-bearing plate. The load deflection and cracking characteristics of the tested slabs are studied and compared. The test results showed that the volume fraction of wire mesh has significant effect on both ultimate load and displacement. The increase of slab thickness leads to decrease in deflection values and increase in stiffness of slabs. Both ductility and stiffness increase as the loaded area size is increased.