Youn-Soo Park

Dr. Youn-Soo Park


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2012 in Computer Aided Surgery
Verified
Journal Article
Open access
PDF file
YMYoung-Wan Moon
Young-Wan Moon
CHChul-Won Ha
Chul-Won Ha
KDKwan-Hong Do
Kwan-Hong Do
CKChang-Young Kim
Chang-Young Kim
JHJeong-Hoon Han
Jeong-Hoon Han
YPYoun-Soo Park
Youn-Soo Park
Introduction: A functional total knee replacement has to be well aligned, which implies that it should lie along the mechanical axis and in the correct axial and rotational planes. Incorrect alignment will lead to abnormal wear, early mechanical loosening, and patellofemoral problems. There has been increased interest of late in total knee arthroplasty with robotic assistance. This study was conducted to determine whether robot-assisted total knee arthroplasty is superior to the conventional surgical method with regard to the precision of implant positioning. Materials and Methods: Twenty knee replacements, comprising ten robot-assisted procedures and ten conventional operations, were performed on ten cadavers. Two experienced surgeons performed the surgeries. Both procedures on each cadaver were performed by the same surgeon. The choice of which procedure was to be performed first was randomized. Following implantation of the prosthesis, the mechanical axis deviation, femoral coronal angle, tibial coronal angle, femoral sagittal angle, tibial sagittal angle, and femoral rotational alignment were measured via 3D CT scanning. These variables were then compared with the preoperatively planned values. Results: In the knees that underwent robot-assisted surgery, the mechanical axis deviation ranged from −1.94° to 2.13° (mean: −0.21°), the femoral coronal angle from 88.08° to 90.99° (mean: 89.81°), the tibial coronal angle from 89.01° to 92.36° (mean: 90.42°), the tibial sagittal angle from 81.72° to 86.24° (mean: 83.20°), and the femoral rotational alignment from 0.02° to 1.15° (mean: 0.52°) in relation to the transepicondylar axis. In the knees that underwent conventional surgery, the mechanical axis deviation ranged from −3.19° to 3.84° (mean: −0.48°), the femoral coronal angle from 88.36° to 92.29° (mean: 90.50°), the tibial coronal angle from 88.15° to 91.51° (mean: 89.83°), the tibial sagittal angle from 80.06° to 87.34° (mean: 84.50°), and the femoral rotational alignment from 0.32° to 4.13° (mean: 2.76°) in relation to the transepicondylar axis. In the conventional knee replacement group, there were two instances of outliers outside the range of 3° varus/valgus for the mechanical axis deviation. The robot-assisted knee replacements showed significantly superior femoral rotational alignment results compared with conventional surgery (p = 0.006). There was no statistically significant difference between robot-assisted and conventional total knee arthroplasty with regard to the other variables. All the measurements showed high intra-observer and inter-observer reliability. Conclusion: Robot-assisted total knee arthroplasty showed excellent precision in the sagittal and coronal planes of the 3D CT scan. In particular, the robot-assisted technique showed better accuracy in femoral rotational alignment compared to the conventional surgery, despite the fact that the surgeons who performed the operations were more experienced and familiar with the conventional method than with robot-assisted surgery. It can thus be concluded that robot-assisted total knee arthroplasty is superior to conventional total knee arthroplasty.

23 July 2018 in Osteoporosis International
Verified
Journal Article
Closed access
PDF file
SLS.-J. Lim
S.-J. Lim
IYI. Yeo
I. Yeo
PYP.-W. Yoon
P.-W. Yoon
JYJ.J. Yoo
J.J. Yoo
KRK.-H. Rhyu
K.-H. Rhyu
YPYoun-Soo Park
Youn-Soo Park

1 January 2016 in Thrombosis and Haemostasis
Verified
Journal Article
Closed access
SKSang-Min Kim
Sang-Min Kim
YMYoung-Wan Moon
Young-Wan Moon
SEUNG JAE LIMSEUNG JAE LIM
SEUNG JAE LIM
DKDong-Wook Kim
Dong-Wook Kim
YPYoun-Soo Park
Youn-Soo Park
Summary: This prospective study was conducted to report the effect of oral factor Xa inhibitor and low-molecular-weight heparin (LMWH) on surgical complications following total hip arthroplasty (THA). The patients with an age < 60 years were randomly assigned to three groups (rivaroxaban, enoxaparin, and placebo) and the patients with an age ≥ 60 years were assigned to two groups (rivaroxaban and enoxaparin). All drug regimens started at 12 hours postoperatively and continued for two weeks after surgery. Primary measure outcome was major surgical wound complications defined as haematoma requiring any intervention, superficial wound infection, deep periprosthetic infection, and increased wound bleeding. Secondary measured outcome included minor surgical complications (swelling, drainage, erythema, and oozing), organ bleeding, and venous thromboembolic (VTE) events. A total of 184 patients aged < 60 years and 167 patients aged ≥ 60 years were included as the analysis population per group. Up to 14 days after surgery, the overall incidence of major surgical complications associated with thromboprophylaxis was 6.5 % (58/886). There were no significant differences in the rate of major surgical complications among all the three groups of the patients aged < 60 years and between two groups of the patients aged ≥ 60 years. For the patients aged < 60 years, wound oozing continued significantly longer in the pharmacological group than in the placebo group, but wound infection did not occur in any case. The VTE events were similar in all the groups.

4 September 2018 in Hip & Pelvis
Verified
Journal Article
Open access
PDF file
CPChan-Woo Park
Chan-Woo Park
SLSeung-Jae Lim
Seung-Jae Lim
YPYoun-Soo Park
Youn-Soo Park
Park CW, et al. Hip Pelvis. 2018 Sep;30(3):147-155. https://doi.org/10.5371/hp.2018.30.3.147

19 June 2011 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
KKKyoung Koh
Kyoung Koh
YMYoung-Wan Moon
Young-Wan Moon
SEUNG JAE LIMSEUNG JAE LIM
SEUNG JAE LIM
HLHyun Il Lee
Hyun Il Lee
JSJae Woo Shim
Jae Woo Shim
YPYoun-Soo Park
Youn-Soo Park

1 October 2020 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
CPChan-Woo Park
Chan-Woo Park
SLSeung-Jae Lim
Seung-Jae Lim
DYDong-Hee Ye
Dong-Hee Ye
YPYoun-Soo Park
Youn-Soo Park