Rooftop buildings, mountain terrains, rivers, and lake beds may be oriented at different azimuths other than due south (in the northern hemisphere), on which photovoltaic (PV) systems may be installed. The present study presents a comprehensive point of view on the relation between the inter-row spacing and the inter-row shading in multiple-row collectors of PV fields; it analytically formulates the inter-row spacing and the associated shading losses for collectors deployed at any azimuth on horizontal, sloped-planed, and oriented toward the south and north, and is supported by the numerical results. Several criteria for the inter-row spacing are applied in the study; among them is a newly introduced criterion appropriate for the collectors deployed at a given azimuth. This study indicates that shorter spacing results in increased shading; minimum shading is obtained for collectors oriented toward the equator; inter-row spacing for maintenance purposes is used in limited dimensions of the PV fields and, usually, in optimal PV system designs; less shading occurs for systems deployed on sloped planes oriented toward the south; less shading is obtained for collectors based on the new criterion, where collectors are deployed at azimuth equal to the solar azimuth, and larger spacing is required for collectors deployed on northern slopes.
The deployment of photovoltaic (PV) systems on rooftops in urban environments may encounter shading on the PV collectors from surrounding walls, acting adversely on the generated electricity of the PV systems. Most studies on the shading of PV systems do not deal analytically with the shading losses of PV collectors affected by walls, fences, and obscuring objects. The present article mathematically formulates shadow expressions for wall and inter-row shading on PV collectors and calculates the percentage of annual shading losses affected by wall heights and azimuth angles, the distances of walls to collectors, and the length and azimuth angles of collectors. This study indicates that the shading losses increase for shorter distances from the collector to the walls and for higher walls. Shading losses may reach 7 percent for wall heights of 4 m and at a distance of 2 m from the collectors to a wall. The results indicate that wall shading dominates inter-row shading.
11 October 2019 in Journal of Solar Energy Engineering
In multiple rows of photovoltaic fields, the rows may be installed with several modules placed along the row width. The verification of the sky view factor model pertains to the second and subsequent rows. Photovoltaic (PV) modules along the row width experience uneven incident diffuse radiation caused by differences in the sky view factor of the modules. The present experimental study verifies first the sky view factor model, and second shows the differences in output power of the PV modules (affected by the sky view factors) placed in different locations along the width of the second row. This work complements the theoretical previous work and emphasizes the importance of the incident diffuse radiation, associated with the sky view factor, on the energy loss of the PV field. Two rows deployed with PV modules were tested on the laboratory roof for several days for different inclination angles and distances between rows. The results show that a top module on a row may generate 8% more power than a bottom module at noontime. The findings of this experimental study have technical significance in designing PV systems.
As photovoltaic (PV) deployment has expanded from rural sites to the built environment, rooftops are increasingly used for electricity generation. In these settings, the visible sky is often partially obstructed by adjacent walls, producing shading that reduces energy yield. This study quantifies the effect of wall shading on incident solar radiation and system losses, and contrasts it with inter-row (mutual) shading experienced by PV arrays in open fields. Systems installed near obscuring walls are subject to both phenomena. To our knowledge, the specific impact of wall shading on PV systems has not been examined comprehensively. We characterize how wall height governs shadow geometry, determine the resulting numbers of shaded and unshaded cells and modules, and assess how shaded modules influence the performance of the remaining modules in a series string. For the parameter set analyzed, annual energy losses are 7.7% due to wall shading and 4% due to inter-row shading, yielding a combined loss of 10.2%. The methods and results provide a practical basis for designers to estimate shading losses and expected energy production for PV systems sited near obscuring walls.
Photovoltaic collectors deployed in multiple rows and near the structure’s walls are obscured from the receiving part of the diffuse skylight. Obscuring part of the diffuse skylight to the collectors decreases the incident diffuse radiation and thus, results in diffuse radiation losses. These losses are associated with the sky view factors. The inter-row diffuse radiation losses are associated with the sky view factor of the collector, and the wall diffuse radiation losses are associated with the sky view factor caused by the wall. The purpose of the present study is to develop mathematical expressions and a methodology for sky view factors of PV systems installed near obscuring walls. The study investigates the effect of the wall height, distance of the wall to the collectors, and collector and wall azimuth angles, on the sky view factors. The study may assist the PV system designer in assessing the contribution of the incident diffuse radiation to the generated electric energy of PV systems installed near obscuring walls. The simulation results indicate that the overall range of the sky view factor variation may be quite noticeable, between 0.97 (without the presence of a wall) and 0.78 (with the presence of a wall), for the parameters used in the study.
The deployment of solar photovoltaic (PV) systems on rooftops in urban environments utilizes the rooftop areas for electricity generation. Rooftops may provide a large amount of empty space that can reduce the use of land for large PV plant installations and other purposes. These deployments may encounter shading on the PV collectors from surrounding building walls, thus reducing the incident direct beam radiation on the PV collectors, resulting in shading losses. Moreover, walls and collector rows block part of the visible sky, reducing the incident diffuse radiation on the collectors, resulting in masking losses. The present study complements previous studies by the authors (see the references) by calculating the incident beam, diffuse and global radiation, and their distribution across the collector rows for four configurations of PV systems installed near obscuring walls. In addition, the article quantifies the shading problem by simulating the shading dimensions and their patterns caused by walls and collector rows. The article is of practical importance for designers of PV systems in urban environments. The simulation results indicate an almost uniform distribution of the incident radiation between the collector rows. On the other hand, the losses may reach 8 percent for a wall height of 4 m for the parameters used in the study.