Jia-lin Yao

Dr. Jia-lin Yao

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2020 in ACS Omega
Verified
Journal Article
Closed access
JYJia-lin Yao
Jia-lin Yao
WQWenjiang Qiang
Wenjiang Qiang
HWHao Wei
Hao Wei
YXYan Xu
Yan Xu
BWBo Wang
Bo Wang
XYXing Yang
Xing Yang

1 January 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
SWsong wang
song wang
JYJIN YAN
JIN YAN
CZCanlin Zhu
Canlin Zhu
JYJia-lin Yao
Jia-lin Yao
QLQiusheng Liu
Qiusheng Liu
XYXing Yang
Xing Yang
Flexible electrodes are extensively used to detect signals in electrocardiography, electroencephalography, electro-ophthalmography, and electromyography, among others. These electrodes can also be used in wearable and implantable medical systems. The collected signals directly affect doctors’ diagnoses of patient etiology and are closely associated with patients’ life safety. Electrodes with low contact impedance can acquire good quality signals. Herein, we established a method of arraying pyramidal microstructures on polydimethylsiloxane (PDMS) substrates to increase the contact area of electrodes, and a parylene transitional layer is coated between PDMS substrates and metal membranes to enhance the bonding force, finally reducing the impedance of flexible electrodes. Experimental results demonstrated that the proposed methods were effective. The contact area of the fabricated electrode increased by 18.15% per unit area, and the contact impedance at 20 Hz to 1 kHz scanning frequency ranged from 23 to 8 kΩ, which was always smaller than that of a commercial electrode. Overall, these results indicated the excellent performance of the fabricated electrode given its low contact impedance and good biocompatibility. This study can also serve as a reference for further electrode research and application in wearable and implantable medical systems.

1 January 2016 in Journal of Nanomaterials
Verified
Journal Article
Open access
PDF file
JYJia-lin Yao
Jia-lin Yao
XYXing Yang
Xing Yang
NSNa Shao
Na Shao
HLHui Luo
Hui Luo
TZTing Zhang
Ting Zhang
WJWu-Gui Jiang
Wu-Gui Jiang
Excellent flexibility, high sensitivity, and low consumption are essential characteristics in flexible microtube pressure sensing occasion, for example, implantable medical devices, industrial pipeline, and microfluidic chip. This paper reports a flexible, highly sensitive, and ultrathin piezoresistive pressure sensor for fluid pressure sensing, whose sensing element is micropatterned films with conductive carbon nanotube layer. The flexible pressure sensor, the thickness of which is 40 ± 10 μm, could be economically fabricated by using biocompatible polydimethylsiloxane (PDMS). Experimental results show that the flexible pressure sensor has high sensitivity (0.047 kPa−1in gas sensing and 5.6 × 10−3 kPa−1in liquid sensing) and low consumption (<180 μW), and the sensor could be used to measure the pressure in curved microtubes.

8 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
KLKai Luo
Kai Luo
WSWenpu Shi
Wenpu Shi
YCYinghao Chen
Yinghao Chen
BWBo Wang
Bo Wang
JYJia-lin Yao
Jia-lin Yao
XYXing Yang
Xing Yang
The real-time monitoring of the working status of drainage tubes is crucial for successful surgical drainage and for informing clinicians of the drainage conditions of patients at different stages, to enable objective diagnosis and treatment. In this study, a method for monitoring the drainage condition of drainage tubes was proposed. The method was based on the principle of capacitance and was developed by analyzing the major states of drainage tubes in the process of drainage. Meanwhile, the principle of interdigital capacitance monitoring drainage was analyzed, and an interdigital capacitance device for the real-time monitoring of the working status of drainage tubes was designed. Ultimately, an experimental system for drainage simulation was established on the basis of the interdigital capacitance device and method for drainage monitoring. Results showed that the interdigital capacitance device for drainage monitoring can identify unobstructed or blocked drainage tubes effectively in real time. The device has a hydrophobic surface, so its electrodes do not undergo electrolysis and pollution due to adhesion. Hence the proposed capacitance-based method for monitoring the working states of drainage tubes has good application prospects in the postoperative drainage of abdominal and thoracic cavities.