Flow-mediated vasodilation (FMV), brachial artery flow (BAF), and brachial artery diameter were evaluated in 30 patients with congestive heart failure before and after cilazapril treatment. While mean pulmonary artery pressure and pulmonary capillary wedge pressure decreased significantly, flow-mediated vasodilation and left ventricular ejection fraction increased significantly following cilazapril administration (P < 0.001). Brachial artery diameter and brachial artery flow did not change following the treatment period (P > 0.05). In conclusion, short-term cilazapril administration improved endothelial function and pulmonary pressure in patients with congestive heart failure.
1 July 2023 in Turkish Journal of Thoracic and Cardiovascular Surgery
Artificial intelligence can be employed in many cardiological applications including image analysis, risk assessment, and patient monitoring. In the catheterization laboratory, it can act as a physician assistant, technician, or co-worker. First, by giving voice commands to the operator of the coronary angiography machine, it can ensure that the C-arm moves to the desired angle. It is able to make recommendations for stent size and type based on the analysis of angiography images which is also possible for peripheral and carotid interventions. For transcatheter aortic valve implantation, it can make recommendations for valve placement and size. Artificial intelligence-based image analysis algorithms can be used to support image analysis during catheter laboratory procedures. The challenges include the need for large, high-quality data sets and the development of accurate, reliable, and interpretable artificial intelligence algorithms.
20 April 2020 in Turkish Journal of Thoracic and Cardiovascular Surgery
We aimed to investigate the potential role of threedimensional printed anatomical models in pre-procedural planning, practice, and selection of carotid artery stent and embolic protection device size and location. A total of 16 patients (10 males, 6 females; mean age 75.6±4.7 years; range, 68 to 81 years) who underwent carotid artery stenting with an embolic protection device between January 2017 and February 2019 were retrospectively analyzed. The sizing was based on intraprocedural angiography findings with the same brand stent using distal protection device. Pre-procedural computed tomography angiography images used for diagnosis were obtained and modeled with three-dimensional printing method. Pre-procedural and threedimensional data regarding the size of stents and protection devices and implantation sites were compared. Measurements obtained from three-dimensional models manually and segmentation images from software were found to be similar and both were smaller than actually used for stent and embolic protection device sizes. The rates of carotid artery stenosis were similar with manual and software methods, but were lower than the quantitative angiographic measurements. Device implantation sites detected by the manual and software methods were different than the actual setting. The planning and practicing of procedure with threedimensional models may reduce the operator-dependent variables, shorten the operation time, decrease X-ray exposure, and increase the procedural success.
1 April 2025 in Turkish Journal of Thoracic and Cardiovascular Surgery
Electronic cigarettes (e-cigarettes) have recently been widely used as a method to conventional smoking cessation or as an alternative, especially among young population. The newly identified E-cigarette, or vaping, product use associated lung injury (EVALI) and the risk of myocardial infarction may lead to catastrophic consequences including death. Herein, we present the case of a ST-elevation myocardial infarction (STEMI) accompanied by Pneumonitis in the setting of E-cigarette use in a 37-year-old male who presented with retrosternal chest pain at rest and shortness of breath that started 2 hours before admission.
22 October 2020 in Turkish Journal of Thoracic and Cardiovascular Surgery
Cannulation of the shorter limb of an abdominal aortic endograft can be demanding. Confirmation of the accurate cannulation is equally challenging. Interventional cardiologists and cardiovascular surgeons may encounter certain difficulties during this procedure. In particular, cardiologists have a wide variety of experience in interventions from coronary practice. This novel method we describe herein consists of peripheral balloon usage in wiring the short limb of an aortic stent graft. In this method, an over-the-wire peripheral balloon is employed to centralize the wire at the gate of the short limb. The centralized wire in three-dimensional arterial lumen can cross the short limb of the graft easily.