Matthias Taupitz

Prof. Matthias Taupitz

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2001 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
SSStephan A. Schmitz
Stephan A. Schmitz
MTMatthias Taupitz
Matthias Taupitz
SWSusanne Wagner
Susanne Wagner
KWKarl‐Jürgen Wolf
Karl‐Jürgen Wolf
DBDirk Beyersdorff
Dirk Beyersdorff
BHBernd Hamm
Bernd Hamm
Experimental data show accumulation of superparamagnetic iron oxide (SPIO) particles in atherosclerotic plaques. SPIO uptake occurred in plaques, suggesting an increased endothelial permeability and macrophage infiltrates as signs of inflammatory plaque activity. We incidentally observed SPIO uptake in aortic and arterial wall segments in patients who had originally received the magnetic resonance (MR) contrast agent for staging lymph node metastases. Twenty patients (19 male, 1 female; mean age, 64; range, 41–78 years) with bladder or prostate cancer underwent MR imaging (MRI) using a T2*‐weighted high‐resolution gradient‐echo sequence prior to and 24–36 hours after intravenous injection of 2.6 mg of Fe/kg of SPIO (Sinerem®). The aorta, both common external and internal iliac, as well as both superficial femoral arteries, were retrospectively analyzed for atherosclerotic wall changes. One patient was excluded. A positive finding was defined as an area of pronounced signal loss on postcontrast images clearly confined to the arterial wall, which was absent in the precontrast examination or increased in size. Such a finding was observed in one to three arteries in 7 of the 19 patients. The pronounced signal loss in the wall of the aorta and pelvic arteries seen in part of an elderly patient population after intravenous SPIO administration strongly suggests that this contrast agent accumulates in human atherosclerotic plaques. J. Magn. Reson. Imaging 2001;14:355–361.

1 July 2004 in Investigative Radiology
Verified
Journal Article
Closed access
MTMatthias Taupitz
Matthias Taupitz
SWSusanne Wagner
Susanne Wagner
JSJörg Schnorr
Jörg Schnorr
IKIrina Kravec
Irina Kravec
HPHerbert Pilgrimm
Herbert Pilgrimm
BHBernd Hamm
Bernd Hamm
To evaluate the safety and pharmacokinetics of a newly developed MR contrast medium consisting of very small superparamagnetic iron oxide particles (VSOP) coated with citrate (VSOP-C184) in a clinical phase I trial. A total of 18 healthy subjects received either VSOP-C184 (core diameter: 4 nm; total diameter: 7 ± 0.15 nm; relaxivities in water at 0.47 T (T1) 18.7 and (T2) 30 L/(mmol*seconds)) at doses of 0.015, 0.045, or 0.075 mmol Fe/kg (n = 5 per dose) or placebo (n = 1 per dose) as intravenous injections. Physical status and vital parameters were recorded, blood samples were collected for clinical chemistry and relaxometry (0.94 T), and urinalyses were performed before and for up to 2 weeks after administration. No serious adverse events occurred. The most pronounced adverse events occurred in 2 subjects of the highest dose group 45–50 minutes after injection. These were a drop in blood pressure and a drop in oxygen saturation, which were considered to be possibly drug-related and rapidly resolved without medication. Otherwise, no relevant changes in vital and laboratory parameters were observed. The parameters of iron metabolism exhibited short-term, dose-related changes. The injection of VSOP-C184 decreased T1 relaxation time of blood below 100 milliseconds for 18 minutes after a dose of 0.045 μmol Fe/kg and for 60 minutes after 0.075 μmol Fe/kg. The favorable data on the safety, tolerability, and efficacy of VSOP-C184 justify further clinical phase II and III trials as a contrast medium for MRI.

18 July 2011 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
MWMoritz Wagner
Moritz Wagner
SWSusanne Wagner
Susanne Wagner
JSJörg Schnorr
Jörg Schnorr
ESEyk Schellenberger
Eyk Schellenberger
DKDietmar Kivelitz
Dietmar Kivelitz
MTMatthias Taupitz
Matthias Taupitz
Purpose: To evaluate very small superparamagnetic iron oxide particles (VSOP‐C184) as blood‐pool contrast agent for coronary MR angiography (CMRA) in humans.Materials and Methods: Six healthy volunteers and 14 patients with suspected coronary artery disease underwent CMRA after administration of VSOP‐C184 at the following doses: 20 μmol Fe/kg (4 patients), 40 μmol Fe/kg (5 patients), 45 μmol Fe/kg (6 healthy volunteers), and 60 μmol Fe/kg (5 patients). In healthy volunteers, contrast‐to‐noise ratio (CNR), signal‐to‐noise ratio (SNR), and vessel edge definition (VED) of contrast‐enhanced CMRA were compared with non–contrast‐enhanced CMRA. In patients, a per‐segment intention‐to‐diagnose evaluation of contrast‐enhanced CMRA for detection of significant coronary stenosis (≥50%) was performed.Results: Three healthy volunteers (45 μmol Fe/kg VSOP‐C184) and two patients (60 μmol Fe/kg VSOP‐C184) had adverse events of mild or moderate intensity. VSOP‐C184 significantly increased CNR (15.1 ± 4.6 versus 6.9 ± 1.9; P = 0.010), SNR (21.7 ± 5.3 versus 15.4 ± 1.6; P = 0.048), and VED (2.3 ± 0.6 versus 1.2 ± 0.2; P < 0.001) compared with non–contrast‐enhanced CMRA. In patients, contrast‐enhanced CMRA yielded sensitivity, specificity, and diagnostic accuracy for detection of significant coronary stenosis of 86.7%, 71.0%, 73.1%, respectively.Conclusion: CMRA using VSOP‐C184 was feasible and yielded moderate diagnostic accuracy for detection of significant coronary stenosis within this proof‐of‐concept setting. J. Magn. Reson. Imaging 2011;.

1 May 2001 in European Radiology
Verified
Journal Article
Closed access
PDF file
AMAhmed-Emad Mahfouz
Ahmed-Emad Mahfouz
HSHanan Sherif
Hanan Sherif
ASAmel Saad
Amel Saad
MTMatthias Taupitz
Matthias Taupitz
SFSergej Filimonow
Sergej Filimonow
BHBernd Hamm
Bernd Hamm

6 August 2009 in Journal of Neuroinflammation
Verified
Journal Article
Open access
PDF file
ETEva Tysiak
Eva Tysiak
PAPatrick Asbach
Patrick Asbach
OAOrhan Aktas
Orhan Aktas
HWHelmar Waiczies
Helmar Waiczies
MSMaureen Smyth
Maureen Smyth
JWJens Wuerfel
Jens Wuerfel
Background: Gadopentate dimeglumine (Gd-DTPA) enhanced magnetic resonance imaging (MRI) is widely applied for the visualization of blood brain barrier (BBB) breakdown in multiple sclerosis and its animal model, experimental autoimmune encephalomyelitis (EAE). Recently, the potential of magnetic nanoparticles to detect macrophage infiltration by MRI was demonstrated. We here investigated a new class of very small superparamagnetic iron oxide particles (VSOP) as novel contrast medium in murine adoptive-transfer EAE. Methods: EAE was induced in 17 mice via transfer of proteolipid protein specific T cells. MR images were obtained before and after application of Gd-DTPA and VSOP on a 7 Tesla rodent MR scanner. The enhancement pattern of the two contrast agents was compared, and correlated to histology, including Prussian Blue staining for VSOP detection and immunofluorescent staining against IBA-1 to identify macrophages/microglia. Results: Both contrast media depicted BBB breakdown in 42 lesions, although differing in plaques appearances and shapes. Furthermore, 13 lesions could be exclusively visualized by VSOP. In the subsequent histological analysis, VSOP was localized to microglia/macrophages, and also diffusely dispersed within the extracellular matrix. Conclusion: VSOP showed a higher sensitivity in detecting BBB alterations compared to Gd-DTPA enhanced MRI, providing complementary information of macrophage/microglia activity in inflammatory plaques that has not been visualized by conventional means.

1 January 2002 in Radiology
Verified
Journal Article
Closed access
MTMatthias Taupitz
Matthias Taupitz
JSJörg Schnorr
Jörg Schnorr
SWSusanne Wagner
Susanne Wagner
CAClaudia Abramjuk
Claudia Abramjuk
HPHerbert Pilgrimm
Herbert Pilgrimm
BHBernd Hamm
Bernd Hamm
To evaluate the signal-enhancing characteristics of monomer-coated very small superparamagnetic iron oxide (SPIO) particles used as a blood pool contrast medium for magnetic resonance (MR) angiography in the coronary arteries. The particles used in this study were coated with citrate as the monomer (VSOP-C91). The particles have a total diameter of 7 nm and show the following relaxivities at 0.47 T: T1, 19 L/mmol. sec(-1); T2, 29 L/mmol. sec(-1). Fifteen cardiac MR examinations were performed at 1.5 T in five pigs. Images were acquired from immediately to 35 minutes (equilibrium phase) after intravenous injection of gadopentetate dimeglumine, gadobenate dimeglumine, and the very small SPIO particles (n = 5 for each substance). Immediately after administration of gadopentetate dimeglumine, gadobenate dimeglumine, and the very small SPIO particles, respectively, increases in the signal-to-noise ratio in blood were 94%, 103%, and 102% and in myocardium were 83%, 83%, and 29% (P <.05, very small SPIO particles versus the low-molecular-weight gadolinium-based compounds). Differences in the blood-to-myocardium contrast-to-noise ratio and visualization of the coronary arteries and their branches were also significant. VSOP-C91 significantly improves visualization of the coronary arteries at MR angiography from immediately to 35 minutes after injection.