Zafeiris Louvaris

Dr. Zafeiris Louvaris

Research Group for Rehabilitation in Internal Disorders, KU Leuven, Leuven, Belgium
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HRHans Van Remoortel
Hans Van Remoortel
YRYogini Raste
Yogini Raste
Zafeiris LouvarisZafeiris Louvaris
Zafeiris Louvaris
SGSantiago Giavedoni
Santiago Giavedoni
CBChris Burtin
Chris Burtin
OCon behalf of PROactive consortium
on behalf of PROactive consortium
Reduced physical activity is an important feature of Chronic Obstructive Pulmonary Disease (COPD). Various activity monitors are available but their validity is poorly established. The aim was to evaluate the validity of six monitors in patients with COPD. We hypothesized triaxial monitors to be more valid compared to uniaxial monitors. Thirty-nine patients (age 68±7years, FEV1 54±18%predicted) performed a one-hour standardized activity protocol. Patients wore 6 monitors (Kenz Lifecorder (Kenz), Actiwatch, RT3, Actigraph GT3X (Actigraph), Dynaport MiniMod (MiniMod), and SenseWear Armband (SenseWear)) as well as a portable metabolic system (Oxycon Mobile). Validity was evaluated by correlation analysis between indirect calorimetry (VO2) and the monitor outputs: Metabolic Equivalent of Task [METs] (SenseWear, MiniMod), activity counts (Actiwatch), vector magnitude units (Actigraph, RT3) and arbitrary units (Kenz) over the whole protocol and slow versus fast walking. Minute-by-minute correlations were highest for the MiniMod (r = 0.82), Actigraph (r = 0.79), SenseWear (r = 0.73) and RT3 (r = 0.73). Over the whole protocol, the mean correlations were best for the SenseWear (r = 0.76), Kenz (r = 0.52), Actigraph (r = 0.49) and MiniMod (r = 0.45). The MiniMod (r = 0.94) and Actigraph (r = 0.88) performed better in detecting different walking speeds. The Dynaport MiniMod, Actigraph GT3X and SenseWear Armband (all triaxial monitors) are the most valid monitors during standardized physical activities. The Dynaport MiniMod and Actigraph GT3X discriminate best between different walking speeds.

8 February 2013 in European Respiratory Journal
Verified
Journal Article
Open access
PDF file
RRRoberto A. Rabinovich
Roberto A. Rabinovich
Zafeiris LouvarisZafeiris Louvaris
Zafeiris Louvaris
YRYogini Raste
Yogini Raste
DLDaniel Langer
Daniel Langer
HRHans Van Remoortel
Hans Van Remoortel
TTThierry Troosters
Thierry Troosters
Symptoms during physical activity and physical inactivity are hallmarks of chronic obstructive pulmonary disease (COPD). Our aim was to evaluate the validity and usability of six activity monitors in patients with COPD against the doubly labelled water (DLW) indirect calorimetry method.80 COPD patients (mean±sdage 68±6 years and forced expiratory volume in 1 s 57±19% predicted) recruited in four centres each wore simultaneously three or four out of six commercially available monitors validated in chronic conditions for 14 consecutive days.A priorivalidity criteria were defined. These included the ability to explain total energy expenditure (TEE) variance through multiple regression analysis, using TEE as the dependent variable with total body water (TBW) plus several physical activity monitor outputs as independent variables; and correlation with activity energy expenditure (AEE) measured by DLW.The Actigraph GT3X (Actigraph LLC, Pensacola, FL, USA), and DynaPort MoveMonitor (McRoberts BV, The Hague, the Netherlands) best explained the majority of the TEE variance not explained by TBW (53% and 70%, respectively) and showed the most significant correlations with AEE (r=0.71, p<0.001 and r=0.70, p<0.0001, respectively).The results of this study should guide users in choosing valid activity monitors for research or for clinical use in patients with chronic diseases such as COPD.

9 July 2012 in International Journal of Behavioral Nutrition and Physical Activity
Verified
Journal Article
Open access
PDF file
HRHans Van Remoortel
Hans Van Remoortel
SGSantiago Giavedoni
Santiago Giavedoni
YRYogini Raste
Yogini Raste
CBChris Burtin
Chris Burtin
Zafeiris LouvarisZafeiris Louvaris
Zafeiris Louvaris
PCPROactive consortium
PROactive consortium
The assessment of physical activity in healthy populations and in those with chronic diseases is challenging. The aim of this systematic review was to identify whether available activity monitors (AM) have been appropriately validated for use in assessing physical activity in these groups. Following a systematic literature search we found 134 papers meeting the inclusion criteria; 40 conducted in a field setting (validation against doubly labelled water), 86 in a laboratory setting (validation against a metabolic cart, metabolic chamber) and 8 in a field and laboratory setting. Correlation coefficients between AM outcomes and energy expenditure (EE) by the criterion method (doubly labelled water and metabolic cart/chamber) and percentage mean differences between EE estimation from the monitor and EE measurement by the criterion method were extracted. Random-effects meta-analyses were performed to pool the results across studies where possible. Types of devices were compared using meta-regression analyses. Most validation studies had been performed in healthy adults (n = 118), with few carried out in patients with chronic diseases (n = 16). For total EE, correlation coefficients were statistically significantly lower in uniaxial compared to multisensor devices. For active EE, correlations were slightly but not significantly lower in uniaxial compared to triaxial and multisensor devices. Uniaxial devices tended to underestimate TEE (−12.07 (95%CI; -18.28 to −5.85) %) compared to triaxial (−6.85 (95%CI; -18.20 to 4.49) %, p = 0.37) and were statistically significantly less accurate than multisensor devices (−3.64 (95%CI; -8.97 to 1.70) %, p<0.001). TEE was underestimated during slow walking speeds in 69% of the lab validation studies compared to 37%, 30% and 37% of the studies during intermediate, fast walking speed and running, respectively. The high level of heterogeneity in the validation studies is only partly explained by the type of activity monitor and the activity monitor outcome. Triaxial and multisensor devices tend to be more valid monitors. Since activity monitors are less accurate at slow walking speeds and information about validated activity monitors in chronic disease populations is lacking, proper validation studies in these populations are needed prior to their inclusion in clinical trials.

30 January 2017 in Thorax
Verified
Journal Article
Open access
PDF file
HDHeleen Demeyer
Heleen Demeyer
Zafeiris LouvarisZafeiris Louvaris
Zafeiris Louvaris
AFA Frei
A Frei
RRR A Rabinovich
R A Rabinovich
CJC de Jong
C de Jong
TTT Troosters
T Troosters
Rationale Reduced physical activity (PA) in patients with COPD is associated with a poor prognosis. Increasing PA is a key therapeutic target, but thus far few strategies have been found effective in this patient group. Objectives To investigate the effectiveness of a 12-week semiautomated telecoaching intervention on PA in patients with COPD in a multicentre European randomised controlled trial. Methods 343 patients from six centres, encompassing a wide spectrum of disease severity, were randomly allocated to either a usual care group (UCG) or a telecoaching intervention group (IG) between June and December 2014. This 12-week intervention included an exercise booklet and a step counter providing feedback both directly and via a dedicated smartphone application. The latter provided an individualised daily activity goal (steps) revised weekly and text messages as well as allowing occasional telephone contacts with investigators. PA was measured using accelerometry during 1 week preceding randomisation and during week 12. Secondary outcomes included exercise capacity and health status. Analyses were based on modified intention to treat. Main results Both groups were comparable at baseline in terms of factors influencing PA. At 12 weeks, the intervention yielded a between-group difference of mean, 95% CI (lower limit – upper limit; ll-ul) +1469, 95% CI (971 to 1965) steps/day and +10.4, 95% CI (6.1 to 14.7) min/day moderate PA; favouring the IG (all p≤0.001). The change in 6-min walk distance was significantly different (13.4, 95% CI (3.40 to 23.5) m, p<0.01), favouring the IG. In IG patients, an improvement could be observed in the functional state domain of the clinical COPD questionnaire (p=0.03) compared with UCG. Other health status outcomes did not differ. Conclusions The amount and intensity of PA can be significantly increased in patients with COPD using a 12-week semiautomated telecoaching intervention including a step counter and an application installed on a smartphone. Trial registration number: NCT02158065.

25 May 2017 in European Respiratory Journal
Verified
Journal Article
Closed access
PDF file
MVMaroula Vasilopoulou
Maroula Vasilopoulou
APAndriana I. Papaioannou
Andriana I. Papaioannou
GKGeorgios Kaltsakas
Georgios Kaltsakas
Zafeiris LouvarisZafeiris Louvaris
Zafeiris Louvaris
NCNikolaos Chynkiamis
Nikolaos Chynkiamis
IVIoannis Vogiatzis
Ioannis Vogiatzis
Nicotine, the primary addictive substance in tobacco, is widely abused. Relapse to cues associated with nicotine results in increased glutamate release within nucleus accumbens core (NAcore), modifying synaptic plasticity of medium spiny neurons (MSNs) which contributes to reinstatement of nicotine seeking. However, the role of cholinergic interneurons (ChIs) within the NAcore in mediating these neurobehavioral processes in unknown. ChIs represent less than 1% of the accumbens neuronal population yet are activated during drug seeking and reward-predicting events. Thus, we hypothesized that ChIs may play a significant role in mediating glutamatergic plasticity that underlies nicotine seeking behavior. Using chemogenetics transgenic rats that express Cre under the control of the choline acetyltransferase (ChAT) promoter, ChIs were bi-directionally manipulated prior to cue-induced reinstatement. Following nicotine self-administration and extinction training, ChIs were activated or inhibited prior to a cue reinstatement session. Following reinstatement, whole-cell electrophysiology from NAcore MSNs was used to assess changes in plasticity, measured via α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid (AMPA) / N-Methyl-D-Aspartate (NMDA) (A/N) ratios. Chemogenetic inhibition of ChIs inhibited cued nicotine seeking and resulted in decreased A/N, whereas activation of ChIs had no effect, demonstrating that ChI inhibition prevents transient synaptic potentiation (t-SP) associated with cue-induced nicotine seeking. To assess potential underlying mechanisms, accumbens α4β2- and α7-containing nicotinic ACh receptors (nAChRs) were pharmacologically inhibited and MSN synaptic morphology was assessed following reinstatement. Inhibition of both nAChR subtypes prevented cue-induced nicotine seeking and t-SP (measured via changes in spine head diameter). Together, these results demonstrate that these neurons mediate cue-induced nicotine reinstatement and underlying synaptic plasticity within the NAcore.

28 May 2015 in European Respiratory Journal
Verified
Journal Article
Open access
PDF file
EGElena Gimeno-Santos
Elena Gimeno-Santos
YRYogini Raste
Yogini Raste
HDHeleen Demeyer
Heleen Demeyer
Zafeiris LouvarisZafeiris Louvaris
Zafeiris Louvaris
CJCorina de Jong
Corina de Jong
JGJudith Garcia-Aymerich
Judith Garcia-Aymerich
No current patient-centred instrument captures all dimensions of physical activity in chronic obstructive pulmonary disease (COPD). Our objective was item reduction and initial validation of two instruments to measure physical activity in COPD.Physical activity was assessed in a 6-week, randomised, two-way cross-over, multicentre study using PROactive draft questionnaires (daily and clinical visit versions) and two activity monitors. Item reduction followed an iterative process including classical and Rasch model analyses, and input from patients and clinical experts.236 COPD patients from five European centres were included. Results indicated the concept of physical activity in COPD had two domains, labelled “amount” and “difficulty”. After item reduction, the daily PROactive instrument comprised nine items and the clinical visit contained 14. Both demonstrated good model fit (person separation index >0.7). Confirmatory factor analysis supported the bidimensional structure. Both instruments had good internal consistency (Cronbach's α>0.8), test–retest reliability (intraclass correlation coefficient ≥0.9) and exhibited moderate-to-high correlations (r>0.6) with related constructs and very low correlations (r<0.3) with unrelated constructs, providing evidence for construct validity.Daily and clinical visit “PROactive physical activity in COPD” instruments are hybrid tools combining a short patient-reported outcome questionnaire and two activity monitor variables which provide simple, valid and reliable measures of physical activity in COPD patients.