Perumal Raja Sivakumar

Dr. Perumal Raja Sivakumar

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2014 in Water Resources Management
Verified
Journal Article
Closed access
PDF file
PSPerumal Raja Sivakumar
Perumal Raja Sivakumar
RPR. K. Prasad
R. K. Prasad

30 December 2014 in Water Resources Management
Verified
Journal Article
Closed access
PDF file
PSPerumal Raja Sivakumar
Perumal Raja Sivakumar
RPR. K. Prasad
R. K. Prasad

11 November 2015 in Water Resources Management
Verified
Journal Article
Closed access
PDF file
PSPerumal Raja Sivakumar
Perumal Raja Sivakumar
RPR. K. Prasad
R. K. Prasad
SCS. Chandramouli
S. Chandramouli

1 June 2020 in Journal of Water Resources Planning and Management
Verified
Journal Article
Closed access
PSPerumal Raja Sivakumar
Perumal Raja Sivakumar
NGNikolai B. Gorev
Nikolai B. Gorev
TTTiku Tanyimboh
Tiku Tanyimboh
IKInna F. Kodzhespirova
Inna F. Kodzhespirova
CSC. R. Suribabu
C. R. Suribabu
NTNeelakantan R Thurvas
Neelakantan R Thurvas
EPANET 2 software has been widely used among researchers and practitioners from its inception for hydraulic analysis. This technical note presents a method to simulate pressure-dependent volume-based demands in a single extended-period simulation run of EPANET 2. In the proposed method, artificial strings made up of a pipe with a minor loss, pressure-sustaining valve, pipe of negligible resistance, and tank are added to the demand nodes before running the hydraulic analysis. The time required to satisfy a volume-based demand is determined as the time required to fill the artificial tank connected to the demand node for normal and pressure-deficient conditions. All the simulations were carried out using the available functions of the graphical user interface of EPANET 2. The proposed method was applied to a two-source looped network available from the literature and additionally compared with an existing method available in the literature using two example networks.

14 March 2019 in Drinking Water Engineering and Science
Verified
Journal Article
Open access
PDF file
SRSURIBABU CONETY RAVI
SURIBABU CONETY RAVI
NTNeelakantan R Thurvas
Neelakantan R Thurvas
PSPerumal Raja Sivakumar
Perumal Raja Sivakumar
DPDiego Paez
Diego Paez
Pressure-driven analysis (PDA) of water distribution networks necessitates an assessment of the supplying capacity of a network within the minimum and required pressure ranges. Pressure-deficient conditions happen due to the uncertainty of nodal demands, failure of electromechanical components, diversion of water, aging of pipes, permanent increase in the demand at certain supply nodes, fire demand, etc. As the demand-driven analysis (DDA) solves the governing equations without any bound on pressure head, it fails to replicate the real scenario, particularly when the network experiences pressure-deficient situations. Numerous researchers formulated different head–discharge relations and used them iteratively with demand-driven software, while some other approaches solve them by incorporating this relation within the analysis algorithms. Several attempts have been made by adding fictitious network elements like reservoirs, check valves (CVs), flow control valves (FCVs), emitters, dummy nodes and pipes of negligible length (i.e., negligible pressure loss) to assess the supplying capability of a network under pressure-deficient conditions using demand-driven simulation software. This paper illustrates a simple way of assessing the supplying capacity of demand nodes (DNs) under pressure-deficient conditions by assigning the respective emitter coefficient only for those nodes facing a pressure-deficit condition. The proposed method is tested with three benchmark networks, and it is able to simulate the network without addition of any fictitious network elements or changing the source code of the software like EPANET. Though the proposed approach is an iterative one, the computational burden of adding artificial elements in the other methods is avoided and is hence useful for analyzing large networks.

1 May 2021 in Journal of Water Resources Planning and Management
Verified
Journal Article
Closed access
PDF file
NGNikolai B. Gorev
Nikolai B. Gorev
VGVyacheslav N. Gorev
Vyacheslav N. Gorev
IKInna F. Kodzhespirova
Inna F. Kodzhespirova
ISIgor A. Shedlovsky
Igor A. Shedlovsky
PSPerumal Raja Sivakumar
Perumal Raja Sivakumar
This technical note presents a technique for the pressure-driven analysis (PDA) of water distribution networks with flow- and pressure-regulating valves. The technique is a combination of a PDA method based on adding artificial components (a pipe with a check valve, a flow control valve, and an emitter) to each demand node and a hybrid simulator that models valves as pipes of variable resistance in cases where the EPANET 2.0 valve treatment heuristics fails. The examples considered demonstrate that the proposed PDA technique may be an alternative to EPANET 2.2, the latest version of EPANET 2.0 with a PDA option, in cases where the latter is not applicable or fails to compute the correct solution.