Holger Zipprich

Holger Zipprich


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2008 in Head & Face Medicine
Verified
Journal Article
Open access
PDF file
RDRita Depprich
Rita Depprich
HZHolger Zipprich
Holger Zipprich
Michelle Alicia OmmerbornMichelle Alicia Ommerborn
Michelle Alicia Ommerborn
CNChristian Naujoks
Christian Naujoks
HWHans-Peter Wiesmann
Hans-Peter Wiesmann
JHJörg Handschel
Jörg Handschel
Background: Titanium and titanium alloys are widely used for fabrication of dental implants. Since the material composition and the surface topography of a biomaterial play a fundamental role in osseointegration, various chemical and physical surface modifications have been developed to improve osseous healing. Zirconia-based implants were introduced into dental implantology as an altenative to titanium implants. Zirconia seems to be a suitable implant material because of its tooth-like colour, its mechanical properties and its biocompatibility. As the osseointegration of zirconia implants has not been extensively investigated, the aim of this study was to compare the osseous healing of zirconia implants with titanium implants which have a roughened surface but otherwise similar implant geometries. Methods: Forty-eight zirconia and titanium implants were introduced into the tibia of 12 minipigs. After 1, 4 or 12 weeks, animals were sacrificed and specimens containing the implants were examined in terms of histological and ultrastructural techniques. Results: Histological results showed direct bone contact on the zirconia and titanium surfaces. Bone implant contact as measured by histomorphometry was slightly better on titanium than on zirconia surfaces. However, a statistically significant difference between the two groups was not observed. Conclusion: The results demonstrated that zirconia implants with modified surfaces result in an osseointegration which is comparable with that of titanium implants.

8 December 2008 in Head & Face Medicine
Verified
Journal Article
Open access
PDF file
RDRita Depprich
Rita Depprich
Michelle Alicia OmmerbornMichelle Alicia Ommerborn
Michelle Alicia Ommerborn
HZHolger Zipprich
Holger Zipprich
CNChristian Naujoks
Christian Naujoks
JHJörg Handschel
Jörg Handschel
UMUlrich Meyer
Ulrich Meyer
Background: Osseointegration is crucial for the long-term success of dental implants and depends on the tissue reaction at the tissue-implant interface. Mechanical properties and biocompatibility make zirconia a suitable material for dental implants, although surface processings are still problematic. The aim of the present study was to compare osteoblast behavior on structured zirconia and titanium surfaces under standardized conditions. Methods: The surface characteristics were determined by scanning electron microscopy (SEM). In primary bovine osteoblasts attachment kinetics, proliferation rate and synthesis of bone-associated proteins were tested on different surfaces. Results: The results demonstrated that the proliferation rate of cells was significantly higher on zirconia surfaces than on titanium surfaces (p < 0.05; Student's t-test). In contrast, attachment and adhesion strength of the primary cells was significant higher on titanium surfaces (p < 0.05; U test). No significant differences were found in the synthesis of bone-specific proteins. Ultrastructural analysis revealed phenotypic features of osteoblast-like cells on both zirconia and titanium surfaces. Conclusion: The study demonstrates distinct effects of the surface composition on osteoblasts in culture. Zirconia improves cell proliferation significantly during the first days of culture, but it does not improve attachment and adhesion strength. Both materials do not differ with respect to protein synthesis or ultrastructural appearance of osteoblasts. Zirconium oxide may therefore be a suitable material for dental implants.

1 June 2013 in Implant Dentistry
Verified
Journal Article
Closed access
PSPD Dr. Dr. Markus Schlee
PD Dr. Dr. Markus Schlee
DRDaniel Rothamel
Daniel Rothamel
To evaluate handling and healing patterns of customized allogenic bone blocks for vertical and horizontal alveolar defect augmentation. In 2 patients, 3 combined horizontal and vertical post-foraminal mandibular defects were grafted using computer-aided design (CAD) trimmed individual block grafts, 3D-designed on preoperative computed tomography scans. After a healing period of 6 months, graft resorption was measured and bone trephines were taken in progress of implant bed preparation. Four months later, implants were restored with single crowns. Moreover, clinical and radiological implant parameters were assessed 6 and 12 months after restorative rehabilitation. Uneventful healing was observed in 2 of the 3 cases. A partial exposure of 1 block after 8 weeks could be successfully treated by block reduction and application of a soft tissue graft. Histological evaluation revealed predictable bone formation within all augmented areas, and both patient satisfaction and long-term stability parameters were considered excellent. It was concluded that the application of individual CAD allografts supports bone formation at deficient sites with reduced patient morbidity, decreased surgery time, and high patient acceptance.

7 November 2019 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
PSPD Dr. Dr. Markus Schlee
PD Dr. Dr. Markus Schlee
FRFlorian Rathe
Florian Rathe
UBUrs Brodbeck
Urs Brodbeck
CRChristoph Ratka
Christoph Ratka
PWPaul Weigl
Paul Weigl
HZHolger Zipprich
Holger Zipprich
Objectives: The present randomized clinical trial assesses the six-month outcomes following surgical regenerative therapy of periimplantitis lesions using either an electrolytic method (EC) to remove biofilms or a combination of powder spray and electrolytic method (PEC). Materials and Methods: 24 patients with 24 implants suffering from peri-implantitis with any type of bone defect were randomly treated by EC or PEC. Bone defects were augmented with a mixture of natural bone mineral and autogenous bone and left for submerged healing. The distance from implant shoulder to bone was assessed at six defined points at baseline (T0) and after six months at uncovering surgery (T1) by periodontal probe and standardized x-rays. Results: One implant had to be removed at T1 because of reinfection and other obstacles. None of the other implants showed signs of inflammation. Bone gain was 2.71 ± 1.70 mm for EC and 2.81 ± 2.15 mm for PEC. No statistically significant difference between EC and PEC was detected. Significant clinical bone fill was observed for all 24 implants. Complete regeneration of bone was achieved in 12 implants. Defect morphology impacted the amount of regeneration. Conclusion: EC needs no further mechanical cleaning by powder spray. Complete re-osseointegration in peri-implantitis cases is possible.

2 November 2018 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
PDF file
SBSven Marcus Beschnidt
Sven Marcus Beschnidt
CCClaudio Cacaci
Claudio Cacaci
KDKerem Dedeoglu
Kerem Dedeoglu
DHDetlef Hildebrand
Detlef Hildebrand
HHHelfried Hulla
Helfried Hulla
KAKarl-Ludwig Ackermann
Karl-Ludwig Ackermann
The performance of dental implants in controlled clinical studies is often investigated in homogenous populations. Observational studies are necessary to evaluate the outcome of implant restorations placed in real-life situations, according to standard practice, and to assess the needs of the patients. The aim of this non-interventional study was to reveal the survival, success, and general performance of CAMLOG SCREW-LINE implants and their restorations in daily dental practice. Seventeen private practices across five countries participated in this prospective multicenter study. Patients received implants in the maxilla and mandible which were restored either with platform-matching or platform-switching abutments. Patients were followed-up for up to 5 years post-loading. Radiographs and clinical parameters were evaluated and patient satisfaction was evaluated. From a total of 196 patients planned, 185 patients with 271 implants were restored with abutments and fulfilled the follow-up inclusion criteria. Three implant failures were recorded, resulting in a cumulative survival rate of 98.6% after 5 years post-loading. One persistent complication of peri-implantitis occurred. The soft tissue health remained stable, and the papilla height improved after loading. At 5-year follow-up, the mean crestal bone loss was − 0.28 ± 0.60 mm; over 99% of patients reported satisfaction with the restoration as excellent or good. Implants placed and restored with both platform-matching and platform-switching abutments in daily dental private practice achieved excellent clinical outcomes with highly satisfied patients after 5 years of function, confirming the results obtained in well-controlled clinical trials.

3 September 2017 in Journal of Investigative and Clinical Dentistry
Verified
Journal Article
Closed access
PDF file
PSPD Dr. Dr. Markus Schlee
PD Dr. Dr. Markus Schlee
TSTill Schad
Till Schad
JKJan H. Koch
Jan H. Koch
PCPhilippe C. Cattin
Philippe C. Cattin
FRFlorian Rathe
Florian Rathe