Argon Chen

Prof. Argon Chen

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2007 in International Journal of Production Research
Verified
Journal Article
Closed access
ACArgon Chen
Argon Chen
GWG. S. Wu
G. S. Wu
An often seen practice of preventive maintenance (PM) is to construct a machine's reliability model based on its historical failure records. The reliability model is then used to determine the PM schedule by minimizing the machine's long-run operation cost or average machine downtime. Machines in many hi-tech manufacturing sectors are using sophisticated sensor technologies to provide sufficient immediate online data for real-time observation of equipment condition. Not only is the historical data but also the real time condition now available for scheduling a more effective PM policy. This research is to determine an effective PM policy based on real-time observations of equipment condition. We first use the multivariate process capability index to integrate the equipment's multiple parameters into an overall equipment health index. This health index serves as the basis for real-time health prognosis under an aging Markovian deterioration model. A dynamic PM schedule is then determined based on the health prognosis.

20 October 2016 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MWMing-Hsun Wu
Ming-Hsun Wu
CCChiung-Nien Chen
Chiung-Nien Chen
KCKuen-Yuan Chen
Kuen-Yuan Chen
MHMing-Chih Ho
Ming-Chih Ho
HTHao-Chih Tai
Hao-Chih Tai
KCKing-Jen Chang
King-Jen Chang
Hypoechogenicity has been described qualitatively and is potentially subject to intra- and inter-observer variability. The aim of this study was to clarify whether quantitative echoic indexes (EIs) are useful for the detection of malignant thyroid nodules. Overall, 333 participants with 411 nodules were included in the final analysis. Quantification of echogenicity was performed using commercial software (AmCAD-UT; AmCad BioMed, Taiwan). The coordinates of three defined regions, the nodule, thyroid parenchyma, and strap muscle regions, were recorded in the database separately for subsequent analysis. And the results showed that ultrasound echogenicity (US-E), as assessed by clinicians, defined hypoechogenicity as an independent factor for malignancy. The EI, adjusted EI (EIN-T; EIN-M) and automatic EI(N-R)/R values between benign and malignant nodules were all significantly different, with lower values for malignant nodules. All of the EIs showed similar percentages of sensitivity and specificity and had better accuracies than US-E. In conclusion, the proposed quantitative EI seems more promising to constitute an important advancement than the conventional qualitative US-E in allowing for a more reliable distinction between benign and malignant thyroid nodules.

1 November 2014 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
KCKuen-Yuan Chen
Kuen-Yuan Chen
CCChiung-Nien Chen
Chiung-Nien Chen
MWMing-Hsun Wu
Ming-Hsun Wu
MHMing-Chih Ho
Ming-Chih Ho
HTHao-Chih Tai
Hao-Chih Tai
KCKing-Jen Chang
King-Jen Chang

22 December 2006 in International Journal of Production Research
Verified
Journal Article
Closed access
DCDavid Chiang
David Chiang
RGRuey-Shan Guo
Ruey-Shan Guo
ACArgon Chen
Argon Chen
MCMeng-Tse Cheng
Meng-Tse Cheng
CCCHENG-BANG CHEN
CHENG-BANG CHEN
As a semiconductor supply chain becomes widespread and the competition pressure is very fierce, the detrimental effects of increasing varieties and variations are magnified in the supply chain. But many important issues, such as different service priorities, adaptability, controllability and scalability of performance metrics, have not been addressed in the literature. Conventional modelling techniques of supply chain operations are no longer effective for supply chain configuration. Therefore, a proposed empirical model was first built to catch up the relationship between supply-chain configuration and metrics under the influence of the variability sources. Next, an optimal supply chain configuration model is formulated as a polynomial goal programming model to accommodate different goal objectives. Finally, an efficient solution methodology is further developed to find out the optimal supply chain configuration. Our results show that our proposed approach can easily be adapted to the practices in semiconductor supply chain, and the solution methodology developed in this paper is truly promising.

6 February 2020 in Cancers
Verified
Journal Article
Open access
PDF file
MWMing-Hsun Wu
Ming-Hsun Wu
KCKuen-Yuan Chen
Kuen-Yuan Chen
SSShyang-Rong Shih
Shyang-Rong Shih
MHMing-Chih Ho
Ming-Chih Ho
HTHao-Chih Tai
Hao-Chih Tai
CCChiung-Nien Chen
Chiung-Nien Chen
Physicians use sonographic characteristics as a reference for the possible diagnosis of thyroid cancers. The purpose of this study was to investigate whether physicians were more effective in their tentative diagnosis based on the information provided by a computer-aided detection (CAD) system. A computer compared software-defined and physician-adjusted tumor loci. A multicenter, multireader, and multicase (MRMC) study was designed to compare clinician performance without and with the use of CAD. Interobserver variability was also analyzed. Excellent, satisfactory, and poor segmentations were observed in 25.3%, 58.9%, and 15.8% of nodules, respectively. There were 200 patients with 265 nodules in the study set. Nineteen physicians scored the malignancy potential of the nodules. The average area under the curve (AUC) of all readers was 0.728 without CAD and significantly increased to 0.792 with CAD. The average standard deviation of the malignant potential score significantly decreased from 18.97 to 16.29. The mean malignant potential score significantly decreased from 35.01 to 31.24 for benign cases. With the CAD system, an additional 7.6% of malignant nodules would be suggested for further evaluation, and biopsy would not be recommended for an additional 10.8% of benign nodules. The results demonstrated that applying a CAD system would improve clinicians’ interpretations and lessen the variability in diagnosis. However, more studies are needed to explore the use of the CAD system in an actual ultrasound diagnostic situation where much more benign thyroid nodules would be seen.

27 April 2007 in International Journal of Production Research
Verified
Journal Article
Closed access
ACArgon Chen
Argon Chen
CHC.-H. Hsu
C.-H. Hsu
JBJ. Blue
J. Blue
Results of demand planning serve as the basis of every planning activity in a demand–supply network and ultimately determine the effectiveness of manufacturing and logistic planning, such as capacity and safety stock planning, in the network. The uncertainty of demand signals that are propagated and magnified over the network becomes the crucial cause of ineffective operation plans. With the globalization of demand–supply networks and the desire for a more integrated operation plan, demand planning is now one of the greatest challenges facing manufacturers. To manage the demand variability, appropriate demand aggregation and statistical forecasting approaches are known to be effective. This paper will use the bivariate VAR(1) time-series model as a study vehicle to investigate the effects of aggregating two interrelated demands. It is shown that the aggregated time series of two VAR(1) times series is equivalent to the sum of two AR(1) time series. Through theoretical development, the paper further explores the properties of the aggregated time series and provides guidelines for practitioners to determine proper aggregation and forecasting approaches. An important finding of this research is that demand aggregation is far more effective than statistical forecasting in operations planning for any two demands with low positive correlation or negative correlation.