We propose a novel contactless ultrasonic method for monitoring the hardening behavior of cementitious materials. The goal of this method is to obtain high-quality data to compare the unique hardening process between rapid setting cement (RSC) and ordinary Portland cement (OPC) mortars without physical coupling to the surface of the specimens. To monitor the hardening behavior of cementitious materials, conventional approaches use contact or embedded-type sensors, which limit field application. Our solution is to measure leaky Rayleigh waves at the interface between air and cementitious materials, which allows for the estimation of the physical state of the medium in real time. The modulus development was back-calculated based on the increment of wave velocity using the developed sensor array and transform-based signal processing. We experimentally demonstrated that the proposed method possibly exhibits unique hardening information about flash setting, effects of a retarder, and modulus increments from RSC specimens.
Soil moisture has been considered a key variable in governing the terrestrial ecosystem. However, it is challenging to preserve indigenous soil characteristics using conventional soil moisture monitoring methods that require maximum soil contacts. To overcome this issue, we developed a non-destructive method of evaluating soil moisture using a contactless ultrasonic system. This system was designed to measure leaky Rayleigh waves at the air–soil joint-half space. The influences of soil moisture on leaky Rayleigh waves were explored under sand, silt, and clay in a controlled experimental design. Our results showed that there were strong relationships between the energy and amplitude of leaky Rayleigh waves and soil moisture for all three soil cases. These results can be explained by reduced soil strengths during evaporation processes for coarse soil particles as opposed to fine soil particles. To evaluate soil moisture based on the dynamic parameters and wave properties obtained from the observed leaky Rayleigh waves, we used the random forest model. The accuracy of predicted soil moisture was exceptional for test data sets under all soil types (R ≥ 0.98, RMSE ≤ 0.0089 m m). That is, our study demonstrated that the leaky Rayleigh waves had great potential to continuously assess soil moisture variations without soil disturbances.
Prestressed concrete (PSC) is widely used for the construction of bridges. The collapse of several bridges with PSC has been reported, and insufficient grout and tendon corrosion were found inside the ducts of these bridges. Therefore, non-destructive testing (NDT) technology is important for identifying defects inside ducts in PSC structures. Electromagnetic (EM) waves have limited detection of internal defects in ducts due to strong reflections from the surface of the steel ducts. Spectral analysis of the existing impact echo (IE) method is limited to specific conditions. Moreover, the flexural mode in upper defects of ducts located at a shallow depth and delamination defects inside ducts are not considered. In this study, the applicability of the elastic wave of IE was analyzed, and multichannel analysis of surface, EM, and shear waves was employed to evaluate six types of PSC structures. A procedure using EM waves, IE, and principal component analysis (PCA) was proposed for a more accurate classification of defect types inside ducts. The proposed procedure was effective in classifying upper, internal, and delamination defects of ducts under 100 mm in thickness, and it could be utilized up to 200 mm in the case of duct defect limitations.
In this study, we present a method to estimate the depth of near-surface shallow delamination in concrete using a noncontact micro-electromechanical system (MEMS) ultrasonic sensor array and an optimization-based data processing approach. The proposed approach updates the bulk wave velocities of the tested concrete element by solving an optimization problem using reference ultrasonic scanning data collected from a full-depth concrete region. Subsequently, the depth of concrete delamination is estimated by solving a separate optimization problem. Numerical simulations and laboratory experiments were conducted to evaluate the performance of the proposed ultrasonic data processing approach. The results demonstrated that the depth of shallow delamination in concrete structures could be accurately estimated.
24 February 2023 in International Journal of Concrete Structures and Materials
The seismic performance of a concrete column retrofitted with an iron-based shape memory alloy (Fe-SMA) was evaluated under cyclic loading. In addition to structural behavior, internal damage was monitored using an ultrasonic pulse velocity test. The round shapes of three reinforced concrete (RC) columns were tested: a non-retrofitted RC column as a control, a carbon fiber-reinforced polymer (CFRP) column, and an Fe-SMA retrofitted column. During the cyclic loading test, the degradation of the column was defined based on the decrease in compressional wave velocities. The experimental results demonstrated a maximum improvement of 175% in seismic performance of the Fe-SMA retrofitted RC column compared with the controlled column. This is primarily owing to the active constraints of the SMA, which were quantified based on ultrasonic velocities. Furthermore, the surface degradation process was identified using external cracks, which were not visible in the CFRP retrofitted RC column.