Shoumen Datta

Dr. Shoumen Datta

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2007 in Journal of the Operational Research Society
Verified
Journal Article
Closed access
SDShoumen Datta
Shoumen Datta
CGC W J Granger
C W J Granger
MBM Barari
M Barari
TGT Gibbs
T Gibbs
Journal of the Operational Research Society (JORS) is the world's longest established OR journal and an official journal of The OR Society. It is the aim of the Journal to present papers which are relevant to practitioners, researchers, teachers, students and consumers of operational research, and which cover the theory, practice, history or methodology of OR.

1 April 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Eric McLamoreEric McLamore
Eric McLamore
Evangelyn AlociljaEvangelyn Alocilja
Evangelyn Alocilja
Carmen GomesCarmen Gomes
Carmen Gomes
Sundaram GunaekaranSundaram Gunaekaran
Sundaram Gunaekaran
DJDaniel Jenkins
Daniel Jenkins
AZAnhong Zhou
Anhong Zhou

30 June 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
YTYifan Tang
Yifan Tang
Geisianny A.M. MoreiraGeisianny A.M. Moreira
Geisianny A.M. Moreira
DVDiana Vanegas
Diana Vanegas
SDShoumen Datta
Shoumen Datta
Eric McLamoreEric McLamore
Eric McLamore
Laser-inscribed graphene (LIG) is an emerging material for micro-electronic applications and is being used to develop supercapacitors, soft actuators, triboelectric generators, and sensors. The fabrication technique is simple, yet the batch-to-batch variation of LIG quality is not well documented in the literature. In this study, we conduct experiments to characterize batch-to-batch variation in the manufacturing of LIG electrodes for applications in electrochemical sensing. Numerous batches of 36 LIG electrodes were synthesized using a CO2 laser system on polyimide film. The LIG material was characterized using goniometry, stereomicroscopy, open circuit potentiometry, and cyclic voltammetry. Hydrophobicity and electrochemical screening (cyclic voltammetry) indicate that LIG electrode batch-to-batch variation is less than 5% when using a commercial reference and counter electrode. Metallization of LIG led to a significant increase in peak current and specific capacitance (area between anodic/cathodic curve). However, batch-to-batch variation increased to approximately 30%. Two different platinum electrodeposition techniques were studied, including galvanostatic and frequency-modulated electrodeposition. The study shows that formation of metallized LIG electrodes with high specific capacitance and peak current may come at the expense of high batch variability. This design tradeoff has not been discussed in the literature and is an important consideration if scaling sensor designs for mass use is desired. This study provides important insight into the variation of LIG material properties for scalable development of LIG sensors. Additional studies are needed to understand the underlying mechanism(s) of this variability so that strategies to improve the repeatability may be developed for improving quality control. The dataset from this study is available via an open access repository.

13 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Eric McLamoreEric McLamore
Eric McLamore
SDShoumen Datta
Shoumen Datta
VMVictoria Morgan
Victoria Morgan
NCNicholas Cavallaro
Nicholas Cavallaro
GKGregory Kiker
Gregory Kiker
Evangelyn AlociljaEvangelyn Alocilja
Evangelyn Alocilja
In this review, we discuss the role of sensor analytics point solutions (SNAPS), a reduced complexity machine-assisted decision support tool. We summarize the approaches used for mobile phone-based chemical/biological sensors, including general hardware and software requirements for signal transduction and acquisition. We introduce SNAPS, part of a platform approach to converge sensor data and analytics. The platform is designed to consist of a portfolio of modular tools which may lend itself to dynamic composability by enabling context-specific selection of relevant units, resulting in case-based working modules. SNAPS is an element of this platform where data analytics, statistical characterization and algorithms may be delivered to the data either via embedded systems in devices, or sourced, in near real-time, from mist, fog or cloud computing resources. Convergence of the physical systems with the cyber components paves the path for SNAPS to progress to higher levels of artificial reasoning tools (ART) and emerge as data-informed decision support, as a service for general societal needs. Proof of concept examples of SNAPS are demonstrated both for quantitative data and qualitative data, each operated using a mobile device (smartphone or tablet) for data acquisition and analytics. We discuss the challenges and opportunities for SNAPS, centered around the value to users/stakeholders and the key performance indicators users may find helpful, for these types of machine-assisted tools.

23 December 2020 in Actuators
Verified
Journal Article
Open access
PDF file
CGCassie A. Giacobassi
Cassie A. Giacobassi
DODaniela A. Oliveira
Daniela A. Oliveira
CPCicero C. Pola
Cicero C. Pola
DXDong Xiang
Dong Xiang
YTYifan Tang
Yifan Tang
Carmen GomesCarmen Gomes
Carmen Gomes
Foodborne pathogens are a major concern for public health. We demonstrate for the first time a partially automated sensing system for rapid (~17 min), label-free impedimetric detection of Escherichia coli spp. in food samples (vegetable broth) and hydroponic media (aeroponic lettuce system) based on temperature-responsive poly(N-isopropylacrylamide) (PNIPAAm) nanobrushes. This proof of concept (PoC) for the Sense-Analyze-Respond-Actuate (SARA) paradigm uses a biomimetic nanostructure that is analyzed and actuated with a smartphone. The bio-inspired soft material and sensing mechanism is inspired by binary symbiotic systems found in nature, where low concentrations of bacteria are captured from complex matrices by brush actuation driven by concentration gradients at the tissue surface. To mimic this natural actuation system, carbon-metal nanohybrid sensors were fabricated as the transducer layer, and coated with PNIPAAm nanobrushes. The most effective coating and actuation protocol for E. coli detection at various temperatures above/below the critical solution temperature of PNIPAAm was determined using a series of electrochemical experiments. After analyzing nanobrush actuation in stagnant media, we developed a flow through system using a series of pumps that are triggered by electrochemical events at the surface of the biosensor. SARA PoC may be viewed as a cyber-physical system that actuates nanomaterials using smartphone-based electroanalytical testing of samples. This study demonstrates thermal actuation of polymer nanobrushes to detect (sense) bacteria using a cyber-physical systems (CPS) approach. This PoC may catalyze the development of smart sensors capable of actuation at the nanoscale (stimulus-response polymer) and macroscale (non-microfluidic pumping).

29 October 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
SUSadia Ullah
Sadia Ullah
Geisianny A.M. MoreiraGeisianny A.M. Moreira
Geisianny A.M. Moreira
SDShoumen Datta
Shoumen Datta
Eric McLamoreEric McLamore
Eric McLamore
DVDiana Vanegas
Diana Vanegas
Biolayer interferometry (BLI) is a well-established laboratory technique for studying biomolecular interactions important for applications such as drug development. Currently, there are interesting opportunities for expanding the use of BLI in other fields, including the development of rapid diagnostic tools. To date, there are no detailed frameworks for implementing BLI in target-recognition studies that are pivotal for developing point-of-need biosensors. Here, we attempt to bridge these domains by providing a framework that connects output(s) of molecular interaction studies with key performance indicators used in the development of point-of-need biosensors. First, we briefly review the governing theory for protein-ligand interactions, and we then summarize the approach for real-time kinetic quantification using various techniques. The 2020 PRISMA guideline was used for all governing theory reviews and meta-analyses. Using the information from the meta-analysis, we introduce an experimental framework for connecting outcomes from BLI experiments (KD, kon, koff) with electrochemical (capacitive) biosensor design. As a first step in the development of a larger framework, we specifically focus on mapping BLI outcomes to five biosensor key performance indicators (sensitivity, selectivity, response time, hysteresis, operating range). The applicability of our framework was demonstrated in a study of case based on published literature related to SARS-CoV-2 spike protein to show the development of a capacitive biosensor based on truncated angiotensin-converting enzyme 2 (ACE2) as the receptor. The case study focuses on non-specific binding and selectivity as research goals. The proposed framework proved to be an important first step toward modeling/simulation efforts that map molecular interactions to sensor design.